Kang Mu

Dr. Kang Mu

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 January 2025 in Atmosphere
Verified
Journal Article
Open access
PDF file
KMKang Mu
Kang Mu
QSQiong Suo
Qiong Suo
FDFangliang Ding
Fangliang Ding
CJChangwei Jiang
Changwei Jiang
XZXiaofeng Zhang
Xiaofeng Zhang
JYJing Ye
Jing Ye
In recent years, the surge in air-conditioning ownership and usage has led to significant heat rejection, impacting the surrounding atmosphere. Despite this, studies examining the spatiotemporal effects of air-conditioning heat rejection at a block scale remain limited. Additionally, comparative studies on the role of building areas with air-conditioning systems versus natural underlying surfaces in the urban thermal environment are relatively scarce. This study employs field measurements and ArcGIS technology to investigate the local thermal and humidity environments, as well as the spatiotemporal distribution of heat rejection from air-conditioning systems in Wuyi Square, Changsha. Results show that cooling tower exhausts in commercial buildings maintain relative humidity levels of 95.2% to 99.8% during the day, enhancing surrounding humidity. At night, the humidity aligns with atmospheric levels (from 50.3% to 62.5%). The cooling tower exhaust temperature is approximately 2.2 °C lower during the day and 2.4 °C higher at night compared to the surrounding temperatures. In contrast, exhausts from split-type air-conditioning units in residential buildings have an average relative humidity about 14.2% lower than the atmosphere humidity, with temperature averages being 5.2 °C higher during the day and 6.5 °C higher at night, raising surrounding temperatures. The study also finds that natural surface areas are up to 3.1 °C cooler and 9.6% more humid compared to built environment surfaces. Furthermore, residential areas have air temperatures about 0.3 °C higher than commercial zones, with a humidity distribution approximately 0.5% lower. These findings offer a theoretical foundation for enhancing urban thermal environments and informing urban planning and design.

4 February 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
KMKang Mu
Kang Mu
ZLZhaolong Li
Zhaolong Li
WLWei Li
Wei Li
XSXiaoqin Sun
Xiaoqin Sun
JYJing Ye
Jing Ye
QCQilin Cao
Qilin Cao
To investigate the impact of split air conditioner (AC) heat rejection on thermal environment in the residential areas, this study takes the Lifa New City residential community in Changsha as a case study. The effects on the local microclimate were analyzed through a combination of field measurements and CFD numerical simulations. Field measurements data show that the average air temperature in the split AC exhaust zones is approximately 5 °C higher than in non-exhaust areas, with the maximum temperature difference reaching 8 °C at night, highlighting a greater nocturnal impact. In terms of relative humidity, the split AC exhaust zones are slightly lower than the atmospheric background, with the influence confined to localized areas. CFD simulations results indicate that increased split AC usage rate significantly deteriorating local thermal environment. Numerical simulations were conducted under 50%, 75%, and 100% split AC usage rate respectively, with the 100% usage rate representing the worst-case condition. When usage rate increases from 50% to 100%, the average air temperature rises by 0.7 °C during the day and 0.9 °C at night, and the temperature increased gradient approximately has reached 0.72 °C is observed near exhaust outlets, indicating a very significant heat accumulation phenomenon. And the wind speed field distribution is influenced by the coupling of split AC heat exhaust and residential building layout. Maximum wind speeds increase from 3.22 m/s to 4.43 m/s during the day and from 3.75 m/s to 4.91 m/s at night, and a low wind speed zone forms in the downstream area. The thermal regulation capacity of underlying surfaces varies significantly. Impervious concrete surfaces show temperature increases of 1.7 °C by day and 0.9 °C by night due to limited evaporative cooling and high solar absorption. In contrast, due to the high heat capacity and evaporative cooling effect, the air temperature around water bodies and greenbelts increased slightly by 0.08°C during the daytime and decreased by 0.28°C at nighttime, exhibit the superior thermal buffering performance.

22 May 2026 in Buildings
Verified
Journal Article
Open access
PDF file
QLQian Liu
Qian Liu
WLWei Li
Wei Li
JLJunhong Li
Junhong Li
KMKang Mu
Kang Mu
XSXiaoqin Sun
Xiaoqin Sun
JZJili Zhang
Jili Zhang
Existing thermal sensation prediction models typically examine the relationship between skin temperature and thermal sensation during cooling or heating seasons. However, due to significant fluctuations in indoor thermal environments during shoulder seasons and considerable individual variation in clothing preferences, traditional thermal sensation prediction models demonstrate poor predictive performance during shoulder seasons. This study aims to investigate the relationship between facial skin temperature and clothing insulation versus thermal sensation under shoulder seasonal conditions and to establish a predictive model for human thermal sensation influenced by clothing insulation. First, facial temperature data under different clothing conditions are collected online using infrared thermal imaging equipment. Subjective thermal sensations are obtained through questionnaires, enabling analysis of the influence of relationships among clothing insulation, facial temperature, and thermal sensation. Subsequently, correlation analysis is used to identify the facial temperature zones closely related to human thermal sensation. Finally, a random forest algorithm is employed to establish a thermal sensation prediction model. Research findings indicate that during shoulder seasons, the left and right cheeks and lips exhibit a higher correlation with thermal sensation. Due to variations in clothing insulation, thermal sensation models based solely on facial temperature characteristics demonstrate lower predictive accuracy and struggle to overcome interference caused by individual clothing differences. After incorporating clothing insulation as a key input feature parameter, the model’s Root Mean Square Error decreased from 0.869 to 0.533, representing a 38.7% improvement in prediction accuracy. This demonstrates that the clothing insulation parameter plays a crucial role in enhancing the precision of human thermal sensation prediction models during shoulder seasons.