Wenbin Du

Prof. Wenbin Du

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 January 2021 in ACS Catalysis
Verified
Journal Article
Closed access
YCYinglu Cui
Yinglu Cui
YCYanchun Chen
Yanchun Chen
XLXinyue Liu
Xinyue Liu
SDSaijun Dong
Saijun Dong
YTYu’e Tian
Yu’e Tian
BWBian Wu
Bian Wu

15 May 2009 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
WDWenbin Du
Wenbin Du
LLLiang Li
Liang Li
KNKevin P. Nichols
Kevin P. Nichols
RIRustem F. Ismagilov
Rustem F. Ismagilov
The SlipChip is a microfluidic device designed to perform multiplexed microfluidic reactions without pumps or valves. The device has two plates in close contact. The bottom plate contains wells preloaded with many reagents; in this paper plates with 48 reagents were used. These wells are covered by the top plate that acts as a lid for the wells with reagents. The device also has a fluidic path, composed of ducts in the bottom plate and wells in the top plate, which is connected only when the top and bottom plate are aligned in a specific configuration. Sample can be added into the fluidic path, filling both wells and ducts. Then, the top plate is “slipped”, or moved, relative to the bottom plate so the complementary patterns of wells in both plates overlap, exposing the sample-containing wells of the top plate to the reagent-containing wells of the bottom plate, and enabling diffusion and reactions. Between the two plates, a lubricating layer of fluorocarbon was used to facilitate relative motion of the plates. This paper implements this approach on a nanoliter scale using devices fabricated in glass. Stability of preloaded solutions, control of loading, and lack of cross-contamination were tested using fluorescent dyes. Functionality of the device was illustrated viacrystallization of a model membrane protein. Fabrication of this device is simple and does not require a bonding step. This device requires no pumps or valves and is applicable to resource-poor settings. Overall, this device should be valuable for multiplexed applications that require exposing one sample to many reagents in small volumes. One may think of the SlipChip as an easy-to-use analogue of a preloaded multi-well plate, or a preloaded liquid-phase microarray.

1 July 2010 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
FSFeng Shen
Feng Shen
WDWenbin Du
Wenbin Du
JKJason E. Kreutz
Jason E. Kreutz
AFAlice Fok
Alice Fok
RIRustem F. Ismagilov
Rustem F. Ismagilov
This paper describes a SlipChip to perform digital PCR in a very simple and inexpensive format. The fluidic path for introducing the sample combined with the PCR mixture was formed using elongated wells in the two plates of the SlipChip designed to overlap during sample loading. This fluidic path was broken up by simple slipping of the two plates that removed the overlap among wells and brought each well in contact with a reservoir preloaded with oil to generate 1280 reaction compartments (2.6 nL each) simultaneously. After thermal cycling, end-point fluorescence intensity was used to detect the presence of nucleic acid. Digital PCR on the SlipChip was tested quantitatively by using Staphylococcus aureus genomic DNA. As the concentration of the template DNA in the reaction mixture was diluted, the fraction of positive wells decreased as expected from the statistical analysis. No cross-contamination was observed during the experiments. At the extremes of the dynamic range of digital PCR the standard confidence interval determined using a normal approximation of the binomial distribution is not satisfactory. Therefore, statistical analysis based on the score method was used to establish these confidence intervals. The SlipChip provides a simple strategy to count nucleic acids by using PCR. It may find applications in research applications such as single cell analysis, prenatal diagnostics, and point-of-care diagnostics. SlipChip would become valuable for diagnostics, including applications in resource-limited areas after integration with isothermal nucleic acid amplification technologies and visual readout.

8 April 2011 in Analytical Chemistry
Verified
Journal Article
Closed access
FSFeng Shen
Feng Shen
EDElena K. Davydova
Elena K. Davydova
WDWenbin Du
Wenbin Du
JKJason E. Kreutz
Jason E. Kreutz
OPOlaf Piepenburg
Olaf Piepenburg
RIRustem F. Ismagilov
Rustem F. Ismagilov

13 October 2011 in Journal of the American Chemical Society
Verified
Journal Article
Closed access
FSFeng Shen
Feng Shen
BSBing Sun
Bing Sun
JKJason E. Kreutz
Jason E. Kreutz
EDElena K. Davydova
Elena K. Davydova
WDWenbin Du
Wenbin Du
RIRustem F. Ismagilov
Rustem F. Ismagilov

4 November 2008 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
DCDelai Chen
Delai Chen
WDWenbin Du
Wenbin Du
YLYing Liu
Ying Liu
WLWeishan Liu
Weishan Liu
AKAndrey Kuznetsov
Andrey Kuznetsov
RIRustem F. Ismagilov
Rustem F. Ismagilov
Microelectrodes enable localized electrical stimulation and recording, and they have revolutionized our understanding of the spatiotemporal dynamics of systems that generate or respond to electrical signals. However, such comprehensive understanding of systems that rely on molecular signals—e.g., chemical communication in multicellular neural, developmental, or immune systems—remains elusive because of the inability to deliver, capture, and interpret complex chemical information. To overcome this challenge, we developed the “chemistrode,” a plug-based microfluidic device that enables stimulation, recording, and analysis of molecular signals with high spatial and temporal resolution. Stimulation with and recording of pulses as short as 50 ms was demonstrated. A pair of chemistrodes fabricated by multilayer soft lithography recorded independent signals from 2 locations separated by 15 μm. Like an electrode, the chemistrode does not need to be built into an experimental system—it is simply brought into contact with a chemical or biological substrate, and, instead of electrical signals, molecular signals are exchanged. Recorded molecular signals can be injected with additional reagents and analyzed off-line by multiple, independent techniques in parallel (e.g., fluorescence correlation spectroscopy, MALDI-MS, and fluorescence microscopy). When recombined, these analyses provide a time-resolved chemical record of a system's response to stimulation. Insulin secretion from a single murine islet of Langerhans was measured at a frequency of 0.67 Hz by using the chemistrode. This article characterizes and tests the physical principles that govern the operation of the chemistrode to enable its application to probing local dynamics of chemically responsive matter in chemistry and biology.