Ehsan Samiei

Dr. Ehsan Samiei

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 May 2016 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
ESEhsan Samiei
Ehsan Samiei
MTMaryam Tabrizian
Maryam Tabrizian
Mina HoorfarMina Hoorfar
Mina Hoorfar
This review evaluates the possibility of developing portable digital microfluidic platforms for lab-on-a-chip applications.

24 October 2018 in The Analyst
Verified
Journal Article
Closed access
PDF file
ADArash Dalili
Arash Dalili
ESEhsan Samiei
Ehsan Samiei
Mina HoorfarMina Hoorfar
Mina Hoorfar
We have reviewed the microfluidic approaches for cell/particle isolation and sorting, and extensively explained the mechanism behind each method.

Verified
Journal Article
Open access
PDF file
ESEhsan Samiei
Ehsan Samiei
ASAmir Seyfoori
Amir Seyfoori
BTBrian Toyota
Brian Toyota
Saeid GhavamiSaeid Ghavami
Saeid Ghavami
Mohsen AkbariMohsen Akbari
Mohsen Akbari
Glioblastoma multiforme (GBM) is a rapidly progressive and deadly form of brain tumor with a median survival rate of ~15 months. GBMs are hard to treat and significantly affect the patient’s physical and cognitive abilities and quality of life. Temozolomide (TMZ)—an alkylating agent that causes DNA damage—is the only chemotherapy choice for the treatment of GBM. However, TMZ also induces autophagy and causes tumor cell resistance and thus fails to improve the survival rate among patients. Here, we studied the drug-induced programmed cell death and invasion inhibition capacity of TMZ and a mevalonate cascade inhibitor, simvastatin (Simva), in a three-dimensional (3D) microfluidic model of GBM. We elucidate the role of autophagy in apoptotic cell death by comparing apoptosis in autophagy knockdown cells (Atg7 KD) against their scrambled counterparts. Our results show that the cells were significantly less sensitive to drugs in the 3D model as compared to monolayer culture systems. An immunofluorescence analysis confirmed that apoptosis is the mechanism of cell death in TMZ- and Simva-treated glioma cells. However, the induction of apoptosis in the 3D model is significantly lower than in monolayer cultures. We have also shown that autophagy inhibition (Atg7 KD) did not change TMZ and Simva-induced apoptosis in the 3D microfluidic model. Overall, for the first time in this study we have established the simultaneous detection of drug induced apoptosis and autophagy in a 3D microfluidic model of GBM. Our study presents a potential ex vivo platform for developing novel therapeutic strategies tailored toward disrupting key molecular pathways involved in programmed cell death and tumor invasion in glioblastoma.

1 January 2011 in European Journal of Mechanics - B/Fluids
Verified
Journal Article
Closed access
ESEhsan Samiei
Ehsan Samiei
MSMehrzad Shams
Mehrzad Shams
REReza Ebrahimi
Reza Ebrahimi

8 October 2018 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
ASAmir Seyfoori
Amir Seyfoori
ESEhsan Samiei
Ehsan Samiei
NJNeda Jalili
Neda Jalili
BGBrent Godau
Brent Godau
MRMehdi Rahmanian
Mehdi Rahmanian
Mohsen AkbariMohsen Akbari
Mohsen Akbari
Self-filling microwell arrays hold great promise for the production of 3D tumor spheroids and organoids for disease modeling and drug discovery.

10 January 2019 in Sensors
Verified
Journal Article
Open access
PDF file
GLGeorge Luka
George Luka
ESEhsan Samiei
Ehsan Samiei
SDSoroush Dehghani
Soroush Dehghani
TJThomas Johnson
Thomas Johnson
Homayoun NajjaranHomayoun Najjaran
Homayoun Najjaran
Mina HoorfarMina Hoorfar
Mina Hoorfar
Cryptosporidium, an intestinal protozoan pathogen, is one of the leading causes of diarrhea in healthy adults and death in children. Detection of Cryptosporidium oocysts has become a high priority to prevent potential outbreaks. In this paper, a label-free interdigitated-based capacitive biosensor has been introduced for the detection of Cryptosporidium oocysts in water samples. Specific anti-Cryptosporidium monoclonal antibodies (IgG3) were covalently immobilized onto interdigitated gold electrodes as the capture probes, and bovine serum albumin was used to avoid non-specific adsorption. The immobilization of the antibodies was confirmed by measuring the change in the contact angle. The detection was achieved by measuring the relative change in the capacitive/dielectric properties due to the formation of Cryptosporidium-antibody complex. The biosensor has been tested for different concentrations of Cryptosporidium. The results show that the biosensor developed can accurately distinguish different numbers of captured cells and densities on the surface of the biosensor. The number of Cryptosporidium oocysts captured on the electrode surface was confirmed using a fluorescein isothiocyanate (FITC) immunofluorescence assay. The response from the developed biosensor has been mainly dependent on the concentration of Cryptosporidium under optimized conditions. The biosensor showed a linear detection range between 15 and 153 cells/mm2 and a detection limit of 40 cells/mm2. The label-free capacitive biosensor developed has a great potential for detecting Cryptosporidium in environmental water samples. Furthermore, under optimized conditions, this label-free biosensor can be extended for detection of other biomarkers for biomedical and environmental analyses.