A capacitor voltage balancing method is proposed for a full-bridge neutral point diode clamped (NPC) dual active bridge (DAB) converter. In existing literature, capacitor voltage balancing is achieved by actively selecting between the small voltage vectors, i.e., connecting either the upper or the lower capacitor on the DC bus to the transformer winding, based on the measured capacitor voltage mismatch. These balancing methods are dependent on the direction of power flow through the DAB converter. In this work, we propose a voltage balancing controller which is independent of power flow direction and does not require adjustments of active voltage vectors through the modulator. Irrespective of the direction of transformer current, by dynamically shifting the switching instants of the inner switch pairs in the two NPC legs during the free-wheeling/zero voltage vector time, either of the two capacitors can be selectively charged without introducing any offsets in the voltage-second seen by the transformer. A simple bi-directional phase shift modulator is designed to facilitate voltage balancing irrespective of power flow direction or mode of operation. The proposed voltage balancing method is highly and universally effective under any converter operating condition and was verified and demonstrated through analysis, simulation, and hardware experiments using a laboratory prototype.
The control of medium-voltage cascaded H-bridge (CHB) converters demands precise, high-bandwidth, low-latency, and isolated measurements. Traditional analog-to-digital converters (ADCs) can facilitate multisampling methods to meet these requirements but do not provide the high-voltage galvanic isolation that may be necessary in a system operating at medium voltage. Sigma-Delta ADCs (SD-ADCs) present a promising alternative due to their superior noise rejection capabilities and direct integration with the optical fiber interface. However, the inherent latency associated with SD-ADCs, stemming from their operating principles, poses challenges when integrating them with multisampling methods. This paper analyzes the integration of multisampling techniques with SD-ADCs for medium-voltage CHB converter control. First, the impact of SD-ADC-induced delays on the control system is elucidated from the passivity perspective. Second, the practical implementation of multisampling with SD-ADCs is discussed in detail. Finally, experimental results from a 2400 Vrms medium-voltage CHB converter are presented to validate the analysis and illustrate the effectiveness of the proposed implementation.