Measuring the state of a qubit is a key fundamental operation of a quantum computer. High-fidelity single-shot readout of superconducting qubits can be achieved using parametric amplifiers at millikelvin temperatures. However, scaling parametric amplifiers beyond hundreds of qubits is challenging due to practical size and power limitations. Nanobolometers can, in contrast, offer scalability, sensitivity and speed suitable for qubit readout. Here we show that a bolometer can provide single-shot qubit readout with a readout duration of 13.9 μs and a single-shot fidelity of 0.618. The fidelity is mainly limited by the energy relaxation time of the qubit (28 μs), and a fidelity of 0.927 is found after removing errors arising from this relaxation. In the future, higher-fidelity single-shot readout may be achieved through improvements in chip design and experimental setup, as well as a change in the bolometer absorber material to reduce the readout time to the level of hundreds of nanoseconds and below.
The Cooper pairs in superconducting condensates are shown to acquire a temperature-dependent dc magnetic moment under the effect of the circularly polarized electromagnetic radiation. The mechanisms of this inverse Faraday effect are investigated within the simplest version of the phenomenological dynamic theory for superfluids, namely, the time-dependent Ginzburg-Landau (GL) model. The light-induced magnetic moment is shown to be strongly affected by the nondissipative oscillatory contribution to the superconducting order parameter dynamics, which appears due to the nonzero imaginary part of the GL relaxation time. The relevance of the latter quantity to the Hall effect in the superconducting state allows us to establish the connection between the direct and inverse Faraday phenomena.
The urgent need for reliable simulation tools to match the extreme accuracy needed to control tailored quantum devices highlights the importance of understanding open quantum systems and their modeling. To this end, we compare here the commonly used Redfield and Lindblad master equations against numerically exact results in the case of one and two resonant qubits transversely coupled at a single point to a Drude-cut ohmic bath. All the relevant parameters are varied over a broad range, which allows us to give detailed predictions about the validity and physically meaningful applicability of the weak-coupling approaches. We characterize the accuracy of the approximate approaches by comparing the maximum difference of their system evolution superoperators with numerically exact results. After optimizing the parameters of the approximate models to minimize the difference, we also explore if and to what extent the weak-coupling equations can be applied at least as phenomenological models. Optimization may lead to an accurate reproduction of experimental data, but yet our results are important to estimate the reliability of the extracted parameter values such as the bath temperature. Our findings set general guidelines for the range of validity of the usual Born-Markov master equations and indicate that they fail to accurately describe the physics in a surprisingly broad range of parameters, in particular, at low temperatures. Since quantum-technological devices operate there, their accurate modeling calls for a careful choice of methods.
We propose a quantum-circuit refrigerator (QCR) based on photon-assisted quasiparticle tunneling through a single normal-metal–insulator–superconductor (NIS) junction. In contrast to previous studies with multiple junctions and an additional charge island for the QCR, we directly connect the NIS junction to an inductively shunted electrode of a superconducting microwave resonator making the device immune to low-frequency charge noise. At low characteristic impedance of the resonator and parameters relevant to a recent experiment, we observe that a semiclassical impedance model of the NIS junction reproduces the bias voltage dependence of the QCR-induced damping rate and frequency shift. For high characteristic impedances, we derive a Born–Markov master equation and use it to observe significant non-linearities in the QCR-induced dissipation and frequency shift. We further demonstrate that, in this regime, the QCR can be used to initialize the linear resonator into a non-thermal state even in the absence of any microwave drive.
The known quantum error-correcting codes are typically built on approximative open-quantum-system models such as Born-Markov master equations. However, it is an open question how such codes perform in actual physical systems that, to some extent, necessarily exhibit phenomena beyond the limits of these models. To this end, we employ numerically exact open-quantum-system dynamics to analyze the performance of a five-qubit error-correction code where each qubit is coupled to its own bath. We first focus on the performance of a single error-correction cycle covering timescales and coupling strengths beyond those of Born-Markov models. We observe distinct power-law behavior of the error-corrected channel infidelity : in the ultrashort times and in the short-time range , where is the cutoff angular frequency of the bath. Furthermore, the observed scaling of the performance of error correction is found to be robust against various imperfections in physical qubit systems, such as perturbations in qubit-qubit coupling strengths and parametric disorder. For repeated error correction, we demonstrate the breaking of the five-qubit error-correction code and of the Born-Markov models if the repetition rate of the error-correction cycles exceeds or the coupling strength , where is the angular frequency of the qubit. Our results provide bounds of validity for the standard quantum error-correction codes and pave the way for applying numerically exact open-quantum-system methods for further studies of error correction beyond simple error models and for other strongly coupled many-body models.