Lukasz Szkolka

Dr. Lukasz Szkolka


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2024 in The Journal of Cardiovascular Surgery
Verified
Journal Article
Closed access
LSLukasz Szkolka
Lukasz Szkolka
DLDorota Lyko-Morawska
Dorota Lyko-Morawska
SBSimone Balocco
Simone Balocco
LBLukasz Bedkowski
Lukasz Bedkowski
MBMichal Buczek
Michal Buczek
WKWaclaw Kuczmik
Waclaw Kuczmik
Article: Vascular surgery study of the CGuard MicroNet-covered stent in patients with indication to carotid revascularization: POLGUARD - The Journal of Cardiovascular Surgery 2023 Nov 10 - Minerva Medica - Journals

16 December 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
DŁDorota Łyko-Morawska
Dorota Łyko-Morawska
LSLukasz Szkolka
Lukasz Szkolka
MSMichał Serafin
Michał Serafin
ESEmila Senderek
Emila Senderek
PKPaweł Kiczmer
Paweł Kiczmer
WKWaclaw Kuczmik
Waclaw Kuczmik
Background: The external carotid artery (ECA) supplies blood to various facial and neck regions and may contribute to collateral cerebral perfusion. With the rise in carotid artery stenting (CAS) as a treatment for carotid stenosis, ECA overstenting has become a common procedure feature. This study aimed to assess the incidence, characteristics, and duration of facial pain following CAS, hypothesizing that ECA overstenting may contribute to facial pain. Materials and Methods: This prospective study included 55 patients treated with CAS for internal carotid artery (ICA) stenosis at a single center. Patients’ facial pain was evaluated using a numeric rating scale (NRS) before, immediately after, and 24 h post-CAS. Patient data, including demographics, comorbidities, and procedural details, were analyzed to assess the relationship between ICA stenosis degree, ECA diameter changes, and facial pain incidence. Results: CAS was associated with intraoperative facial pain in 27.27% of patients, with 7.28% reporting residual pain 24 h post-procedure. Pain occurrence was significantly higher in patients with lower ICA stenosis (p = 0.04). The median ECA diameter decreased from 4.11 mm to 3.16 mm (p < 0.001) after CAS, with ECA overstenting observed in 96.4% of cases. No significant relationship was found between pain severity and stent width or length. Conclusions: This study highlights that CAS significantly decreases the diameter of ECA. Additionally, ECA overstenting might be associated with perioperative and postoperative facial pain, emphasizing the need for careful monitoring of ECA patency following CAS.