In this work, chaos game optimization (CGO), a robust optimization approach, is employed for efficient design of a novel cascade controller for four test systems with interconnected power systems (IPSs) to tackle load–frequency control (LFC) difficulties. The CGO method is based on chaos theory principles, in which the structure of fractals is seen via the chaotic game principle and the fractals’ self-similarity characteristics are considered. CGO is applied in LFC studies as a novel application, which reveals further research gaps to be filled. For practical implementation, it is also highly desirable to keep the controller structure simple. Accordingly, in this paper, a CGO-based controller of fractional-order (FO) proportional–integral–derivative–FO proportional–integral (FOPID–FOPI) controller is proposed, and the integral time multiplied absolute error performance function is used. Initially, the proposed CGO-based FOPID–FOPI controller is tested with and without the nonlinearity of the governor dead band for a two-area two-source model of a non-reheat unit. This is a common test system in the literature. A two-area multi-unit system with reheater–hydro–gas in both areas is implemented. To further generalize the advantages of the proposed scheme, a model of a three-area hydrothermal IPS including generation rate constraint nonlinearity is employed. For each test system, comparisons with relevant existing studies are performed. These demonstrate the superiority of the proposed scheme in reducing settling time, and frequency and tie-line power deviations.
7 April 2021 in Journal of Electrical Engineering & Technology
This paper suggests a fuzzy logic controller (FLC) structure from seven membership functions (MFs) and its input–output relationship rules to design a secondary controller to reduce load frequency control (LFC) issues. The FLC is coupled to a proportional–integral–derivative (PID) controller as the proposed FPID controller, which is tuned by an optimized water cycle algorithm (WCA). The proposed WCA: FPID scheme was implemented with two models from the literature under the integral time absolute error cost function. Initially, a two-area non-reheat unit was implemented, and the gains of PID and FPID controllers were adjusted to verify the suitability of WCA in solving LFC issues. Then, in order to identify the robustness of the closed-loop system, sensitivity analysis is carried out. Additionally, a two-area non-reheat unit was tested under the governor dead band nonlinearity. To guarantee the suitability of the proposed FPID controller, a model with a mixture of power plants, such as reheat, hydro, and gas unit in each area was carried out with and without the HVDC link, which can increase practical issues with LFC. The proposed controller's robustness was studied for all models under numerous scenarios, step load perturbations (SLP), and different objective functions. Simulation results proved that the proposed FPID controller provided superior performance compared to recently reported techniques in terms of peaks and settling time.
Automatic generation control (AGC) is essential for raising living standards because it enhances power supply quality. However, due to the constraints and challenges experienced in practice, an effective and computationally economical control method is necessary to improve AGC performance, particularly in the presence of renewable energy. Therefore, this study introduces a novel cascade controller (CC) of a proportional–integral–derivative (PIDn) controller followed by a proportional–integral (PI) controller, forming a PIDn-PI CC. This controller is used in a two-area model comprising a reheat thermal generator and a photovoltaic unit. The gains of the PI, PIDn, and PIDn-PI controllers are adjusted using the recently introduced chaos game optimization (CGO), which minimizes the objective function integral time multiplied absolute error. The CGO relies on chaos theory principals, wherein the organization of fractal geometry is perceived through the chaotic game and the fractals’ self-similarity properties are considered. At first, the CGO based PIDn controller is employed, to check the suitability of CGO in dealing with AGC problems. Furthermore, several scenarios are used to confirm the effectiveness of the CGO:PIDn-PI scheme when subjected to a high load disturbance and uncertainty, which can change system parameters by ± 50%. A random load pattern is used to ascertain the proposed method’s efficacy. Finally, nonlinearities, such as generation rate constraint and time delay, which have a significant impact on AGC performance, are considered. Compared with relevant current research, the suggested approach outperforms them in terms of settling time, frequency, and tie-line power deviations.
16 May 2022 in Process Integration and Optimization for Sustainability