Christopher Hutengs

Mr. Christopher Hutengs


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 March 2018 in Sensors
Verified
Journal Article
Open access
PDF file
CHChristopher Hutengs
Christopher Hutengs
BLBernard Ludwig
Bernard Ludwig
András JungAndrás Jung
András Jung
AEAndreas Eisele
Andreas Eisele
Michael VohlandMichael Vohland
Michael Vohland
Mid-infrared (MIR) spectroscopy has received widespread interest as a method to complement traditional soil analysis. Recently available portable MIR spectrometers additionally offer potential for on-site applications, given sufficient spectral data quality. We therefore tested the performance of the Agilent 4300 Handheld FTIR (DRIFT spectra) in comparison to a Bruker Tensor 27 bench-top instrument in terms of (i) spectral quality and measurement noise quantified by wavelet analysis; (ii) accuracy of partial least squares (PLS) calibrations for soil organic carbon (SOC), total nitrogen (N), pH, clay and sand content with a repeated cross-validation analysis; and (iii) key spectral regions for these soil properties identified with a Monte Carlo spectral variable selection approach. Measurements and multivariate calibrations with the handheld device were as good as or slightly better than Bruker equipped with a DRIFT accessory, but not as accurate as with directional hemispherical reflectance (DHR) data collected with an integrating sphere. Variations in noise did not markedly affect the accuracy of multivariate PLS calibrations. Identified key spectral regions for PLS calibrations provided a good match between Agilent and Bruker DHR data, especially for SOC and N. Our findings suggest that portable FTIR instruments are a viable alternative for MIR measurements in the laboratory and offer great potential for on-site applications.

3 January 2021 in Remote Sensing
Verified
Journal Article
Open access
PDF file
RRRonny Richter
Ronny Richter
CHChristopher Hutengs
Christopher Hutengs
CWChristian Wirth
Christian Wirth
LBLutz Bannehr
Lutz Bannehr
Michael VohlandMichael Vohland
Michael Vohland
Canopy temperatures are important for understanding tree physiology, ecology, and their cooling potential, which provides a valuable ecosystem service, especially in urban environments. Linkages between tree species composition in forest stands and air temperatures remain challenging to quantify, as the establishment and maintenance of onsite sensor networks is time-consuming and costly. Remotely-sensed land surface temperature (LST) observations can potentially acquire spatially distributed crown temperature data more efficiently. We analyzed how tree species modify canopy air temperature at an urban floodplain forest (Leipzig, Germany) site equipped with a detailed onsite sensor network, and explored whether mono-temporal thermal remote sensing observations (August, 2016) at different spatial scales could be used to model air temperatures at the tree crown level. Based on the sensor-network data, we found interspecific differences in summer air temperature to vary temporally and spatially, with mean differences between coldest and warmest tree species of 1 °C, and reaching maxima of up to 4 °C for the upper and lower canopy region. The detectability of species-specific differences in canopy surface temperature was found to be similarly feasible when comparing high-resolution airborne LST data to the airborne LST data aggregated to 30 m pixel size. To realize a spatial resolution of 30 m with regularly acquired data, we found the downscaling of Landsat 8 thermal data to be a valid alternative to airborne data, although detected between-species differences in surface temperature were less expressed. For the modeling of canopy air temperatures, all LST data up to the 30 m level were similarly appropriate. We thus conclude that satellite-derived LST products could be recommended for operational use to detect and monitor tree species effects on temperature regulation at the crown scale.

10 February 2022 in Remote Sensing
Verified
Journal Article
Open access
PDF file
FSFabian Sittaro
Fabian Sittaro
CHChristopher Hutengs
Christopher Hutengs
SSSebastian Semella
Sebastian Semella
Michael VohlandMichael Vohland
Michael Vohland
Anthropogenic climate and land use change is causing rapid shifts in the distribution and composition of habitats with profound impacts on ecosystem biodiversity. The sustainable management of ecosystems requires monitoring programmes capable of detecting shifts in habitat distribution and composition at large spatial scales. Remote sensing observations facilitate such efforts as they enable cost-efficient modelling approaches that utilize publicly available datasets and can assess the status of habitats over extended periods of time. In this study, we introduce a modelling framework for habitat monitoring in Germany using readily available MODIS surface reflectance data. We developed supervised classification models that allocate (semi-)natural areas to one of 18 classes based on their similarity to Natura 2000 habitat types. Three machine learning classifiers, i.e., Support Vector Machines (SVM), Random Forests (RF), and C5.0, and an ensemble approach were employed to predict habitat type using spectral signatures from MODIS in the visible-to-near-infrared and short-wave infrared. The models were trained on homogenous Special Areas of Conservation that are predominantly covered by a single habitat type with reference data from 2013, 2014, and 2016 and tested against ground truth data from 2010 and 2019 for independent model validation. Individually, the SVM and RF methods achieved better overall classification accuracies (SVM: 0.72–0.93%, RF: 0.72–0.94%) than the C5.0 algorithm (0.66–0.93%), while the ensemble classifier developed from the individual models gave the best performance with overall accuracies of 94.23% for 2010 and 80.34% for 2019 and also allowed a robust detection of non-classifiable pixels. We detected strong variability in the cover of individual habitat types, which were reduced when aggregated based on their similarity. Our methodology is capable to provide quantitative information on the spatial distribution of habitats, differentiate between disturbance events and gradual shifts in ecosystem composition, and could successfully allocate natural areas to Natura 2000 habitat types.

6 January 2023 in Sensors
Verified
Journal Article
Open access
PDF file
IGIsabel Greenberg
Isabel Greenberg
Michael VohlandMichael Vohland
Michael Vohland
MSMichael Seidel
Michael Seidel
CHChristopher Hutengs
Christopher Hutengs
RBRachel Bezard
Rachel Bezard
BLBernard Ludwig
Bernard Ludwig
Previous studies investigating multi-sensor fusion for the collection of soil information have shown variable improvements, and the underlying prediction mechanisms are not sufficiently understood for spectrally-active and -inactive properties. Our objective was to study prediction mechanisms and benefits of model fusion by measuring mid-infrared (MIR) and X-ray fluorescence (XRF) spectra, texture, total and labile organic carbon (OC) and nitrogen (N) content, pH, and cation exchange capacity (CEC) for n = 117 soils from an arable field in Germany. Partial least squares regression models underwent a three-fold training/testing procedure using MIR spectra or elemental concentrations derived from XRF spectra. Additionally, two sequential hybrid and two high-level fusion approaches were tested. For the studied field, MIR was superior for organic properties (ratio of prediction to interquartile distance of validation (RPIQV) for total OC = 7.7 and N = 5.0)), while XRF was superior for inorganic properties (RPIQV for clay = 3.4, silt = 3.0, and sand = 1.8). Even the optimal fusion approach brought little to no accuracy improvement for these properties. The high XRF accuracy for clay and silt is explained by the large number of elements with variable importance in the projection scores >1 (Fe ≈ Ni > Si ≈ Al ≈ Mg > Mn ≈ K ≈ Pb (clay only) ≈ Cr) with strong spearman correlations (±0.57 < rs < ±0.90) with clay and silt. For spectrally-inactive properties relying on indirect prediction mechanisms, the relative improvements from the optimal fusion approach compared to the best single spectrometer were marginal for pH (3.2% increase in RPIQV versus MIR alone) but more pronounced for labile OC (9.3% versus MIR) and CEC (12% versus XRF). Dominance of a suboptimal spectrometer in a fusion approach worsened performance compared to the best single spectrometer. Granger-Ramanathan averaging, which weights predictions according to accuracy in training, is therefore recommended as a robust approach to capturing the potential benefits of multiple sensors.

2 April 2022 in Sensors
Verified
Journal Article
Open access
PDF file
SSSebastian Semella
Sebastian Semella
CHChristopher Hutengs
Christopher Hutengs
MSMichael Seidel
Michael Seidel
MUMathias Ulrich
Mathias Ulrich
BSBirgit Schneider
Birgit Schneider
Michael VohlandMichael Vohland
Michael Vohland
Soil spectroscopy in the visible-to-near infrared (VNIR) and mid-infrared (MIR) is a cost-effective method to determine the soil organic carbon content (SOC) based on predictive spectral models calibrated to analytical-determined SOC reference data. The degree to which uncertainty in reference data and spectral measurements contributes to the estimated accuracy of VNIR and MIR predictions, however, is rarely addressed and remains unclear, in particular for current handheld MIR spectrometers. We thus evaluated the reproducibility of both the spectral reflectance measurements with portable VNIR and MIR spectrometers and the analytical dry combustion SOC reference method, with the aim to assess how varying spectral inputs and reference values impact the calibration and validation of predictive VNIR and MIR models. Soil reflectance spectra and SOC were measured in triplicate, the latter by different laboratories, for a set of 75 finely ground soil samples covering a wide range of parent materials and SOC contents. Predictive partial least-squares regression (PLSR) models were evaluated in a repeated, nested cross-validation approach with systematically varied spectral inputs and reference data, respectively. We found that SOC predictions from both VNIR and MIR spectra were equally highly reproducible on average and similar to the dry combustion method, but MIR spectra were more robust to calibration sample variation. The contributions of spectral variation (ΔRMSE < 0.4 g·kg−1) and reference SOC uncertainty (ΔRMSE < 0.3 g·kg−1) to spectral modeling errors were small compared to the difference between the VNIR and MIR spectral ranges (ΔRMSE ~1.4 g·kg−1 in favor of MIR). For reference SOC, uncertainty was limited to the case of biased reference data appearing in either the calibration or validation. Given better predictive accuracy, comparable spectral reproducibility and greater robustness against calibration sample selection, the portable MIR spectrometer was considered overall superior to the VNIR instrument for SOC analysis. Our results further indicate that random errors in SOC reference values are effectively compensated for during model calibration, while biased SOC calibration data propagates errors into model predictions. Reference data uncertainty is thus more likely to negatively impact the estimated validation accuracy in soil spectroscopy studies where archived data, e.g., from soil spectral libraries, are used for model building, but it should be negligible otherwise.

29 May 2020 in Remote Sensing
Verified
Journal Article
Open access
PDF file
MSMichael Seidel
Michael Seidel
CHChristopher Hutengs
Christopher Hutengs
FOFelix Oertel
Felix Oertel
DSDaniel Schwefel
Daniel Schwefel
András JungAndrás Jung
András Jung
Michael VohlandMichael Vohland
Michael Vohland
Freshwater lakes provide many important ecosystem functions and services to support biodiversity and human well-being. Proximal and remote sensing methods represent an efficient approach to derive water quality indicators such as optically active substances (OAS). Measurements of above-ground remote and in situ proximal sensors, however, are limited to observations of the uppermost water layer. We tested a hyperspectral imaging system, customized for underwater applications, with the aim to assess concentrations of chlorophyll a (CHLa) and colored dissolved organic matter (CDOM) in the water columns of four freshwater lakes with different trophic conditions in Central Germany. We established a measurement protocol that allowed consistent reflectance retrievals at multiple depths within the water column independent of ambient illumination conditions. Imaging information from the camera proved beneficial for an optimized extraction of spectral information since low signal areas in the sensor’s field of view, e.g., due to non-uniform illumination, and other interfering elements, could be removed from the measured reflectance signal for each layer. Predictive hyperspectral models, based on the 470 nm–850 nm reflectance signal, yielded estimates of both water quality parameters (R² = 0.94, RMSE = 8.9 µg L−1 for CHLa; R² = 0.75, RMSE = 0.22 m−1 for CDOM) that were more accurate than commonly applied waveband indices (R² = 0.83, RMSE = 13.2 µg L−1 for CHLa; R² = 0.66, RMSE = 0.25 m−1 for CDOM). Underwater hyperspectral imaging could thus facilitate future water monitoring efforts through the acquisition of consistent spectral reflectance measurements or derived water quality parameters along the water column, which has the potential to improve the link between above-surface proximal and remote sensing observations and in situ point-based water probe measurements for ground truthing or to resolve the vertical distribution of OAS.