Seung Won Kim

Prof. Seung Won Kim

Keimyung University, Daegu, Republic of Korea
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 April 2025 in Nanomaterials
Verified
Journal Article
Open access
PDF file
Shaik Gouse PeeraShaik Gouse Peera
Shaik Gouse Peera
Seung Won KimSeung Won Kim
Seung Won Kim
With unique 4f electronic shells, rare earth metal-based catalysts have been attracting tremendous attention in electrocatalysis, including oxygen reduction reaction (ORR). In particular, atomically dispersed Ce/CeO2-based catalysts have been explored extensively due to several unique features. This review article provides a comprehensive understanding of (i) the significance of the effect of Ce high-spin state on ORR activity enhancement on the Pt and non-pt electrocatalysts, (ii) the spatially confining and stabilizing effect of ceria on the generation of atomically dispersed transition metal-based catalysts, (iii) experimental and theoretical evidence of the effect of Ce3+ ↔ Ce4+ redox pain on radical scavenging, (iv) the effect of the Ce 4f electrons on the d-band center and electron transfer between Ce to the N-doped carbon and transition metal catalysts for enhanced ORR activity, and (v) the effect of Pt/CeO2/carbon heterojunctions on the stability of the Pt/CeO2/carbon electrocatalyst for ORR. Among several strategies of synthesizing Ce/CeO2 electrocatalysts, the metal–organic framework (MOF)-derived catalysts are being perused extensively due to the tendency of Ce to readily coordinate with O- and N-containing ligands, which upon undergoing pyrolysis, results in the formation of high surface area, porous carbon networks with atomically dispersed metallic/clusters/nanoparticles of Ce active sites. This review paper provides an overview of recent advancements regarding Ce/CeO2-based catalysts derived from the MOF precursor for ORR in fuel cells and metal–air battery applications and we conclude with insights into key issues and future development directions.

6 September 2006 in Journal of Environmental Monitoring
Verified
Journal Article
Closed access
PDF file
JFJames E. Farnsworth
James E. Farnsworth
SGSagar M. Goyal
Sagar M. Goyal
Seung Won KimSeung Won Kim
Seung Won Kim
TKThomas H. Kuehn
Thomas H. Kuehn
PRPeter C. Raynor
Peter C. Raynor
WTWeihua Tang
Weihua Tang
The aim of the work presented here is to study the effectiveness of building air handling units (AHUs) in serving as high volume sampling devices for airborne bacteria and viruses. An HVAC test facility constructed according to ASHRAE Standard 52.2-1999 was used for the controlled loading of HVAC filter media with aerosolized bacteria and virus. Nonpathogenic Bacillus subtilis var. niger was chosen as a surrogate for Bacillus anthracis. Three animal viruses; transmissible gastroenteritis virus (TGEV), avian pneumovirus (APV), and fowlpox virus were chosen as surrogates for three human viruses; SARS coronavirus, respiratory syncytial virus, and smallpox virus; respectively. These bacteria and viruses were nebulized in separate tests and injected into the test duct of the test facility upstream of a MERV 14 filter. SKC Biosamplers upstream and downstream of the test filter served as reference samplers. The collection efficiency of the filter media was calculated to be 96.5 ± 1.5% for B. subtilis, however no collection efficiency was measured for the viruses as no live virus was ever recovered from the downstream samplers. Filter samples were cut from the test filter and eluted by hand-shaking. An extraction efficiency of 105 ± 19% was calculated for B. subtilis. The viruses were extracted at much lower efficiencies (0.7–20%). Our results indicate that the airborne concentration of spore-forming bacteria in building AHUs may be determined by analyzing the material collected on HVAC filter media, however culture-based analytical techniques are impractical for virus recovery. Molecular-based identification techniques such as PCR could be used.

25 July 2007 in Aerobiologia
Verified
Journal Article
Closed access
PDF file
Seung Won KimSeung Won Kim
Seung Won Kim
MRM.A. Ramakrishnan
M.A. Ramakrishnan
PRPeter C. Raynor
Peter C. Raynor
SGSagar M. Goyal
Sagar M. Goyal

1 September 2011 in American Journal of Infection Control
Verified
Journal Article
Closed access
SGSagar Goyal
Sagar Goyal
SASenthilvelan Anantharaman
Senthilvelan Anantharaman
MRM.A. Ramakrishnan
M.A. Ramakrishnan
SSSuchitra Sajja
Suchitra Sajja
Seung Won KimSeung Won Kim
Seung Won Kim
PRPeter C. Raynor
Peter C. Raynor

7 March 2008 in Journal of Environmental Monitoring
Verified
Journal Article
Closed access
PDF file
NSNicholas J. Stanley
Nicholas J. Stanley
TKThomas H. Kuehn
Thomas H. Kuehn
Seung Won KimSeung Won Kim
Seung Won Kim
PRPeter C. Raynor
Peter C. Raynor
SASenthilvelan Anantharaman
Senthilvelan Anantharaman
SGSagar M. Goyal
Sagar M. Goyal
Background culturable bacteria aerosols were collected and identified in two large public buildings located in Minneapolis, Minnesota and Seattle, Washington over a period of 5 months and 3 months, respectively. The installed particulate air filters in the ventilation systems were used as the aerosol sampling devices at each location. Both pre and final filters were collected from four air handing units at each site to determine the influence of location within the building, time of year, geographical location and difference between indoor and outdoor air. Sections of each loaded filter were eluted with 10 ml of phosphate buffered saline (PBS). The resulting solutions were cultured on blood agar plates and incubated for 24 h at 36 °C. Various types of growth media were then used for subculturing, followed by categorization using a BioLog MicroStation (Biolog, Hayward, CA, USA) and manual observation. Environmental parameters were gathered near each filter by the embedded on-site environmental monitoring systems to determine the effect of temperature, humidity and air flow. Thirty nine different species of bacteria were identified, 17 found only in Minneapolis and 5 only in Seattle. The hardy spore-forming genus Bacillus was the most commonly identified and showed the highest concentrations. A significant decrease in the number of species and their concentration occurred in the Minneapolis air handling unit supplying 100% outdoor air in winter, however no significant correlations between bacteria concentration and environmental parameters were found.

21 July 2010 in Annals of Occupational Hygiene
Verified
Journal Article
Open access
PDF file
TLTaekhee Lee
Taekhee Lee
Seung Won KimSeung Won Kim
Seung Won Kim
WCWilliam P. Chisholm
William P. Chisholm
JSJames Slaven
James Slaven
MHMartin Harper
Martin Harper
The American Conference of Governmental Industrial hygienists (ACGIH) lowered the threshold limit value (TLV) for respirable crystalline silica (RCS) exposure from 0.05 to 0.025 mg m−3 in 2006. For a working environment with an airborne dust concentration near this lowered TLV, the sample collected with current standard respirable aerosol samplers might not provide enough RCS for quantitative analysis. Adopting high flow rate sampling devices for respirable dust containing silica may provide a sufficient amount of RCS to be above the limit of quantification even for samples collected for less than full shift. The performances of three high flow rate respirable samplers (CIP10-R, GK2.69, and FSP10) have been evaluated in this study. Eleven different sizes of monodisperse aerosols of ammonium fluorescein were generated with a vibrating orifice aerosol generator in a calm air chamber in order to determine the sampling efficiency of each sampler. Aluminum oxide particles generated by a fluidized bed aerosol generator were used to test (i) the uniformity of a modified calm air chamber, (ii) the effect of loading on the sampling efficiency, and (iii) the performance of dust collection compared to lower flow rate cyclones in common use in the USA (10-mm nylon and Higgins–Dewell cyclones). The coefficient of variation for eight simultaneous samples in the modified calm air chamber ranged from 1.9 to 6.1% for triplicate measures of three different aerosols. The 50% cutoff size (50dae) of the high flow rate samplers operated at the flow rates recommended by manufacturers were determined as 4.7, 4.1, and 4.8 μm for CIP10-R, GK2.69, and FSP10, respectively. The mass concentration ratio of the high flow rate samplers to the low flow rate cyclones decreased with decreasing mass median aerodynamic diameter (MMAD) and high flow rate samplers collected more dust than low flow rate samplers by a range of 2–11 times based on gravimetric analysis. Dust loading inside the high flow rate samplers does not appear to affect the particle separation in either FSP10 or GK2.69. The high flow rate samplers overestimated compared to the International Standards Organization/Comité Européen de Normalisation/ACGIH respirable convention [up to 40% at large MMAD (27.5 μm)] and could provide overestimated exposure data with the current flow rates. However, both cyclones appeared to be able to provide relatively unbiased assessments of RCS when their flow rates were adjusted.