Restrictive requirements for maximum concentrations of metals introduced into the environment lead to search for effective methods of their removal. Chemical precipitation using hydroxides or sulfides is one of the most commonly used methods for removing metals from water and wastewater. The process is simple and inexpensive. However, during metal hydroxide precipitation, large amounts of solids are formed. As a result, metal hydroxide is getting amphoteric and it can go back into the solution. On the other hand, use of sulfides is characterized by lower solubility compared with that of metal hydroxides, so a higher degree of metal reduction can be achieved in a shorter time. Disadvantages of that process are very low solubility of metal sulfides, highly sensitive process to the dosing of the precipitation agent, and the risks of emission of toxic hydrogen sulfide. All these restrictions forced to search for new and effective precipitants. Potassium/sodium thiocarbonate (STC) and 2,4,6-trimercaptotiazine (TMT) are widely used. Dithiocarbamate (DTC) compounds are also used, e.g., sodium dimethyldithiocarbamate (SDTC), and ligands for permanent metal binding, e.g., 1,3-benzenediamidoethanethiol (BDETH2), 2,6-pyridinediamidoethanethiol (PyDET), a pyridine-based thiol ligand (DTPY) or ligands with open chains containing many sulfur atoms, using of a tetrahedral bonding arrangement around a central metal atom. The possibility of improving the efficiency of metal precipitation is obtained by using a higher dose of precipitating agent. However, toxic byproducts are often produced. It is required that the precipitation agents not only effectively remove metal ions from the solution but also effectively bind with dyes or metal complexes.
Pollution of the aquatic environment with microplastics has recently been recognised as a new environmental threat considering their negative impact on the ecosystem. Due to the low density and small particle size of microplastics, they are easily discharged into sewage systems and wastewater treatment plants. Thus, wastewater treatment plants are considered major sources of microplastic pollution in aquatic and terrestrial environments. Therefore, there is an urgent need for an in-depth understanding of the occurrence, behaviour, and fate of microplastics in wastewater treatment plants before they are discharged into natural water bodies. This paper comprehensively reviews the current state of knowledge on the characteristics and removal of microplastics in a series of wastewater treatment plants by comparing their removal efficiency in different unit processes, both during pretreatment, biological treatment, and tertiary treatment. The study found varying efficiencies in wastewater treatment technologies, with the first stage of treatment removing between 16.5 and 98.4% of microplastics, while during biological treatment the overall efficiency of microplastics removal ranges from 78.1 to 99.9% (membrane bioreactor). Nevertheless, given the large volumes of wastewater continuously discharged to receiving bodies, even tertiary treatment plants can be a significant source of microplastics in surface waters. The largest fraction of MPs removed in conventional wastewater treatment plants is trapped in the sludge. Among the critical treatment technologies, microplastic quantitative analysis showed that membrane bioreactors and filter-based treatment technologies have the highest microplastic removal efficiency. Based on a review of the existing literature, it was concluded that existing wastewater treatment plants are ineffective in removing microplastics completely, and there is a risk that they could be discharged into surrounding water sources.
1 June 2016 in Ecological Chemistry and Engineering S
Adenosine-5’-triphosphate (ATP) is a high-energy molecule playing a role of universal energy carrier used in cell metabolism. Since ATP is present in both prokaryotic and eukaryotic cells, this coenzyme can be used to determine a hygiene state. During last decade there has been a significant growth of practical applications of ATP measurements. ATP tests are commonly used for an assessment of hygienic conditions in food industry, residential buildings and hotels. In comparison with traditional and time-consuming laborious microbial analysis the measurement of ATP provides a quick indicative on-site data, characterizing microbial and organic contamination to support decision-making with regards to adequate corrective and preventive actions. This paper demonstrates applications of ATP in practice and, particularly, in water treatment technology and wastewater processing. The review highlights opportunities for using the test for the optimization of water treatment facilities and pipe networks functioning in order to assess wastewater toxicity and wastewater treatment process efficiency. Other areas of application are also addressed. The review of literature indicates that ATP used in different areas of industry can be considered as a diagnostic method - complement the classical methods - useful for identification of hygiene risks as well as a tool for a real-time management of health and environmental risks.
1 January 2016 in Environment Protection Engineering