Andreia Cristina Fonseca Alves

Dr. Andreia Cristina Fonseca Alves

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2020 in Journal of Cleaner Production
Verified
Journal Article
Closed access
RARomario Victor Pacheco Antero
Romario Victor Pacheco Antero
AAAndreia Cristina Fonseca Alves
Andreia Cristina Fonseca Alves
SOSergio Botelho de Oliveira
Sergio Botelho de Oliveira
SOSatu Anneli Ojala
Satu Anneli Ojala
SBSarah Silva Brum
Sarah Silva Brum

25 June 2019 in Environmental Science and Pollution Research
Verified
Journal Article
Closed access
PDF file
AAAndreia Cristina Fonseca Alves
Andreia Cristina Fonseca Alves
RARomario Victor Pacheco Antero
Romario Victor Pacheco Antero
SOSergio Botelho de Oliveira
Sergio Botelho de Oliveira
SOSatu Anneli Ojala
Satu Anneli Ojala
Paulo Sérgio ScalizePaulo Sérgio Scalize
Paulo Sérgio Scalize

17 April 2019 in Chemical Engineering Communications
Verified
Journal Article
Closed access
RARomario Victor Pacheco Antero
Romario Victor Pacheco Antero
AAAndreia Cristina Fonseca Alves
Andreia Cristina Fonseca Alves
PSPaulo de Tarso Ferreira Sales
Paulo de Tarso Ferreira Sales
SOSergio Botelho de Oliveira
Sergio Botelho de Oliveira
SOSatu Anneli Ojala
Satu Anneli Ojala
SBSarah Silva Brum
Sarah Silva Brum
The worrying hydric crisis and the increasing water contamination by emerging pollutants around the world stimulate the development of activated carbons (AC) for the removal of endocrine disruptors, including bisphenol-A (BPA). For this reason, a new approach for the synthesis of AC from hydrochar produced through hydrothermal carbonization (HTC) of Brazilian Cerrado biomass (Magonia pubescens–Sapindaceae) and physical activation using water vapor is highlighted. Compared to the traditional method of physical activation after pyrolysis, HTC was found to be better option to develop the specific surface area, porosity, and yield of the ACs, which presented mesoporous structure and carbon content higher than 80%. The BPA adsorption was evaluated by varying the contact time, BPA concentration, and pH. The Langmuir, Freundlich, and Redlich–Peterson isotherms were used to model the adsorption behavior. In the preliminary test to verify the adsorption efficiency, the AC obtained from hydrochar treated at 180 °C presented better results compared to commercial AC. The BPA adsorption data of the best treated hydrochar correlated well with the pseudo first-order model and the Langmuir isotherm (Qmax = 21.26 mg g−1). The results of the studies indicated the combination of HTC and physical activation with steam to be an efficient way to prepare an ecologically sound adsorbent for removal of Bisphenol-A from water with lower temperature and without chemical reagents. The ACs obtained can also be potential materials for other applications, such as in the field of catalysis and environmental remediation.

17 August 2023 in Chemengineering
Verified
Journal Article
Open access
PDF file
LFLucas B. de Faria
Lucas B. de Faria
GTGuilhermina Ferreira Teixeira
Guilhermina Ferreira Teixeira
AAAndreia Cristina Fonseca Alves
Andreia Cristina Fonseca Alves
Jose Joaquin Linares LeonJose Joaquin Linares Leon
Jose Joaquin Linares Leon
SOSergio de Oliveira
Sergio de Oliveira
FCFlavio Colmati
Flavio Colmati
This work presents the electrochemical degradation of the herbicide Diuron by anodic oxidation on a Ti/Ru0.3Ti0.7O2 metal mixed oxide anode using sulfate as the electrolyte. The study includes the influence of Diuron concentration and current density on anodic oxidation. The results evidence a first-order degradation, with the highest capacity achieved at 40 mA cm−2 and at an initial Diuron concentration of 38 mg L−1. Nevertheless, in terms of efficiency and energy demand, the operation at 10 mA cm−2 is favored due to the more efficient and less energy-consuming condition. To discern the optimum design and operation conditions, this work presents the results of a preliminary technical–economic analysis, demonstrating that, to minimize the total costs of the system, it is recommended to seek the most efficient conditions, i.e., the conditions demanding the lowest applied charges with the highest Diuron degradation. At the same time, attention must be given to the required cell voltage to not increase excessively the operating costs.

7 May 2024 in International Journal of Environmental Science and Technology
Verified
Journal Article
Closed access
PDF file
AAAndreia Cristina Fonseca Alves
Andreia Cristina Fonseca Alves
JBJ. G. Barbosa
J. G. Barbosa
SOS. B. de Oliveira
S. B. de Oliveira
PSP. S. Scalize
P. S. Scalize

25 July 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
LFLucas B. De Faria
Lucas B. De Faria
GTGuilhermina Ferreira Teixeira
Guilhermina Ferreira Teixeira
AAAndreia Cristina Fonseca Alves
Andreia Cristina Fonseca Alves
Jose Joaquin Linares LeonJose Joaquin Linares Leon
Jose Joaquin Linares Leon
SOSergio de Oliveira
Sergio de Oliveira
FCFlavio Colmati
Flavio Colmati
This work presents the electrochemical degradation of the herbicide Diuron by anodic oxidation on a Ti/Ru0.3Ti0.7O2 dimensionally stable anode (DSA) using sulfate as electrolyte. The study includes the influence of the Diuron concentration and the current density on the anodic oxidation. The results evidence a first-order degradation, with the highest degradation capacity achieved at 40 mA cm2 and an initial Diuron concentration of 38 mg L1. Nevertheless, in terms of efficiency and energy demand, the operation at 10 mA cm2 is favored due to the more efficient and less energy-consuming condition. To discern the optimum design and operation conditions, this work presents the results of a preliminary technical-economical analysis, demonstrating that, to minimize the total costs of the system, it is recommended to seek the most efficient conditions, i.e., the conditions demanding the lowest applied charges with the highest Diuron degradation. At the same time, attention must be given to the required cell voltage to not increase excessively the operating costs.