Narcis Gratian Crăciun

Mr. Narcis Gratian Crăciun


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 December 2024 in Robotics
Verified
Journal Article
Open access
PDF file
ETElida-Gabriela Tulcan
Elida-Gabriela Tulcan
CSCarmen Sticlaru
Carmen Sticlaru
AOAlexandru Oarcea
Alexandru Oarcea
MSMelania Olivia SANDU
Melania Olivia SANDU
NCNarcis Gratian Crăciun
Narcis Gratian Crăciun
ELErwin-Christian Lovasz
Erwin-Christian Lovasz
Current disinfection robots either have a bulky design or cannot operate in multiple configurations, therefore being unable to disinfect the hard-to-reach areas, which leads to low efficiency of the disinfection process. A solution for this problem would be to use disinfection robots with folding mechanisms which can operate in different configurations based on the area type that needs to be disinfected. This paper presents the feasibility study of the 7-PR(RRRR)RP seven-bar linkage used for a disinfection robot with folding mechanism. First, the structure’s parameters were computed with a synthesis method by developing the inequalities system in order to avoid the singularities positions of the mechanism. This initial method took into consideration different values of the design coefficient p (which indicates the two possible designs of the selected linkage) and an arbitrary value of the coefficient k > 1, which was imposed in order to substitute the resulting inequalities system with an equation system. However, applying this method does not ensure that the optimal 7-PR(RRRR)RP seven-bar linkage structure for the design of a medical disinfection robot is obtained. Furthermore, an optimized synthesis method was applied, which took into consideration the ratio between the total height of the mechanism and its total size. The parameters of the seven-bar linkage were computed for multiple values of the design coefficient p ∈ [1.1; 2] and multiple values of the coefficient k ∈ (0; 2], while a target function was implemented in order to identify the mechanism with the highest height range and the lowest size, which is considered to be the optimal structure for the design of a medical disinfection robot with a folding mechanism. The accuracy and the reliability of the results are furthermore strengthened by a performance analysis between the optimal indicated structure from the optimized synthesis method and other 7-PR(RRRR)RP seven-bar linkage structures, which were computed with different values of the parameters.

23 December 2024 in Machines
Verified
Journal Article
Open access
PDF file
NCNarcis Gratian Crăciun
Narcis Gratian Crăciun
ETElida-Gabriela Tulcan
Elida-Gabriela Tulcan
AOAlexandru Oarcea
Alexandru Oarcea
CCCristian Ciapa
Cristian Ciapa
ELErwin-Christian Lovasz
Erwin-Christian Lovasz
This article has as the main subject the exoskeleton devices used in rehabilitation applications of the wrist joint for patients who are in the recovery period after suffering a stroke. Exoskeleton devices have some advantages compared to classic therapies, such as the possibility of performing rehabilitation exercises from the comfort of your own home. Therefore, in this article, a short state of the art with the main devices developed at the present time was carried out. By developing a structural analysis, it was shown that the parallel manipulator structures used for the development of the exoskeleton have 2 DoF, and they can contain RRU, RTU, or TRU connection legs. Next, the kinematic analysis of the structure with RRU connection legs is presented, from which the transmission function for the four-bar linkages was extracted. The study continues with the optimization of the synthesis in order to achieve a higher value for the minimum input transmission angle and a lower value for the total size area. Using the optimized results, a 3D prototype and the performance analysis were developed. The main conclusion of this article is that the presented 2-RRU-U parallel manipulator can be a suitable proposal for a rehabilitation exoskeleton-type device due to the optimization of the total size area and the higher value of the minimum input transmission angle.

19 May 2023
Verified
Book Chapter
Closed access
PDF file
NCNarcis Gratian Crăciun
Narcis Gratian Crăciun
ELErwin-Christian Lovasz
Erwin-Christian Lovasz

27 September 2024
Verified
Book Chapter
Closed access
PDF file
NCNarcis Gratian Crăciun
Narcis Gratian Crăciun
ETElida-Gabriela Tulcan
Elida-Gabriela Tulcan
CCCristian Ciapa
Cristian Ciapa
ELErwin-Christian Lovasz
Erwin-Christian Lovasz


2 January 2025
Verified
Book Chapter
Closed access
PDF file
ETElida-Gabriela Tulcan
Elida-Gabriela Tulcan
CSCarmen Sticlaru
Carmen Sticlaru
NCNarcis Gratian Crăciun
Narcis Gratian Crăciun
FPFlorina Pop
Florina Pop
ELErwin-Christian Lovasz
Erwin-Christian Lovasz