Christian Ziemann

Dr. Christian Ziemann

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 April 2018 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
CZChristian Ziemann
Christian Ziemann
MSMaik Stille
Maik Stille
FCFlorian Cremers
Florian Cremers
TBThorsten M. Buzug
Thorsten M. Buzug
DRDirk Rades
Dirk Rades
Background: Metal artifacts caused by high‐density implants lead to incorrectly reconstructed Hounsfield units in computed tomography images. This can result in a loss of accuracy in dose calculation in radiation therapy. This study investigates the potential of the metal artifact reduction algorithms, Augmented Likelihood Image Reconstruction and linear interpolation, in improving dose calculation in the presence of metal artifacts.Materials and Methods: In order to simulate a pelvis with a double‐sided total endoprosthesis, a polymethylmethacrylate phantom was equipped with two steel bars. Artifacts were reduced by applying the Augmented Likelihood Image Reconstruction, a linear interpolation, and a manual correction approach. Using the treatment planning system Eclipse™, identical planning target volumes for an idealized prostate as well as structures for bladder and rectum were defined in corrected and noncorrected images. Volumetric modulated arc therapy plans have been created with double arc rotations with and without avoidance sectors that mask out the prosthesis. The irradiation plans were analyzed for variations in the dose distribution and their homogeneity. Dosimetric measurements were performed using isocentric positioned ionization chambers.Results: Irradiation plans based on images containing artifacts lead to a dose error in the isocenter of up to 8.4%. Corrections with the Augmented Likelihood Image Reconstruction reduce this dose error to 2.7%, corrections with linear interpolation to 3.2%, and manual artifact correction to 4.1%. When applying artifact correction, the dose homogeneity was slightly improved for all investigated methods. Furthermore, the calculated mean doses are higher for rectum and bladder if avoidance sectors are applied.Conclusion: Streaking artifacts cause an imprecise dose calculation within irradiation plans. Using a metal artifact correction algorithm, the planning accuracy can be significantly improved. Best results were accomplished using the Augmented Likelihood Image Reconstruction algorithm.

5 December 2016 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
CZChristian Ziemann
Christian Ziemann
MSMaik Stille
Maik Stille
FCFlorian Cremers
Florian Cremers
DRDirk Rades
Dirk Rades
TBThorsten M. Buzug
Thorsten M. Buzug
The quality of CT slices can be drastically reduced in the presence of high‐density objects such as metal implants within the patients’ body due to the occurrence of streaking artifacts. Consequently, a delineation of anatomical structures might not be possible, which strongly influences clinical examination. The aim of the study is to clinically evaluate the retrieval of attenuation values and structures by the recently proposed Augmented Likelihood Image Reconstruction (ALIR) and linear interpolation in the presence of metal artifacts. A commercially available phantom was equipped with two steel inserts. At a position between the metal rods, which shows severe streaking artifacts, different human tissue‐equivalent inserts are alternately mounted. Using a single‐source computer tomograph, raw data with and without metal rods are acquired for each insert. Images are reconstructed using the ALIR algorithm and a filtered back projection with and without linear interpolation. Mean and standard deviation are compared for a region of interest in the ALIR reconstructions, linear interpolation results, uncorrected images with metal rods, and the images without metal rods, which are used as a reference. Furthermore, the reconstructed shape of the inserts is analyzed by comparing different profiles of the image. The measured mean and standard deviation values show that for all tissue classes, the metal artifacts could be reduced using the ALIR algorithm and the linear interpolation. Furthermore, the HU values for the different classes could be retrieved with errors below the standard deviation in the reference image. An evaluation of the shape of the inserts shows that the reconstructed object fits the shape of the insert accurately after metal artifact correction. Moreover, the evaluation shows a drop in the standard deviation for the ALIR reconstructed images compared to the reference images while reducing artifacts and keeping the shape of the inserts, which indicates a noise reduction ability of the ALIR algorithm. HU values, which are distorted by metal artifacts, can be retrieved accurately with the ALIR algorithm and the linear interpolation approach. After metal artifact correction, structures, which are not perceptible in the original images due to streaking artifacts, are reconstructed correctly within the image using the ALIR algorithm. Furthermore, the ALIR produced images with a reduced noise level compared to reference images and artifact images. Linear interpolation results in a distortion of the investigated shapes and features remaining streaking artifacts.

20 February 2025 in Clinics and Practice
Verified
Journal Article
Open access
PDF file
Dirk RadesDirk Rades
Dirk Rades
JKJan-Dirk Küter
Jan-Dirk Küter
MSMichael von Staden
Michael von Staden
AAAhmed Al-Salool
Ahmed Al-Salool
CZChristian Ziemann
Christian Ziemann
FCFlorian Cremers
Florian Cremers
Background/Objectives: During radiotherapy for prostate cancer, the risk of radiation cystitis is increased if the volume of the bladder is small. According to previous studies, it is important that bladder volumes are ≥200 mL. Drinking protocols may be helpful in this context. Adherence to such protocols can be challenging, and may be improved by an app reminding patients before each session of radiotherapy to drink a certain amount of water. Our prospective phase 2 trial (REFILL-PAC-HYPO, NCT06784115) evaluates the impact of a reminder app on bladder filling in prostate cancer patients treated with hypo-fractionated radiotherapy. Methods: Twenty-seven patients need to be recruited for the REFILL-PAC-HYPO trial. Radiotherapy, preferably with volumetric-modulated arc therapy, uses hypo-fractionation with 20 × 3.0 Gy over four weeks. An app reminds patients to drink water (300 mL) 45 min before each session of hypo-fractionated irradiation. On the last day of their treatment, patients are asked about their satisfaction with the app. In the case of a dissatisfaction rate of >20%, the app requires modifications. If this rate is >40%, the app is considered not useful. Additionally, patients are asked about the impact of their participation in the trial and using the app on their general attitude towards health technology. Furthermore, the phase 2 cohort is compared to a historical control group treated with hypo-fractionated radiotherapy during recent years but not supported by an app. The REFILL-PAC-HYPO trial will contribute to identifying the potential value of a reminder app for bladder filling during hypo-fractionated radiotherapy for prostate cancer.

5 December 2024 in Cancers
Verified
Journal Article
Open access
PDF file
RZRouzbeh Zohri
Rouzbeh Zohri
LHLorenz Hahn
Lorenz Hahn
NSNiloufar Seyedi
Niloufar Seyedi
CPCordula Petersen
Cordula Petersen
CZChristian Ziemann
Christian Ziemann
ALAnastassia Löser
Anastassia Löser
Background/Objectives: This analysis aims to evaluate gender-specific differences in nutritional status, body weight changes, and their impact on overall survival (OS) in head and neck cancer (HNC) patients undergoing (chemo)radiotherapy (CRT). Methods: Between 2018 and 2020, 61 HNC (17 female and 44 male) patients were prospectively recruited to receive curative (chemo)radiotherapy. Nutritional assessments included dietary questionnaire screenings and records, anthropometric methods (body mass index, BMI, body composition via bioelectrical impedance analysis (BIA)), and the determination of biomarkers like albumin and CRP. Assessments were conducted before, during, and after (chemo)radiotherapy. Results: Gender differences were observed at baseline in Karnofsky performance status (p = 0.01), daily calorie intake (p = 0.04), phase angle (PA) (p = 0.003), and fat-free mass index (FFMI) (p < 0.001). During CRT, males showed a larger increase in calorie deficit (p < 0.001) and greater reductions in BMI, FFMI, and PA compared to females. Malnutrition risk (MUST score) increased significantly in males (p = 0.008) but not in females. Albumin and total protein declined in both genders, with a more pronounced drop in albumin for females. Survival analysis revealed that, for males, several factors, including baseline calorie deficit, BMI, PA, and FFMI, were linked to survival. For females, only albumin at therapy end was significantly associated with survival (p < 0.001). In multivariable analysis, baseline PA remained a significant predictor of survival for males (p = 0.026). Conclusions: Our findings suggest distinct gender differences in the nutritional and biochemical responses of HNC patients undergoing CRT, indicating the importance of tailored, gender-specific nutritional support during treatment.

3 October 2023 in Medical Dosimetry
Verified
Journal Article
Open access
CZChristian Ziemann
Christian Ziemann
FCFlorian Cremers
Florian Cremers
LMLaura Motisi
Laura Motisi
DADirk Albers
Dirk Albers
MMMiller MacPherson
Miller MacPherson
DRDirk Rades
Dirk Rades
This study presents a new treatment planning approach merging 3D-CRT and VMAT fields into a hybrid treatment plan (HybTP), in order to achieve an optimum dose coverage of the planning target volume (PTV) and protection of OAR. Craniospinal axis irradiation (CSI) treated with 3D conformal radiotherapy (3D-CRT) is associated with high doses to the heart and eye lenses but provides better sparing of lungs and kidneys compared to volumetric modulated arc therapy (VMAT). VMAT treatment spares eye lenses and the heart, but lungs and kidneys are not as effective as 3D-CRT. Thus, a combination of both techniques (HybTP) may be optimal in sparing all these organs at risk (OAR). The results of HybTP are compared with helical tomotherapy (HT), intensity modulated radio therapy (IMRT), VMAT, and 3D-CRT plans. Hybrid, HT, VMAT, IMRT, and 3D-CRT treatment plans for a male child (age 6 years) with medulloblastoma were created and compared. A total dose of 35.2 Gy (PTV) with a dose per fraction of 1.6 Gy was prescribed. The following dose acceptance criteria were defined: The plans were compared regarding dose homogeneity index (HI) and conformity index (CI), PTV coverage, (particularly at cribriform plate) and doses at OARs. Best conformity was achieved with HT (CI = 0.98) followed by VMAT (CI = 0.96), IMRT (CI = 0.91), HybTP (CI = 0.86), and 3D-CRT (CI = 0.83). The homogeneity index varied marginally. For both HT and IMRT the HI was 0.07, and for 3D-CRT, VMAT and HybTP the HI was between 0.13 and 0.15. The cribriform plate was sufficiently covered by HybTP, VMAT, and 3D-CRT. The dose acceptance criteria for OARs were met by HT and HybTP. VMAT did not meet the criteria for lung (Dmean = right 10.4 Gy/left 10.2 Gy), 3D-CRT did not meet the criteria for eye lenses (Dmax = right 32.3 Gy/left 33.1), and heart (V25≈44%) and IMRT did not meet the criteria for lung (Dmean = right 11.1 Gy/left 11.2 Gy) and eye lenses (Dmax = right 12.2 Gy/left 13.1). HybTP meets all defined acceptance criteria and has proved to be a reasonable alternative for CSI. With HybTP that combines VMAT at the brain and heart with 3D-CRT posterior spinal fields (to spare lungs and kidneys), both appropriate coverage of the PTV and sparing of OAR can be achieved.

26 February 2025 in In Vivo
Verified
Journal Article
Open access
PDF file
CZChristian Ziemann
Christian Ziemann
FCFlorian Cremers
Florian Cremers
MMMILLER MacPHERSON
MILLER MacPHERSON
DRDirk Rades
Dirk Rades
ALAnastassia Löser
Anastassia Löser
Background/Aim: Hippocampal-sparing whole-brain radiotherapy (HS-WBRT) is increasingly used for multiple brain metastases. However, most studies have not reported dose conformity indices (CI). In the only study indicating the CI, conformity was low (CI=0.7). We developed a new technique to achieve a significantly higher CI and better dose coverage. Patients and Methods: Ten patients received 30 Gy of HS-WBRT for brain metastases. Three variants of treatment plans (VAR1, VAR2, VAR3) were investigated. Volumetric modulated arc therapy plans with two (2ROT) or three rotations (3ROT) were created for each variant. Plans were compared for compliance with hippocampal sparing criteria, CI (where a higher value indicates better conformity), and homogeneity index (HI, where a lower value indicates better homogeneity). Results: Best results (highest CI, lowest HI) were achieved with the VAR3-3ROT technique (a new method), which yielded a CI=0.92-0.95 and a HI=0.05-0.09. VAR3-2ROT led to a CI=0.90-0.95 and a HI=0.06-0.11. With the other techniques, CI and HI ranged between 0.77-0.87 and 0.15-0.32, respectively. Conclusion: Our new technique achieved both appropriate hippocampal sparing and very high dose conformity of ≥0.9. Significant underdosage outside the hippocampal-sparing area was avoided.