In this work, we employed a convenient one-step synthesis method for synthesizing Cu2ZnSnSe4 (CZTSe) nanocrystals (NCs) in an excess selenium environment. This excess selenium situation enhanced the reaction of metal acetylacetonates with selenium, resulting in the burst nucleation of NCs at relatively low temperatures. The phase morphology and surface and optoelectronic properties of NCs before and after ligand exchange were discussed in depth. It was found that pure tetragonal-phase structure CZTSe NCs with approximately 1.7-eV bandgap could be synthesized. The removal of large organic molecules on CZTSe NCs after ligand exchange by S2− decreased the resistivity. The bandgap of the films after ligand exchange by 550°C selenization was also decreased due to better crystallinity. For potential application in CZTSe solar cells, we constructed an energy level diagram to explain the mutual effect between the absorption layer and CdS layer. Using cyclic voltammetry (CV) measurement, we found that the highest occupied molecular orbital (HOMO) and lowest unoccupied molecular orbital (LUMO) energy levels of CZTSe films shifted down after ligand exchange. After energy level alignment at the CdS/CZTSe interface, a type I band alignment structure was more conveniently formed after ligand exchange. This structure acted as the barrier against injection electrons from ZnO to the CZTSe layer, and recombination would subsequently be depressed.
31 August 2017 in IOP Conference Series: Earth and Environmental Science
High quality and continuous in situ silicate data are required to investigate the mechanism of the biogeochemical cycles and the formation of red tide. There is an urgently growing need for autonomous in situ silicate instruments that perform determination on various platforms. However, due to the high reagents and power consumption, as well as high system complexity leading to low reliability and robustness, the performance of the commercially available silicate sensors is not satisfactory. With these problems, here we present a new generation of microfluidic continuous flow analysis silicate sensor with sufficient analytical performance and robustness, for in situ determination of soluble silicate in seawater. The reaction mechanism of this sensor is based on the reaction of silicate with ammonium molybdate to form a yellow silicomolybdate complex and further reduction to silicomoIybdenum blue by ascorbic acid. The minimum limit of detection was 45.1 nmol L-1, and the linear determination range of the sensor is 0-400 μmol L-1. The recovery rate of the actual water is between 98.1%-104.0%, and the analyzing cycle of the sensor is about 5 minutes. This sensor has the advantages of high accuracy, high integration, low water consumption, and strong anti-interference ability. It has been successfully applied to measuring the silicate in seawater in Jiaozhou Bay.
Dissolved organic carbon refers to soluble carbon substances in water bodies and can be used as an important indicator for water pollution. Spectroscopic detection is commonly used to detect dissolved organic carbon in seawater. However, independent spectral methods are susceptible to interference, and insufficient extraction of the data features can occur. Accordingly, this study introduces a multisource spectral fusion method that relies on a combination of principal component analysis and convolutional neural networks to construct the detection model. The Bayesian correction method is used for calibration, and the dissolved organic carbon content of 10 groups of unfiltered seawater samples is analyzed. Correcting the spectral data acquired from samples containing impurities significantly improved the linear correlation coefficient R2 of dissolved organic carbon from 0.8891 to 0.9838. Similarly, the mean absolute error was significantly reduced from 15.33% to 3.24%, while the individual absolute error was effectively controlled, remaining within 9%. The obtained results show that the developed method effectively integrates the ultraviolet absorption and fluorescence spectral data and overcomes interference from other substances using the Bayesian correction method. Overall, this provides a highly accurate detection system with potential applications in monitoring the marine environment.
Dissolved organic carbon refers to soluble carbon substances in water bodies, and can be used as an important indicator for water pollution. Spectroscopic detection is commonly used to detect dissolved organic carbon in seawater. However, independent spectral methods are susceptible to interference, and insufficient extraction of the data features can occur. Accordingly, this study introduces a multi-source spectral fusion method that relies on a combination of principal component analysis and convolutional neural networks to construct the detection model. The Bayesian correction method is used for calibration, and the dissolved organic carbon contents of 10 groups of unfiltered seawater samples is analyzed. Correcting the spectral data acquired from samples containing impurities significantly improved the linear correlation coefficient R² of dissolved organic carbon from 0.8891 to 0.9838. Similarly, the mean absolute error is significantly reduced from 15.33% to 3.24%, while the individual absolute error is effectively controlled, remaining within 9%. The obtained results show that the developed method effectively integrates the ultraviolet absorption and fluorescence spectral data, and overcomes interference from other substances using the Bayesian correction method. Overall, this provides a highly accurate detection system with potential applications in monitoring the marine environment.