Ziyun Ding

Dr. Ziyun Ding

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 January 2016 in Journal of Biomechanical Engineering
Verified
Journal Article
Open access
PDF file
ZDZiyun Ding
Ziyun Ding
DNDaniel Nolte
Daniel Nolte
CTChui Kit Tsang
Chui Kit Tsang
DCDaniel Cleather
Daniel Cleather
AKAngela Elizabeth Kedgley
Angela Elizabeth Kedgley
ABAnthony M.J. Bull
Anthony M.J. Bull
Segment-based musculoskeletal models allow the prediction of muscle, ligament, and joint forces without making assumptions regarding joint degrees-of-freedom (DOF). The dataset published for the “Grand Challenge Competition to Predict in vivo Knee Loads” provides directly measured tibiofemoral contact forces for activities of daily living (ADL). For the Sixth Grand Challenge Competition to Predict in vivo Knee Loads, blinded results for “smooth” and “bouncy” gait trials were predicted using a customized patient-specific musculoskeletal model. For an unblinded comparison, the following modifications were made to improve the predictions: further customizations, including modifications to the knee center of rotation; reductions to the maximum allowable muscle forces to represent known loss of strength in knee arthroplasty patients; and a kinematic constraint to the hip joint to address the sensitivity of the segment-based approach to motion tracking artifact. For validation, the improved model was applied to normal gait, squat, and sit-to-stand for three subjects. Comparisons of the predictions with measured contact forces showed that segment-based musculoskeletal models using patient-specific input data can estimate tibiofemoral contact forces with root mean square errors (RMSEs) of 0.48–0.65 times body weight (BW) for normal gait trials. Comparisons between measured and predicted tibiofemoral contact forces yielded an average coefficient of determination of 0.81 and RMSEs of 0.46–1.01 times BW for squatting and 0.70–0.99 times BW for sit-to-stand tasks. This is comparable to the best validations in the literature using alternative models.

1 October 2016 in Journal of Biomechanics
Verified
Journal Article
Open access
DNDaniel Nolte
Daniel Nolte
CTChui Kit Tsang
Chui Kit Tsang
KZKai Yu Zhang
Kai Yu Zhang
ZDZiyun Ding
Ziyun Ding
AKAngela Elizabeth Kedgley
Angela Elizabeth Kedgley
ABAnthony M.J. Bull
Anthony M.J. Bull
Accurate muscle geometry for musculoskeletal models is important to enable accurate subject-specific simulations. Commonly, linear scaling is used to obtain individualised muscle geometry. More advanced methods include non-linear scaling using segmented bone surfaces and manual or semi-automatic digitisation of muscle paths from medical images. In this study, a new scaling method combining non-linear scaling with reconstructions of bone surfaces using statistical shape modelling is presented. Statistical Shape Models (SSMs) of femur and tibia/fibula were used to reconstruct bone surfaces of nine subjects. Reference models were created by morphing manually digitised muscle paths to mean shapes of the SSMs using non-linear transformations and inter-subject variability was calculated. Subject-specific models of muscle attachment and via points were created from three reference models. The accuracy was evaluated by calculating the differences between the scaled and manually digitised models. The points defining the muscle paths showed large inter-subject variability at the thigh and shank - up to 26mm; this was found to limit the accuracy of all studied scaling methods. Errors for the subject-specific muscle point reconstructions of the thigh could be decreased by 9% to 20% by using the non-linear scaling compared to a typical linear scaling method. We conclude that the proposed non-linear scaling method is more accurate than linear scaling methods. Thus, when combined with the ability to reconstruct bone surfaces from incomplete or scattered geometry data using statistical shape models our proposed method is an alternative to linear scaling methods.

28 March 2019 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
ZDZiyun Ding
Ziyun Ding
CTChui K. Tsang
Chui K. Tsang
DNDaniel Nolte
Daniel Nolte
AKAngela E. Kedgley
Angela E. Kedgley
ABAnthony M.J. Bull
Anthony M.J. Bull
Objective: The accuracy of a musculoskeletal model relies heavily on the implementation of the underlying anatomical dataset. Linear scaling of a generic model, despite being time and cost efficient, produces substantial errors as it does not account for gender differences and inter-individual anatomical variations. The hypothesis of this study is that linear scaling to a musculoskeletal model with gender and anthropometric similarity to the individual subject produces similar results to the ones that can be obtained from a subject-specific model. Methods:A lower limb musculoskeletal anatomical atlas was developed consisting of ten datasets derived from magnetic resonance imaging of healthy subjects and an additional generic dataset from the literature. Predicted muscle activation and joint reaction force were compared with electromyography and literature data. Regressions based on gender and anthropometry were used to identify the use of atlas. Results: Primary predictors of differences for the joint reaction force predictions were mass difference for the ankle (p <; 0.001) and length difference for the knee and hip (p <; 0.017). Gender difference accounted for an additional 3% of the variance (p <; 0.039). Joint reaction force differences at the ankle, knee, and hip were reduced by between 50% and 67% (p = 0.005) when using a musculoskeletal model with the same gender and similar anthropometry in comparison with a generic model. Conclusion: Linear scaling with gender and anthropometric similarity can improve joint reaction force predictions in comparison with a scaled generic model. Significance: The presented scaling approach and atlas can improve the fidelity and utility of musculoskeletal models for subject-specific applications.

19 May 2020 in Journal of Orthopaedic Research
Verified
Journal Article
Open access
PDF file
ZDZiyun Ding
Ziyun Ding
HJHannah L. Jarvis
Hannah L. Jarvis
ABAlexander N. Bennett
Alexander N. Bennett
RBRichard Baker
Richard Baker
ABAnthony M.J. Bull
Anthony M.J. Bull
High functioning military transtibial amputees (TTAs) with well‐fitted state of the art prosthetics have gait that is indistinguishable from healthy individuals, yet they are more likely to develop knee osteoarthritis (OA) of their intact limbs. This contrasts with the information at the knees of the amputated limbs that have been shown to be at a significantly reduced risk of pain and OA. The hypothesis of this study is that biomechanics can explain the difference in knee OA risk. Eleven military unilateral TTAs and eleven matched healthy controls underwent gait analysis. Muscle forces and joint contact forces at the knee were quantified using musculoskeletal modeling, validated using electromyography measurements. Peak knee contact forces for the intact limbs on both the medial and lateral compartments were significantly greater than the healthy controls (P ≤ .006). Additionally, the intact limbs had greater peak semimembranosus (P = .001) and gastrocnemius (P ≤ .001) muscle forces compared to the controls. This study has for the first time provided robust evidence of increased force on the non‐affected knees of high functioning TTAs that supports the mechanically based hypothesis to explain the documented higher risk of knee OA in this patient group. The results suggest several protentional strategies to mitigate knee OA of the intact limbs, which may include the improvements of the prosthetic foot control, socket design, and strengthening of the amputated muscles.

24 January 2019 in Annals of Biomedical Engineering
Verified
Journal Article
Open access
PDF file
CKChristian Klemt
Christian Klemt
DNDaniel Nolte
Daniel Nolte
ZDZiyun Ding
Ziyun Ding
LRLance Rane
Lance Rane
RQRebecca A. Quest
Rebecca A. Quest
ABAnthony M.J. Bull
Anthony M.J. Bull
Linear scaling of generic shoulder models leads to substantial errors in model predictions. Customisation of shoulder modelling through magnetic resonance imaging (MRI) improves modelling outcomes, but model development is time and technology intensive. This study aims to validate 10 MRI-based shoulder models, identify the best combinations of anthropometric parameters for model scaling, and quantify the improvement in model predictions of glenohumeral loading through anthropometric scaling from this anatomical atlas. The shoulder anatomy was modelled using a validated musculoskeletal model (UKNSM). Ten subject-specific models were developed through manual digitisation of model parameters from high-resolution MRI. Kinematic data of 16 functional daily activities were collected using a 10-camera optical motion capture system. Subject-specific model predictions were validated with measured muscle activations. The MRI-based shoulder models show good agreement with measured muscle activations. A tenfold cross-validation using the validated personalised shoulder models demonstrates that linear scaling of anthropometric datasets with the most similar ratio of body height to shoulder width and from the same gender (p < 0.04) yields best modelling outcomes in glenohumeral loading. The improvement in model reliability is significant (p < 0.02) when compared to the linearly scaled-generic UKNSM. This study may facilitate the clinical application of musculoskeletal shoulder modelling to aid surgical decision-making.

7 March 2025 in IEEE Access
Verified
Journal Article
Open access
SRS. M. Atoar Rahman
S. M. Atoar Rahman
IKIbrahim Khalil
Ibrahim Khalil
HZHui Zhou
Hui Zhou
YGYu Guo
Yu Guo
ZDZiyun Ding
Ziyun Ding
ZDZhang Dingguo
Zhang Dingguo
Electroencephalography (EEG) can non-invasivey measure neuronal events and reflect brain activity at different locations on the scalp. Early studies for EEG signal processing have focused more on extracting EEG temporal features and considered the topology of EEG channels less due to the limitation of rich spatial information. Graph neural networks (GNNs), as a new kind of deep learning method, can use EEG signals as graph vertices, capturing the hidden topological connections between signals. GNNs have made great progress in EEG studies due to the advantage. In this overview, we review the very new and fundamental models of GNNs and their modifications, such as graph regularized neural networks, graph convolutional neural networks, spatial-temporal graph neural networks, graph attention networks, and their variants in EEG signal analysis fields. The applications of GNNs are summarized in the domains of emotion detection, epilepsy seizure detection, stroke rehabilitation, Alzheimer’s disease diagnosis, motor imagery detection, neurological disease diagnosis, major depressive disorder, and driving fatigue detection. We employed a Systematic Literature Review (SLR) approach to select 79 papers for a comprehensive review. The current state is analyzed and forecasts are provided based on the available difficulties. We conclude by suggesting potential directions for future research in this rapidly developing topic.