JiaYu Xia

Mr. JiaYu Xia

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 January 2011 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JXJiaYu Xia
JiaYu Xia
NSNell Sedransk
Nell Sedransk
XFXingdong Feng
Xingdong Feng
In the Addona et al. paper (Nature Biotechnology 2009), a large-scale multi-site study was performed to quantify Multiple Reaction Monitoring (MRM) measurements of proteins spiked in human plasma. The unlabeled signature peptides derived from the seven target proteins were measured at nine different concentration levels, and their isotopic counterparts were served as the internal standards. In this paper, the sources of variation are analyzed by decomposing the variance into parts attributable to specific experimental factors: technical replicates, sites, peptides, transitions within each peptide, and higher-order interaction terms based on carefully built mixed effects models. The factors of peptides and transitions are shown to be major contributors to the variance of the measurements considering heavy (isotopic) peptides alone. For the light (12C) peptides alone, in addition to these factors, the factor of study*peptide also contributes significantly to the variance of the measurements. Heterogeneous peptide component models as well as influence analysis identify the outlier peptides in the study, which are then excluded from the analysis. Using a log-log scale transformation and subtracting the heavy/isotopic peptide [internal standard] measurement from the peptide measurements (i.e., taking the logarithm of the peak area ratio in the original scale establishes that), the MRM measurements are overall consistent across laboratories following the same standard operating procedures, and the variance components related to sites, transitions and higher-order interaction terms involving sites have greatly reduced impact. Thus the heavy peptides have been effective in reducing apparent inter-site variability. In addition, the estimates of intercepts and slopes of the calibration curves are calculated for the sub-studies. The MRM measurements are overall consistent across laboratories following the same standard operating procedures, and heavy peptides can be used as an effective internal standard for reducing apparent inter-site variability. Mixed effects modeling is a valuable tool in mass spectrometry-based proteomics research.

9 January 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JQJin Qilin
Jin Qilin
QHQingbang Han
Qingbang Han
JQJianhua Qian
Jianhua Qian
LSLiujia Sun
Liujia Sun
KGKao Ge
Kao Ge
JXJiaYu Xia
JiaYu Xia
Drainage pipeline construction projects are vulnerable to a range of defects, such as branch concealed joints, variable diameter, two pipe mouth significances, foreign object insertion, pipeline rupture, and pipeline end disconnection, generated during long-term service in a complex environment. This paper proposes two enhancements to multiple attention learning to detect and segment multiple defects. Firstly, we collected numerous samples of drainage pipeline sonar defect videos. Then, our multiple attention segmentation network was used for target segmentation. The test precision and accuracy of MAP@50 reach 96.0% and 90.9%, respectively, in the segmentation prediction. Compared to the coordinate attention and convolutional block attention module attention models, it had a significant precision advantage, and the weight file size is merely 7.0 MB, which is far smaller than the Yolov9 model segmentation weight size. The multiple attention method proposed in this paper was adopted for detection, instance segmentation, and pose detection in different public datasets, especially in the object detection of the coco128-seg dataset under the same condition. Map@50:95 has increased by 13.0% assisted by our multiple attention mechanism. The results indicated the memory efficiency and high precision of the integration of the multiple attention model on several public datasets.


15 September 2026 in Sensors
Verified
Journal Article
Open access
PDF file
YHYao Huang
Yao Huang
QHQingbang Han
Qingbang Han
JWJin-Huan Wang
Jin-Huan Wang
KGKao Ge
Kao Ge
NSNa-Na Su
Na-Na Su
JXJiaYu Xia
JiaYu Xia
The regular inspection of underground sewer pipelines is essential for maintaining their functionality and supporting sustainable urban development. While optical sensors lack reliability, sonar imagery typically suffers from low contrast and severe noise, which is compounded by the constrained computational resources of remotely operated vehicles (ROVs). To address these limitations, this paper develops LSD-DETR, which is a lightweight Transformer-based detector for sewer pipe defects that balances accuracy and computational efficiency. First, Sonar-DualNet organizes CSP-based and HGNetV2-based blocks into a shared-stem heterogeneous backbone to reduce duplicated shallow computation while preserving complementary representations. Second, DR-Fusion performs content-adaptive modulation and aggregation of the two heterogeneous branches. In addition, the original CCFM and AIFI modules are replaced by a GLSA-enhanced BiFPN and the HiLo attention mechanism, respectively, as task-oriented adaptations for efficient cross-scale and local–global feature modeling. Experiments on the UPSD dataset show that LSD-DETR achieves an mAP50 of 89.6% and an mAP50:95 of 54.3%. Relative to RT-DETR-R18, these results represent improvements of 2.0 and 1.6 percentage points, respectively, while reducing the parameter count by 42.7% and FLOPs by 58.4%. The results demonstrate a favorable accuracy–complexity trade-off for forward-looking sonar defect detection in underground sewer pipelines.