JOSÉ ANTONIO CALVO HARO

Dr. JOSÉ ANTONIO CALVO HARO

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 February 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Rafael Moreta-MartinezRafael Moreta-Martinez
Rafael Moreta-Martinez
Alicia Pose Díez de la LastraAlicia Pose Díez de la Lastra
Alicia Pose Díez de la Lastra
JHJOSÉ ANTONIO CALVO HARO
JOSÉ ANTONIO CALVO HARO
LMLydia Mediavilla
Lydia Mediavilla
RPRubén Pérez-Mañanes
Rubén Pérez-Mañanes
Javier PascauJavier Pascau
Javier Pascau
During the last decade, orthopedic oncology has experienced the benefits of computerized medical imaging to reduce human dependency, improving accuracy and clinical outcomes. However, traditional surgical navigation systems do not always adapt properly to this kind of interventions. Augmented reality (AR) and three-dimensional (3D) printing are technologies lately introduced in the surgical environment with promising results. Here we present an innovative solution combining 3D printing and AR in orthopedic oncological surgery. A new surgical workflow is proposed, including 3D printed models and a novel AR-based smartphone application (app). This app can display the patient’s anatomy and the tumor’s location. A 3D-printed reference marker, designed to fit in a unique position of the affected bone tissue, enables automatic registration. The system has been evaluated in terms of visualization accuracy and usability during the whole surgical workflow. Experiments on six realistic phantoms provided a visualization error below 3 mm. The AR system was tested in two clinical cases during surgical planning, patient communication, and surgical intervention. These results and the positive feedback obtained from surgeons and patients suggest that the combination of AR and 3D printing can improve efficacy, accuracy, and patients’ experience.

29 June 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Alicia Pose Díez de la LastraAlicia Pose Díez de la Lastra
Alicia Pose Díez de la Lastra
Rafael Moreta-MartinezRafael Moreta-Martinez
Rafael Moreta-Martinez
Monica Garcia SevillaMonica Garcia Sevilla
Monica Garcia Sevilla
David García-MatoDavid García-Mato
David García-Mato
JHJOSÉ ANTONIO CALVO HARO
JOSÉ ANTONIO CALVO HARO
Javier PascauJavier Pascau
Javier Pascau
This work analyzed the use of Microsoft HoloLens 2 in orthopedic oncological surgeries and compares it to its predecessor (Microsoft HoloLens 1). Specifically, we developed two equivalent applications, one for each device, and evaluated the augmented reality (AR) projection accuracy in an experimental scenario using phantoms based on two patients. We achieved automatic registration between virtual and real worlds using patient-specific surgical guides on each phantom. They contained a small adaptor for a 3D-printed AR marker, the characteristic patterns of which were easily recognized using both Microsoft HoloLens devices. The newest model improved the AR projection accuracy by almost 25%, and both of them yielded an RMSE below 3 mm. After ascertaining the enhancement of the second model in this aspect, we went a step further with Microsoft HoloLens 2 and tested it during the surgical intervention of one of the patients. During this experience, we collected the surgeons’ feedback in terms of comfortability, usability, and ergonomics. Our goal was to estimate whether the improved technical features of the newest model facilitate its implementation in actual surgical scenarios. All of the results point to Microsoft HoloLens 2 being better in all the aspects affecting surgical interventions and support its use in future experiences.

22 April 2021 in 3D Printing in Medicine
Verified
Journal Article
Open access
PDF file
JHJOSÉ ANTONIO CALVO HARO
JOSÉ ANTONIO CALVO HARO
Javier PascauJavier Pascau
Javier Pascau
JAJosé Manuel Asencio-Pascual
José Manuel Asencio-Pascual
FCFelipe Calvo-Manuel
Felipe Calvo-Manuel
MCMaria José Cancho-Gil
Maria José Cancho-Gil
RPRubén Perez-Mañanes
Rubén Perez-Mañanes
Background: The integration of 3D printing technology in hospitals is evolving toward production models such as point-of-care manufacturing. This study aims to present the results of the integration of 3D printing technology in a manufacturing university hospital. Methods: Observational, descriptive, retrospective, and monocentric study of 907 instances of 3D printing from November 2015 to March 2020. Variables such as product type, utility, time, or manufacturing materials were analyzed. Results: Orthopedic Surgery and Traumatology, Oral and Maxillofacial Surgery, and Gynecology and Obstetrics are the medical specialties that have manufactured the largest number of processes. Working and printing time, as well as the amount of printing material, is different for different types of products and input data. The most common printing material was polylactic acid, although biocompatible resin was introduced to produce surgical guides. In addition, the hospital has worked on the co-design of custom-made implants with manufacturing companies and has also participated in tissue bio-printing projects. Conclusions: The integration of 3D printing in a university hospital allows identifying the conceptual evolution to “point-of-care manufacturing.”

24 November 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Monica Garcia SevillaMonica Garcia Sevilla
Monica Garcia Sevilla
Rafael Moreta-MartinezRafael Moreta-Martinez
Rafael Moreta-Martinez
David García-MatoDavid García-Mato
David García-Mato
Alicia Pose Díez de la LastraAlicia Pose Díez de la Lastra
Alicia Pose Díez de la Lastra
RPRubén Pérez-Mañanes
Rubén Pérez-Mañanes
Javier PascauJavier Pascau
Javier Pascau
Patient-specific instruments (PSIs) have become a valuable tool for osteotomy guidance in complex surgical scenarios such as pelvic tumor resection. They provide similar accuracy to surgical navigation systems but are generally more convenient and faster. However, their correct placement can become challenging in some anatomical regions, and it cannot be verified objectively during the intervention. Incorrect installations can result in high deviations from the planned osteotomy, increasing the risk of positive resection margins. In this work, we propose to use augmented reality (AR) to guide and verify PSIs placement. We designed an experiment to assess the accuracy provided by the system using a smartphone and the HoloLens 2 and compared the results with the conventional freehand method. The results showed significant differences, where AR guidance prevented high osteotomy deviations, reducing maximal deviation of 54.03 mm for freehand placements to less than 5 mm with AR guidance. The experiment was performed in two versions of a plastic three-dimensional (3D) printed phantom, one including a silicone layer to simulate tissue, providing more realism. We also studied how differences in shape and location of PSIs affect their accuracy, concluding that those with smaller sizes and a homogeneous target surface are more prone to errors. Our study presents promising results that prove AR’s potential to overcome the present limitations of PSIs conveniently and effectively.

22 February 2021 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Closed access
PDF file
Monica Garcia SevillaMonica Garcia Sevilla
Monica Garcia Sevilla
LMLydia Mediavilla-Santos
Lydia Mediavilla-Santos
MRMaría Teresa Ruiz-Alba
María Teresa Ruiz-Alba
RPRubén Pérez-Mañanes
Rubén Pérez-Mañanes
JHJOSÉ ANTONIO CALVO HARO
JOSÉ ANTONIO CALVO HARO
Javier PascauJavier Pascau
Javier Pascau

1 October 2010 in The Journal of Bone and Joint Surgery. British volume
Verified
Journal Article
Open access
PDF file
JVJ. Vaquero
J. Vaquero
JHJOSÉ ANTONIO CALVO HARO
JOSÉ ANTONIO CALVO HARO
FCF. Chana
F. Chana
RPR. Perez-Mañanes
R. Perez-Mañanes
Isolated patellofemoral osteoarthritis can be a disabling disease. When conservative treatment fails, surgical options can be unpredictable and may be considered too aggressive for middle-aged and active people. We analysed the clinical and radiological results of a new coronal osteotomy involving thinning of the patella in a selected group of patients with isolated patellofemoral osteoarthritis. Since 1991, 31 patients (35 knees) have been treated, of whom 34 were available for follow-up at a mean of 9.1 years. The Knee Society Score, the Patellar score and the Short-form-36 questionnaire were used for clinical evaluation. We also examined the radiological features to confirm bone consolidation and assess the progression of osteoarthritis. A significant improvement in the functional scores and radiological parameters was noted. All patients except one were satisfied with the operation. Radiological progression of the patellofemoral osteoarthritis was slowed but radiological femorotibial osteoarthritis progressed in 23 (65%) cases, with a total knee replacement becoming necessary in four cases without technical problems in resurfacing the patella. We compared the results with other forms of surgical treatment reported in the literature. This treatment offers good clinical and radiological results, presenting an alternative method of managing patellofemoral osteoarthritis.