Background: The technical quality of root canal treatment (RCT) may impact on the outcome. The quality of education received during undergraduate school may be linked to the quality of treatment provided in general dental practice. Objective: To compare the technical quality of RCT where rotary or manual step-back canal preparatory technique was employed in an undergraduate dental clinic in Turkey. Additionally, the present study aimed to compare radiographically commonly seen complications in both instrumentation systems. Materials and Methods: Dental records of 270 patients who received RCT undertaken by dental students were investigated by retrospective chart review. 565 root canals belonging to 270 patients were randomized into two groups [(rotary, n=280, and manual hand instruments, n=285)]. Root canal obturation was evaluated on the basis of the length of obturation being >2mm from the radiographic apex, with uniform radiodensity and good adaptation to root canal walls. Inadequate root canal obturation included cases containing procedural errors such as perforation, ledge, transportation, instrument separation. Descriptive statistics were used to define categorical variables (n, %) and the level of significance was set at 0.05. Results: The technical quality of RCT performed by undergraduate dental students was classified as 'adequate' in 75% and 53.7% of the cases, respectively for rotary and manual groups, respectively (p < 0.05). The highest procedural errors were seen in molars. Occurrence of procedural errors differed significantly between the groups, being 6.4% in rotary group and 12.3% in manual group (p = 0.017). However, occurrence of ledge formation was higher in manual group than that of rotary group (p = 0.007). Conclusion: In view of our findings, RCT performed by undergraduate dental students using rotary instrumentation systems is of higher technical quality and also has fewer procedural errors than manual instrumentation.
The prophylactic extraction of third molars is highly dependent on the surgeon’s experience as the common practices and guidelines contradict. The purpose of this study was to evaluate the eruption status of impacted third molars using deep learning-based artificial intelligence (AI) and to develop a model that predicts their final positions at an early stage to aid clinical decisions. In this retrospective study, 1102 panoramic radiographs (PANs) were annotated by three expert dentists to classify eruption status as either initial or definitive. A dataset was created and two deep learning architectures, InceptionV3 and ResNet50, were tested through a three-phase protocol: hyperparameter tuning, model evaluation, and assessment of preprocessing effects. Accuracy, recall, precision, and F1 score were used as performance metrics. Classical machine learning (ML) algorithms (SVM, KNN, and logistic regression) were also applied to features extracted from the deep models. ResNet50 with preprocessing achieved the best performance (F1 score: 0.829). Models performed better with definitive cases than with initial ones, where performance dropped (F1 score: 0.705). Clinically, the model predicted full eruption or impaction with 83% and 75% accuracy, respectively, but showed lower accuracy for partial impactions. These results suggest that AI can support early prediction of third molar eruption status and enhance clinical decision-making. Deep learning models (particularly ResNet50) demonstrated promising results in predicting third molar eruption outcomes. With larger datasets and improved optimization, AI tools may achieve greater accuracy and support routine clinical applications.
Objectives: Sinus lifting, a procedure to augment bone in the maxilla, may cause complications such as sinusitis due to impaired drainage. This study aimed to assess how sinus lifting impacts airflow in the sinus cavity, which is essential for patients undergoing dental implants. Using computational fluid dynamics (CFD), this research analyzed airflow changes after sinus floor elevation, offering insights into the aerodynamic consequences of the procedure. Methods: Digital modeling and CFD analysis were performed using patient cone-beam computed tomography data. Three different sinus elevation scenarios, each with varying implant heights, were simulated. Airflow simulations were conducted to assess how reshaping the sinus cavity affects aerodynamics and airflow dynamics. Nasal resistance, calculated through pressure drops and flow rates, and wall shear stress, indicating potential mucosal damage, were evaluated. Results: Although some airflow changes occurred post-surgery, the implants primarily affected the front and rear of the elevated area, with little impact being seen on air entry points. Conclusions: Maxillary sinus lifting for dental implant placement may impair sinus drainage, especially at higher elevations, increasing the risk of mucosal damage due to intensified airflows in the reduced sinus volume. A more uniform, simplified intra-sinus structure may enhance fluid dynamics and reduce complications.