Ovidiu Buiga

Mr. Ovidiu Buiga


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2014 in Advances in Engineering Software
Verified
Journal Article
Closed access
OBOvidiu Buiga
Ovidiu Buiga
LTLucian Tudose
Lucian Tudose

28 March 2010 in Structural and Multidisciplinary Optimization
Verified
Journal Article
Closed access
PDF file
LTLucian Tudose
Lucian Tudose
OBOvidiu Buiga
Ovidiu Buiga
CŞCornel Ştefanache
Cornel Ştefanache
ASAndrás Sóbester
András Sóbester

21 October 2019 in Materials
Verified
Journal Article
Open access
PDF file
AMAvram Manea
Avram Manea
GBGrigore Baciut
Grigore Baciut
MBMihaela Baciut
Mihaela Baciut
DPDumitru Pop
Dumitru Pop
DCDan Sorin Comsa
Dan Sorin Comsa
Florin OnisorFlorin Onisor
Florin Onisor
Background: Once inserted and osseointegrated, dental implants become ankylosed, which makes them immobile with respect to the alveolar bone. The present paper describes the development of a new and original implant design which replicates the 3D physiological mobility of natural teeth. The first phase of the test followed the resistance of the implant to mechanical stress as well as the behavior of the surrounding bone. Modifications to the design were made after the first set of results. In the second stage, mechanical tests in conjunction with finite element analysis were performed to test the improved implant design. Methods: In order to test the new concept, 6 titanium alloy (Ti6Al4V) implants were produced (milling). The implants were fitted into the dynamic testing device. The initial mobility was measured for each implant as well as their mobility after several test cycles. In the second stage, 10 implants with the modified design were produced. The testing protocol included mechanical testing and finite element analysis. Results: The initial testing protocol was applied almost entirely successfully. Premature fracturing of some implants and fitting blocks occurred and the testing protocol was readjusted. The issues in the initial test helped design the final testing protocol and the new implants with improved mechanical performance. Conclusion: The new prototype proved the efficiency of the concept. The initial tests pointed out the need for design improvement and the following tests validated the concept.

22 November 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Simion HaragâşSimion Haragâş
Simion Haragâş
NRNinacs Roland
Ninacs Roland
OBOvidiu Buiga
Ovidiu Buiga
LTLucian Tudose
Lucian Tudose
AHAlexandru Haragâș
Alexandru Haragâș
FCFelicia Cristea
Felicia Cristea
The aim of this paper is to develop a mathematical model for an unconventional worm gear consisting of a globoid worm and a worm wheel where the teeth are bearings. Using rolling elements such the teeth of the worm wheel (ball bearings) transforms the sliding friction to rolling friction during the process of worm gear meshing, improving power. The geometry of the component elements of the gear is analyzed in correlation with its kinematics. After the creation of the mathematical model, it is validated both analytically (through complex graphic representations) and experimentally (by creating, for a particular case, the 3D model and the concrete physical model (prototype) of the gear through 3D printing).