Line confocal sensors provide non-contact, high-resolution, and high-efficiency measurement and can be integrated into optical measurement systems such as Photon for three-dimensional topography measurement of complex surfaces. However, installation-induced tilt-pose errors of the sensor can couple height information with lateral position, thereby reducing the accuracy of profile reconstruction. To address this issue, this paper proposes a calibration-block-based tilt-pose error identification and compensation method for line confocal sensors. Using the known geometric features of the calibration block, the proposed method establishes a mapping relationship between sensor tilt-pose errors and measured profile distortion. Sensitivity analysis is performed to identify the dominant error components, and the tilt-pose errors are estimated in a single identification process, enabling quantitative compensation of the measured point cloud. Experimental results show that, after calibration and compensation, the maximum Z-direction height difference in the overlapping profile region of the calibration block is reduced from 12.782 μm to 0.307 μm. The proposed method requires no complex external alignment devices and provides an effective approach for high-precision integrated applications of line confocal sensors.
To ensure the credibility of measurement data from the Track Geometry Detection System (TGDS) and to achieve its dynamic and accurate evaluation, this paper analyzes and assesses the sources of uncertainty in the measurement of track geometric irregularities by the track inspection system based on a calibration test bench in the laboratory. To address the issue that the track inspection system is prone to sporadic outliers under electromagnetic interference and vibration, while conventional statistical methods are sensitive to outliers and tend to overestimate the repeatability uncertainty, this paper introduces a robust statistical method based on median absolute deviation (MAD) to evaluate the uncertainty introduced by repeatability. This robust approach effectively suppresses the influence of outliers by using the median instead of the mean and absolute deviations instead of squared deviations, thereby yielding a more realistic and reliable estimate of repeatability. Taking track gauge measurement as an example for uncertainty evaluation, experimental results show that the expanded uncertainty U = 0.64 mm, which satisfies one-third of the tolerance requirement for track gauge measurement, verifying the feasibility of the proposed method. The quantitative results of uncertainty sources in this paper can be used as Type B input for uncertainty evaluation in field practical measurements, providing a reliable metrological basis for the uncertainty evaluation of track inspection systems. Meanwhile, the dynamic evaluation of track inspection systems is realized, filling the gap in their dynamic and reliable evaluation under complex interferences.
To address the challenges in freeform surface measurement, such as steep gradient variations and irregular distributions of normal directions, this paper proposes a large-range-sensing differential confocal freeform surface measurement method based on parallel multi-channel transverse segmented detection. In this method, a D-shaped aperture is employed to convert axial defocus detection into transverse off-axis detection, and the laser transverse differential confocal (LTDC) intensity response signals are obtained through parallel multi-channel transverse segmented detection of the light spot. By piecewise fitting the linear regions of the laser normalized transverse differential confocal (LNTDC) intensity response signals and splicing adjacent linear intervals, a large-range sensing equation is established. By optimizing the key sensing parameters, the proposed method ultimately enables large-range and high-resolution measurement of surface height variations on the measured freeform surface. Experiments show that the axial measurement resolution reaches 0.5 nm, and the linear sensing range extends to 13.667 µm, representing an 11.4-fold improvement over the traditional differential confocal method. Under the same measurement conditions, the measurement efficiency of same freeform surface is increased by 6.33 times. The proposed method overcomes the difficulty of simultaneously achieving a large linear sensing range, high resolution, and high measurement efficiency in conventional differential confocal methods, and provides a new approach for high-precision measurement of freeform surface topography.