Shazzad Sharif Rassel

Dr. Shazzad Sharif Rassel

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 August 2021 in Nanoscale
Verified
Journal Article
Closed access
PDF file
FFFahim Al Fattah
Fahim Al Fattah
AKAsif Abdullah Khan
Asif Abdullah Khan
HAHossein Anabestani
Hossein Anabestani
MRMasud Rana
Masud Rana
SRShazzad Sharif Rassel
Shazzad Sharif Rassel
DBDayan Ban
Dayan Ban
Classification of device structures and applications of self-powered ultraviolet photodetectors.

11 February 2020 in The Analyst
Verified
Journal Article
Closed access
PDF file
SRShazzad Sharif Rassel
Shazzad Sharif Rassel
CXChao Xu
Chao Xu
SZSteven Zhang
Steven Zhang
DBDayan Ban
Dayan Ban
The contribution of QCL in detecting blood glucose levels noninvasively by midinfrared and photoacoustic spectroscopy.

16 January 2026 in Chemosensors
Verified
Journal Article
Open access
PDF file
TATasnim Ahmed
Tasnim Ahmed
KMKhan Mahmud
Khan Mahmud
MKMD Rejvi Kaysir
MD Rejvi Kaysir
SRShazzad Sharif Rassel
Shazzad Sharif Rassel
DBDayan Ban
Dayan Ban
Diabetes is a developing global health concern that cannot be cured, necessitating frequent blood glucose monitoring and dietary management. Photoacoustic Spectroscopy (PAS) in the mid-infrared (MIR) region has recently emerged as a viable noninvasive blood glucose monitoring technique. However, MIR-PAS confronts significant challenges: (i) Water absorption, which reduces light penetration, and (ii) interference from other blood components. This paper systematically analyzes the background of photoacoustic signal generation and proposes a differential PAS (DPAS) in the MIR region for removing the background signals arising from water and other interfering components of blood, which improves the overall detection sensitivity. A detailed mathematical model with an explanation for choosing two suitable MIR quantum cascade lasers for this differential scheme is presented here. For single-wavelength PAS (SPAS), a detection sensitivity of 1.537 µPa mg−1 dL was obtained from the proposed model. Alternatively, 2.333 µPa mg−1 dL detection sensitivity was found by implementing the DPAS scheme, which is about 1.5 times higher than SPAS. Moreover, DPAS facilitates an additional parameter, a differential phase shift between two laser responses, that has an effective correlation with the glucose concentration variation. Thus, MIR-based DPAS could be an effective way of monitoring blood glucose levels noninvasively in the near future.

16 April 2025 in Biosensors
Verified
Journal Article
Open access
PDF file
TZTHASIN MOHAMMAD ZAMAN
THASIN MOHAMMAD ZAMAN
MKMD Rejvi Kaysir
MD Rejvi Kaysir
SRShazzad Sharif Rassel
Shazzad Sharif Rassel
DBDayan Ban
Dayan Ban
Noninvasive blood glucose monitoring is crucial for diabetes management, and photoacoustic spectroscopy (PAS) offers a promising solution by detecting glucose levels through human skin. However, weak acoustic signals in PAS systems require optimized resonator designs for enhanced detection sensitivity. Designing such resonators physically is complex, requiring the precise identification of critical parameters before practical implementation. This study focused on optimizing a T-shaped photoacoustic resonator using finite element modeling in a COMSOL Multiphysics environment. By systematically varying the geometric design parameters of the T-cell resonator, a maximum increase in the pressure amplitude of 12.76 times with a quality factor (Q-factor) of 47.5 was achieved compared to the previously designed reference acoustic resonator. This study took a significant step forward by identifying key geometric parameters that influence resonator performance, paving the way for more sensitive and reliable noninvasive glucose monitoring systems.

10 May 2026 in ACS Omega
Verified
Journal Article
Open access
TPTanmoy Kumar Paul
Tanmoy Kumar Paul
SNSiam Sadik Nayem
Siam Sadik Nayem
ARAbdur Rakib
Abdur Rakib
JIJahirul Islam
Jahirul Islam
MKMD Rejvi Kaysir
MD Rejvi Kaysir
SRShazzad Sharif Rassel
Shazzad Sharif Rassel
Diabetes is a widespread metabolic disease in which the body’s inability to regulate blood glucose levels leads to severe health complications. Current limitations in noninvasive glucose sensing make finger-prick glucometers the standard for personal monitoring despite their discomfort and challenges for frequent measurements. By combining machine learning techniques with transmittance spectroscopy, this study presents a noninvasive approach for estimating BGL in personal healthcare. The system employs multispectral transmittance measurements at 650, 808, and 940 nm to evaluate glucose concentrations in aqueous solutions. Simulation of light absorption in skin layers and in vitro experiments identified 940 nm as the optimal wavelength, offering high sensitivity with minimal interference from water absorption. Using this wavelength, an in vivo system based on transmittance spectroscopy was developed for noninvasive glucose measurement. A machine learning pipeline incorporating ensemble models was implemented to predict glucose levels from optical data. Trained on 200 clinical samples obtained from the in vivo experimental setup, the XGBoost model outperformed other algorithms, achieving an R2 score of 0.94 with a root-mean-squared error (RMSE) of 23.92 mg/dL. The Clarke error grid analysis (CEGA) showed that 92.5% of predictions fell within Zone A and 7.5% within Zone B, with no samples in the critical zones (C–E), demonstrating the system’s robustness. These results highlight the potential of the proposed method as a practical, low-cost, and reliable solution for continuous noninvasive glucose monitoring in diabetes management.

26 March 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
TZTHASIN MOHAMMAD ZAMAN
THASIN MOHAMMAD ZAMAN
MKMD Rejvi Kaysir
MD Rejvi Kaysir
SRShazzad Sharif Rassel
Shazzad Sharif Rassel
DBDayan Ban
Dayan Ban
Noninvasive blood glucose monitoring is crucial for diabetes management, and photoacoustic spectroscopy (PAS) offers a promising solution by detecting glucose levels through the human skin. However, weak acoustic signals in PAS systems require optimized resonator designs for enhanced detection sensitivity. Designing such resonators physically is complex, requiring precise identification of critical parameters before practical implementation. This study focuses on optimizing a T-shaped photoacoustic resonator using finite element modeling in a COMSOL Multiphysics environment. By systematically varying the geometric design parameters of the T-cell resonator, a maximum increase in pressure amplitude of 12.76 times with a quality factor (Q-factor) of 47.5 was achieved to the previously designed reference acoustic resonator. This study takes a significant step forward by identifying key geometric parameters that influence resonator performance, paving the way for more sensitive and reliable noninvasive glucose monitoring systems.