The management of anterior cruciate ligament (ACL) injuries in pediatric patients presents unique challenges due to the presence of open growth plates in the proximal tibia and distal femur. Delaying ACL reconstruction until skeletal maturity may protect the physes but increases the risk of secondary injuries, such as meniscal tears and chondral damage, due to prolonged joint instability. Conversely, early surgical intervention restores knee stability but raises concerns about potential growth disturbances, including leg-length discrepancies and angular deformities. This narrative review examines current approaches to pediatric ACL management, highlighting the risks and benefits of both conservative and surgical treatments. Additionally, it explores the role of finite element modeling (FEM) as an innovative tool for pre-surgical planning. FEM offers a non-invasive method to optimize surgical techniques, minimize iatrogenic damage to growth plates, and improve patient outcomes. Despite its potential, FEM remains underutilized in clinical practice. This review underscores the need to integrate FEM into pediatric ACL care to enhance surgical precision, reduce complications, and improve long-term quality of life for young patients. By synthesizing available evidence, this review aims to provide clinicians with a comprehensive framework for decision-making and identify future directions for research in pediatric ACL reconstruction.
Purpose: To compare the outcomes of three sequential surgical techniques used over time for posterior spinal fusion (PSF) in adolescent idiopathic scoliosis (AIS) patients with Lenke 1 & 2 curves. Methods: Three sequential cohorts of Lenke 1 & 2 AIS patients who underwent PSF between 2008 and 2021 were retrospectively identified. Surgical technique, including concave rod derotation (T1), concave en bloc reduction (T2), or convex-first differential rod contouring technique (T3), was recorded. Preoperative, intraoperative, and minimum 2-year postoperative variables were compared. Results: Ninety-three Lenke 1 & 2 AIS patients were evaluated: 30 T1, 25 T2, and 38 T3. No significant differences were noted in demographics or preoperative radiographic measurements. The T3 group utilized higher implant density and more posterior column osteotomies (PCOs). Postoperatively, there was equivalent coronal correction index in all three cohorts. T3 resulted in significantly improved sagittal plane parameters, including final T5-T12 kyphosis (16.8° vs. 13.3° vs. 20.8° p = 0.011), final T2-T12 kyphosis (19.9° vs. 18.8°, 27.0° p = 0.033), delta T2-T12 kyphosis (-1.0° vs. -6.7° vs.1.5° p = 0.005), and delta 3D kyphosis (14.1° vs. 10.5° vs. 15.8° p = 0.034). Significant covariates of postoperative T5-T12 kyphosis included preoperative 3D kyphosis ( p = < 0.001) and number of PCOs ( p = 0.002). There were no differences in complications, readmissions, or unplanned reoperations. Conclusion: Practice evolution using a recent technique, specifically the convex-first differential rod reduction technique (T3), results in superior restoration of thoracic kyphosis compared to older concave rod derotation (T1) or concave en bloc reduction (T2) techniques for Lenke 1 & 2 AIS patients.
1 July 2025 in JPO Journal of Prosthetics and Orthotics
Introduction: Functional anterior cruciate ligament (ACL) orthoses protect the knee from further injury by preventing anterior tibial translation and valgus moments at the joint. Through contact loading, the anterior tibial pads on the orthosis provide a posteriorly directed force to minimize anterior strain to the healing ACL graft. Objective: The purpose of this study was to determine how effective custom functional ACL bracing is in preventing anterior tibial translation. Study Design: Observational study. Methods: The contact pressures of custom ACL orthoses exerted along the tibia were replicated in 22 patient-specific pediatric finite element models. Previously developed, nonbracing knee models that have been validated in accurately predicting anterior tibial translation were utilized to determine how effective this orthosis design is in preventing anterior joint translations when subject to Lachman and pivot shift test loading conditions. Results: For the Lachman test, the anterior tibial translations decreased from 5.53 mm, 6.53 mm, and 7.54 mm to 4.82 mm, 5.60 mm, and 6.58 mm. The pivot shift test experienced a decrease from 4.38 mm to 3.64 mm when the anterior tibial pad contact loads were applied to the models. The custom ACL knee orthosis provides a significant (P < 0.05) resistance to anterior tibial translation compared with the nonbracing models for both loading conditions. Conclusions: The utilization of finite element technology makes it possible to assess knee orthosis biomechanics in a manner that is difficult or cannot be assessed in a clinical setting. Custom functional ACL knee orthoses provide a significant resistance to anterior tibial displacement. Clinical Relevance Statement: Understanding the biomechanical impact knee orthoses have in protecting the healing ACL graft can provide clinicians with the opportunity to prescribe the best orthosis that will significantly minimize the risk of reinjury and improve patient outcomes and quality of life.