Greg R. Luecke

Dr. Greg R. Luecke

orcid

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 March 2019 in Journal of Dynamic Systems, Measurement, and Control
Verified
Journal Article
Closed access
PDF file
SMSayani Maity
Sayani Maity
GLGreg R. Luecke
Greg R. Luecke
In this work, we study the dynamic response of the most popular unstable control problem, the inverted pendulum in terms of classical control theory. The theoretical and experimental results presented here explore the relationship between changes in the indirect tuning parameters from the linear quadratic regulator (LQR) design, and the final system performance effected using the feedback gains specified as the LQR weight constraints are changed. First, we review the development of the modern control approach using full state-feedback for stabilization and regulation, and present simulation and experimental comparisons as we change the optimization targets for the overall system and as we change one important system parameter, the length of the pendulum. Second, we explore the trends in the response by developing the generalized root locus for the system using incremental changes in the LQR weights. Next, we present a family of curves showing the local root locus and develop relationships between the weight changes and the system performance. We describe how these locus trends provide insight that is useful to the control designer during the effort to optimize the system performance. Finally, we use our general results to design an effective feedback controller for a new system with a longer pendulum and present experiment results that demonstrate the effectiveness of our analysis.

18 April 2018 in Sensors
Verified
Journal Article
Open access
PDF file
NTNazita Taghavi
Nazita Taghavi
GLGreg R. Luecke
Greg R. Luecke
NJNick D Jeffery
Nick D Jeffery
In this research, we describe a new balancing device used to stabilize the rear quarters of a patient dog with spinal cord injuries. Our approach uses inertial measurement sensing and direct leg actuation to lay a foundation for eventual muscle control by means of direct functional electrical stimulation (FES). During this phase of development, we designed and built a mechanical test-bed to develop the control and stimulation algorithms before we use the device on our animal subjects. We designed the bionic test-bed to mimic the typical walking gait of a dog and use it to develop and test the functionality of the balancing device for stabilization of patient dogs with hindquarter paralysis. We present analysis for various muscle stimulation and balancing strategies, and our device can be used by veterinarians to tailor the stimulation strength and temporal distribution for any individual patient dog. We develop stabilizing muscle stimulation strategies using the robotic test-bed to enhance walking stability. We present experimental results using the bionic test-bed to demonstrate that the balancing device can provide an effective sensing strategy and deliver the required motion control commands for stabilizing an actual dog with a spinal cord injury.

27 November 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
NTNazita Taghavi
Nazita Taghavi
GLGreg R. Luecke
Greg R. Luecke
NJNick D Jeffery
Nick D Jeffery
In this study, we present the experimental results demonstrating the functionality of our recently developed “balancing device” for walking restoration in patients with spinal cord injuries. Since we are preparing this device for testing on dogs, we program the analytical core of the device to recognize both stance and swing phases of the dog gait, the direction that the dog is falling, as well as selecting a suitable balancing strategy to prevent falling. The analytical core of the device is a commercial microcontroller, the Teensy, which is able to provide suitable stimulation commands and intensities as a voltage for delivery to the stimulation circuit and target muscles. We show the functional schematic of the device along with experimental results obtained by testing the device in a simulated robotic dog. Results show that the sensory system of the animal lost by spinal cord injury can be replaced by the sensing core of the device and the analytical core can provide appropriate stimulation control to balance the body of a dog. All test results are obtained using our robot test-bed and living animals are not involved in this study.

1 May 2019 in Computers and Electronics in Agriculture
Verified
Journal Article
Closed access
CMChase Meusel
Chase Meusel
CGChase Grimm
Chase Grimm
JSJordan Starkey
Jordan Starkey
SGStephen B. Gilbert
Stephen B. Gilbert
BGBrian Gilmore
Brian Gilmore
THTimothy Hunt
Timothy Hunt

10 March 2020 in Computers
Verified
Journal Article
Open access
PDF file
NTNazita Taghavi
Nazita Taghavi
GLGreg R. Luecke
Greg R. Luecke
NJNick D Jeffery
Nick D Jeffery
Development of an advanced electromechanical system requires a blend of technical expertise and knowledge, from electrical and mechanical engineering to software and system engineering. Engineers working in this field must be able to understand and analyze the interrelated electrical and mechanical components, as well as computer controlling programs, to communicate with each system part. In this paper, we aim to review the requirements and technical knowledge for development of these new technologies.

18 December 1998
Verified
Conference Paper
Closed access
GLGreg R. Luecke
Greg R. Luecke
NZNaci Zafer
Naci Zafer
Assembly operations require high speed and precision with low cost. The manufacturing industry has recently turned attenuation to the possibility of investigating assembly procedures using graphical display of CAD parts. For these tasks, some sort of feedback to the person is invaluable in providing a real sense of interaction with virtual parts. This research develops the use of a commercial assembly robot as the haptic display in such tasks. For demonstration, a peg-hole insertion task is studied. Kane's Method is employed to derive the dynamics of the peg and the contact motions between the peg and the hole. A handle modeled as a cylindrical peg is attached to the end effector of a PUMA 560 robotic arm. The arm is handle modeled as a cylindrical peg is attached to the end effector of a PUMA 560 robotic arm. The arm is equipped with a six axis force/torque transducer. The use grabs the handle and the user-applied forces are recorded. A 300 MHz Pentium computer is used to simulate the dynamics of the virtual peg and its interactions as it is inserted in the virtual hole. The computed torque control is then employed to exert the full dynamics of the task to the user hand. Visual feedback is also incorporated to help the user in the process of inserting the peg into the hole. Experimental results are presented to show several contact configurations for this virtually simulated task.