Ibrahim feyyaz Naldemir

Dr. Ibrahim feyyaz Naldemir


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 September 2022 in Psychiatry Research: Neuroimaging
Verified
Journal Article
Closed access
ESEnes Sarigedik
Enes Sarigedik
INIbrahim feyyaz Naldemir
Ibrahim feyyaz Naldemir
AKAhmet Kursat Karaman
Ahmet Kursat Karaman
HAHasan Baki Altinsoy
Hasan Baki Altinsoy

1 March 2018 in The American Journal of Emergency Medicine
Verified
Journal Article
Closed access
INIbrahim feyyaz Naldemir
Ibrahim feyyaz Naldemir
DGDerya Guclu
Derya Guclu
HAH. Baki Altınsoy
H. Baki Altınsoy
HCH. Berk Canga
H. Berk Canga
OOOmer Onbas
Omer Onbas

28 September 2020 in Journal of Medical Case Reports
Verified
Journal Article
Open access
PDF file
INIbrahim feyyaz Naldemir
Ibrahim feyyaz Naldemir
EUElif Nisa Unlu
Elif Nisa Unlu
OOOmer Onbas
Omer Onbas
Background: Arterial tortuosity is a widespread condition commonly occurring in cerebral arteries and often associated with the elderly. Moderate arterial tortuosity is often not symptomatic, but if there is severe tortuosity, various symptoms may occur, depending on the localization. In the literature, many factors have been reported as causing tortuosity in the vertebral arteries. In this case report, considering the age of our patient, we propose that, in addition to these previously reported reasons, congenital factors may also contribute to this situation.Case presentation: We present a case of a 19-year-old Turkish patient with a tortuous vertebral artery causing pain and tingling in the right shoulder and neck. Magnetic resonance imaging revealed vertebral foramen enlargement thought to be secondary to a loop formation in the vertebral artery. The diagnosis was confirmed by magnetic resonance angiography.Conclusions: There are many causes of cervical radiculopathy. Arterial tortuosity, a rare cause of radiculopathy, should be considered as a differential diagnosis. Consideration of the existence of this variation is of great importance in preventing possible dangerous complications during surgery.

24 May 2023 in Angiology
Verified
Journal Article
Closed access
INIbrahim feyyaz Naldemir
Ibrahim feyyaz Naldemir
AKAhmet Kursat Karaman
Ahmet Kursat Karaman
DGDerya Güçlü
Derya Güçlü
EAEsra Koç Ay
Esra Koç Ay
OKOsman Kayapinar
Osman Kayapinar
HAHasan Baki Altınsoy
Hasan Baki Altınsoy
The present study investigated the relationship between pre-procedural radial intima-media thickness (rIMT) and radial artery thrombosis (RAO) in patients undergoing angiography using a transradial approach (TRA). Patients (n = 90) who underwent cerebral or peripheral arterial angiography using TRA were included in the study. Ultrasonographic evaluation was performed before and 12 h after the procedure. Preoperative rIMT measurement was performed at the distal radial artery. Presence of radial artery occlusion was evaluated by ultrasonography after radial catheterization and revealed occlusive thrombus in the radial artery in 13 patients. rIMT was found to be statistically significantly higher in patients with thrombus ( P < .05). When it was evaluated whether there was a correlation between age and rIMT, a positive significant correlation was found ( P < .01). Our study suggests that increase of rIMT may be a risk factor for RAO in the intervention area. Before the procedure, ultrasound (US) assessment of the radial artery may be useful in determining the risk of occlusion. Thus, RAO-related technical risk factors (procedure time, number of punctures, sheath thickness, etc.) can be managed more carefully in patients having radial angiography.

3 November 2024 in Acta Radiologica
Verified
Journal Article
Closed access
INIbrahim feyyaz Naldemir
Ibrahim feyyaz Naldemir
AKAhmet Kursat Karaman
Ahmet Kursat Karaman
HOHayri OĞUL
Hayri OĞUL
OOOmer Onbas
Omer Onbas
Background: Flow-related signal void artifacts can be visualized on the T2-weighted (T2W) three-dimensional sampling perfection with application-optimized contrast (3D-SPACE) sequence. Flow void artifacts in the cerebral aqueduct and the fourth ventricle can provide information about cerebrospinal fluid (CSF) flow dynamics. Purpose: In this study, we aimed to test the performance of the T2W 3D-SPACE sequence in assessing the CSF flow in the aqueduct and/or fourth ventricle. Material and Methods: A total of 137 patients (age range = 3–89 years) who underwent CSF flow study were included. The amount of signal loss on T2W 3D-SPACE due to flow in the aqueduct and fourth ventricle was assessed and graded using a 4-point scale of 0 (absence of flow void) to 3 (signal void filling the aqueduct and entire fourth ventricle). A correlation was then sought between the quantitative values obtained by phase-contrast magnetic resonance imaging (PC-MRI) and the amount of signal void in the 3D-SPACE sequence. Results: At the aqueduct level, there was a statistically significant difference in the forward flow velocity and the flow volume among different grades (all P < 0.001). In the grade 3 group, CSF peak systolic flow velocity and mean flow volume were found to be significantly higher than in the other grades ( P < 0.001). The mean aqueduct area in the grade 0 group was found to be significantly different from that in the other classes ( P < 0.001). Conclusion: The amount of signal loss in the fourth ventricle observed on T2W 3D-SPACE is correlated with the peak systolic velocity and flow volume measured quantitatively in PC-MRI.