Adan William de Melo Navarro

Dr. Adan William de Melo Navarro


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 March 2024 in Veterinary Sciences
Verified
Journal Article
Open access
PDF file
RVRebeca Costa Vitor
Rebeca Costa Vitor
JOJoana Thaisa Santos Oliveira
Joana Thaisa Santos Oliveira
ANAdan William de Melo Navarro
Adan William de Melo Navarro
ALAna Carolina Ribeiro Lima
Ana Carolina Ribeiro Lima
GOGabriela Mota Sena de Oliveira
Gabriela Mota Sena de Oliveira
RCRenata Santiago Alberto Carlos
Renata Santiago Alberto Carlos
Background: Feline obesity is the most common nutritional disease in cats. This study aimed to investigate the differences between systolic blood pressure (SBP) and circulating concentrations of glucose, fructosamine, and serum amyloid-A (SAA) in ideal-weight, overweight, and obese cats. Methods: The animals were divided into three groups: ideal-weight (BCS 5, N = 20), overweight (BCS 6, N = 20), and obese cats (BCS ≥ 7, N = 20). SBP, circulating concentrations of glucose, fructosamine, and SAA were evaluated. Results: The SBP values of the ideal-weight, overweight, and obese cats were 140.0 mmHg, 160.0 mmHg, and 160.0 mmHg, respectively. The blood glucose and fructosamine levels for the ideal, overweight, and obese cats were 104.0 mg/dL and 245.0 µmol/L, 123.0 mg/dL and 289.0 µmol/L, and 133.0 mg/dL and 275.0 µmol/L, respectively, for each group. The SAA values were <5 ug/mL in all the groups. The SBP values of the cats with ideal BCS were significantly lower compared to overweight (p = 0.019) and obese (p = 0.001) cats. The blood glucose values of obese cats were higher than those of ideal-weight cats (p = 0.029). There was no statistical difference between the groups for fructosamine and SAA. Conclusions: Obese cats had significantly higher SBP and blood glucose concentrations than ideal-weight cats, showing the effect of BSC on these parameters.

2 February 2025 in Veterinary Sciences
Verified
Journal Article
Open access
PDF file
MMMatheus Matioli Mantovani
Matheus Matioli Mantovani
ACAny C. A. Costa
Any C. A. Costa
MLMayara Travalini de Lima
Mayara Travalini de Lima
LSLuis Felipe Neves dos Santos
Luis Felipe Neves dos Santos
KSKimberly Félix Silva
Kimberly Félix Silva
DFDenise Tabacchi Fantoni
Denise Tabacchi Fantoni
Blood pressure (BP) monitoring is essential during anesthesia to maintain cardiovascular stability and detect hypotension. This study evaluated the agreement and diagnostic accuracy of linear deflection oscillometry (LDO) and Doppler compared to invasive blood pressure (IBP) in anesthetized dogs. Eleven healthy dogs were anesthetized, and BP measurements were taken using LDO, Doppler, and IBP methods under normotensive and hypotensive conditions. The LDO device demonstrated superior agreement, assessed using Bland–Altman analysis, with IBP, especially in hypotensive conditions, compared to the Doppler method. LDO showed bias and standard deviation in the hypotensive state, with a mean and systolic arterial pressure (MAP and SAP) of −5.1 ± 7.9 and −5.6 ± 12.5 mmHg, respectively. Conversely, Doppler measurements tended to overestimate SAP during hypotension, presenting a bias of −13 ± 15.45 mmHg. The LDO achieved an area under the curve (AUC) of 0.809 for hypotension detection, with an MAP cutoff of ≤72 mmHg (sensitivity: 90%, specificity: 63%). Meanwhile, the best threshold for Doppler measurements was an AUC of 0.798, SAP ≤ 100 mmHg (sensitivity: 77.8%, specificity: 81.8%). These results indicate that LDO is a reliable method for hypotension detection in anesthetized dogs, with potential applications for real-time monitoring. In contrast, the Doppler method may help confirm hypotension diagnoses.