Anna Pastuszczak

Dr. Anna Pastuszczak


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 July 2018 in Optics Express
Verified
Journal Article
Closed access
PDF file
KCKrzysztof Czajkowski
Krzysztof Czajkowski
APAnna Pastuszczak
Anna Pastuszczak
RKRafał Kotyński
Rafał Kotyński
We present a closed-form image reconstruction method for single-pixel imaging based on the generalized inverse of the measurement matrix. Its numerical cost scales proportionally with the number of measured samples. Regularization of the inverse problem is obtained by minimizing the norms of the convolution between the reconstructed image and a set of spatial filters. The final reconstruction formula can be expressed in terms of matrix pseudoinverse. At high compression, this approach is an interesting alternative to the methods of compressive sensing based on l1-norm optimization, which are too slow for real-time applications. For instance, we demonstrate experimental single-pixel detection with real-time reconstruction obtained in parallel with measurement at a frame rate of 11 Hz for highly compressive measurements with a resolution of 256 × 256. To this end, we preselect the sampling functions to match the average spectrum obtained with an image database. The sampling functions are selected from the Walsh-Hadamard basis, from the discrete cosine basis, or from a subset of Morlet wavelets convolved with white noise. We show that by incorporating the quadratic criterion into the closed-form reconstruction formula, we can use binary rather than continuous sampling and reach similar reconstruction quality as is obtained by minimizing the total variation. This makes it possible to use cosine- or Morlet-based sampling with digital micromirror devices without advanced binarization methods.

11 January 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
KCKrzysztof Czajkowski
Krzysztof Czajkowski
APAnna Pastuszczak
Anna Pastuszczak
RKRafał Kotyński
Rafał Kotyński
Single-pixel imaging is an indirect imaging technique which utilizes simplified optical hardware and advanced computational methods. It offers novel solutions for hyper-spectral imaging, polarimetric imaging, three-dimensional imaging, holographic imaging, optical encryption and imaging through scattering media. The main limitations for its use come from relatively high measurement and reconstruction times. In this paper we propose to reduce the required signal acquisition time by using a novel sampling scheme based on a random selection of Morlet wavelets convolved with white noise. While such functions exhibit random properties, they are locally determined by Morlet wavelet parameters. The proposed method is equivalent to random sampling of the properly selected part of the feature space, which maps the measured images accurately both in the spatial and spatial frequency domains. We compare both numerically and experimentally the image quality obtained with our sampling protocol against widely-used sampling with Walsh-Hadamard or noiselet functions. The results show considerable improvement over the former methods, enabling single-pixel imaging at low compression rates on the order of a few percent.

7 June 2022 in Optics Express
Verified
Journal Article
Closed access
RSRafał Stojek
Rafał Stojek
APAnna Pastuszczak
Anna Pastuszczak
PWPiotr Wróbel
Piotr Wróbel
RKRafał Kotyński
Rafał Kotyński
The usually reported pixel resolution of single pixel imaging (SPI) varies between 32 × 32 and 256 × 256 pixels falling far below imaging standards with classical methods. Low resolution results from the trade-off between the acceptable compression ratio, the limited DMD modulation frequency, and reasonable reconstruction time, and has not improved significantly during the decade of intensive research on SPI. In this paper we show that image measurement at the full resolution of the DMD, which lasts only a fraction of a second, is possible for sparse images or in a situation when the field of view is limited but is a priori unknown. We propose the sampling and reconstruction strategies that enable us to reconstruct sparse images at the resolution of 1024 × 768 within the time of 0.3s. Non-sparse images are reconstructed with less details. The compression ratio is on the order of 0.4% which corresponds to an acquisition frequency of 7Hz. Sampling is differential, binary, and non-adaptive, and includes information on multiple partitioning of the image which later allows us to determine the actual field of view. Reconstruction is based on the differential Fourier domain regularized inversion (D-FDRI). The proposed SPI framework is an alternative to both adaptive SPI, which is challenging to implement in real time, and to classical compressive sensing image recovery methods, which are very slow at high resolutions.

25 January 2011 in Applied Physics A
Verified
Journal Article
Open access
PDF file
RKRafał Kotyński
Rafał Kotyński
TSTomasz Stefaniuk
Tomasz Stefaniuk
APAnna Pastuszczak
Anna Pastuszczak
We demonstrate numerically the diffraction-free propagation of sub-wavelength sized optical beams through simple elements built of metal-dielectric multilayers. The proposed metamaterial consists of silver and a high refractive index dielectric, and is designed using the effective medium theory as strongly anisotropic and impedance matched to air. Further it is characterised with the transfer matrix method, and investigated with FDTD. The diffraction-free behaviour is verified by the analysis of FWHM of PSF in the function of the number of periods. Small reflections, small attenuation, and reduced Fabry–Pérot resonances make it a flexible diffraction-free material for arbitrarily shaped optical planar elements with sizes of the order of one wavelength.

15 April 2011 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
APAnna Pastuszczak
Anna Pastuszczak
RKRafał Kotyński
Rafał Kotyński
We optimize the effective skin-depth and resolution of Ag-TiO2, Ag-SrTiO3, and Ag-GaP multilayers for imaging with sub-wavelength resolution. In terms of transmission and resolution, the optimized multilayers outperform simple designs based on combined use of effective medium theory, impedance matching and Fabry–Perot resonances. For instance, an optimized Ag-GaP multilayer consisting of only 17 layers, operating at the wavelength of 490 nm and having a total thickness equal to one wavelength, combines 78% intensity transmission with a resolution of 60 nm. It is also shown that use of the effective medium theory leads to sub-optimal multilayer designs with respect to the trade-off between the skin depth and resolution already when the period of the structure is on the order of 40 nm or larger.

3 August 2021 in Optics Express
Verified
Journal Article
Closed access
APAnna Pastuszczak
Anna Pastuszczak
RSRafał Stojek
Rafał Stojek
PWPiotr Wróbel
Piotr Wróbel
RKRafał Kotyński
Rafał Kotyński
The speed and quality of single-pixel imaging (SPI) are fundamentally limited by image modulation frequency and by the levels of optical noise and compression noise. In an approach to come close to these limits, we introduce a SPI technique, which is inherently differential, and comprises a novel way of measuring the zeroth spatial frequency of images and makes use of varied thresholding of sampling patterns. With the proposed sampling, the entropy of the detection signal is increased in comparison to standard SPI protocols. Image reconstruction is obtained with a single matrix-vector product so the cost of the reconstruction method scales proportionally with the number of measured samples. A differential operator is included in the reconstruction and following the method is based on finding the generalized inversion of the modified measurement matrix with regularization in the Fourier domain. We demonstrate 256 × 256 SPI at up to 17 Hz at visible and near-infrared wavelength ranges using 2 polarization or spectral channels. A low bit-resolution data acquisition device with alternating-current-coupling can be used in the measurement indicating that the proposed method combines improved noise robustness with a differential removal of the direct current component of the signal.