Per- and polyfluorinated alkyl substances (PFASs) are ubiquitous environmental contaminants, present in the environment and in the human body. They have raised global concern because of their diffusion in the environment, particularly in water, causing cases of human overexposure due to consumption of contaminated drinking water. Human biomonitoring is the most effective way to characterize human exposure to PFASs, and it is important that as many labs as possible could easily perform this kind of analysis. Analytical methods for quantitation of PFAS mixtures in human serum have been developed, but most of them required materials that are not always easily available in all the laboratories. This paper describes a very simple and accessible HPLC MS/MS method of analysis and quantification of 13 perfluorocarboxylic acids and perfluorosulfonate compounds (belonging to the class of per- and polyfluorinated alkyl substances (PFASs)) in human serum. Method development data provide detailed descriptions of the optimization process in terms of sample preparation, laboratory analysis of human serum samples, determination of analytes by HPLC MS/MS, and describing the pump gradient time, working conditions, and acquisition.
This paper presents the results of the human biomonitoring of ten urinary OH-PAHs (hydroxylated polycyclic aromatic hydrocarbon) in a cohort of workers at an incinerator in Turin, Italy. Long-term exposure was assessed through repeated measurements at three time points: before the startup (T0), after 1 year (T1), and after 3 years (T2). Paired data were available for 26 subjects, seven administrative workers (AWs) and 19 plant workers (PWs). Short-term exposure was assessed by comparing start-end shift measurements. Due to the non-normal distribution of the data, the nonparametric Cuzick’s test for trend and the Wilcoxon signed-rank test for paired samples were used. Neither the trend nor the T0-T2 comparison tests resulted in statistically significant outputs in the two groups (q-value > 0.05), even when controlling for smoking habits. In relation to PWs, some of the metabolites were higher at T2 with respect to T0, but no linear increase was found. Conversely, 1-OH-PYR (ng/g creatinine) showed lower median values at T1 (61.5) and T2 (67) compared to the baseline (151.3). Similarly, short-term comparisons yielded no significant results, with rather overlapping distributions of values. Overall, no significant increases in metabolite levels were detected as a result of occupational exposure in the incinerator workers considered. These findings align with previous results for metals and ambient air measurements.