Muhammad Abrar Afzal

Mr. Muhammad Abrar Afzal

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 March 2024 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MSMadiha Sharif
Madiha Sharif
MLMushtaq Lashari
Mushtaq Lashari
UFUmer Farooq
Umer Farooq
MIMusadiq Idris
Musadiq Idris
MAMuhammad Abrar Afzal
Muhammad Abrar Afzal
The study was designed to ascertain the diagnostic efficacy of hand-held digital refractometer in determining total protein (TP). The Sipli sheep (n = 128) were grouped as per gender (females = 99, males = 29) and age (G1 = up till 1 year, n = 35; G2 = from 1 to 2 years, n = 63; G3 = above 2 years, n = 30). The results regarding the overall mean (±SE) values for the TPs attained through serum chemistry analyzer (TP1) and hand-held digital refractometer (TP2) were non-significantly (P≥0.05) different (59.2±1.6g/L and 59.8±0.5g/L, respectively). However, the reference intervals (RIs) were quite different for the two TPs being 45.1–95.7g/L and 57.0–67.0g/L for TP1 and TP2, respectively. Similar results were seen for gender-wise and group-wise results. On the contrary, the results regarding correlation coefficient and logilinear regression showed a negative correlation between the two TPs (r = -0.0244) with an adjusted r-square of 0.059 (5.9% probability). Furthermore, the three tests implied to assess the level of agreement between the two methods (Cronbach alpha, Intraclass correlation coefficient, and Bland & Altman test) revealed least agreement between the two methods. In a nutshell, the results of TP through digital refractometer were not in concordance with those attained through serum chemistry analyzer. However, it can cautiously be used if these results are compared with relevant corrected RIs.

20 September 2023 in Tropical Animal Health and Production
Verified
Journal Article
Closed access
PDF file
UFUmer Farooq
Umer Farooq
MIMusadiq Idris
Musadiq Idris
NSNouman Sajjad
Nouman Sajjad
MAMuhammad Abrar Afzal
Muhammad Abrar Afzal

24 July 2024 in Advancements in Life Sciences
Verified
Journal Article
Closed access
PDF file
MCMaryam Ch
Maryam Ch
UFUmer Farooq
Umer Farooq
MIMusadiq Idris
Musadiq Idris
MLMushtaq Hussain Lashari
Mushtaq Hussain Lashari
SQSaira Qasim
Saira Qasim
AAAsad Ali
Asad Ali
Background: The dried blood spot (DBS) technique using filter papers has revolutionized the conventional blood sampling techniques through ease of blood collection, storage and transport. Various analytes (such as hormones, antigens, antibodies and hematochemical attributes) are being estimated through DBS globally. However, this technique has not yet been implied in Pakistan. This research work is the first of its kind regarding hemoglobin (Hb) estimation in Cholistani cattle (n=63) blood through DBS technique using filter paper.Methods: Three methods of Hb estimation were implied in the present study viz. through veterinary hematology analyzer (HbA), and two indirect cyanmethemoglobin methods (HbIC and HbICX) using measured (20µL) and unmeasured blood drops on the filter paper, respectively.Results: Results revealed that HbA and HbIC were non-significantly (P≥0.05) different from each other, being different from HbICX (P≤0.05). The HbICX gave overestimated values of Hb as compared to HbA and HbIC. The sensitivity, specificity, positive predictive value, and negative predictive value for HbIC were higher being 86.1%, 88.3%, 88.0%, and 86.0%, respectively as compared to the lower values of 45.0%, 12.0%, 12.0% and 45.0%, for HbICX. Bland and Altman test revealed a better level of agreement between HbA and HbIC. Around the mean difference line, there was no proportional bias in data distribution (Mean= -0.16, 95% CI= 0.34 to -0.67). Similarly, measures attained through Cronbach alpha and intraclass correlation coefficient between HbA and HbIC were higher being 0.703 and 0.825 values for single and average, respectively, as compared to the values of 0.200 and 0.333 between HbA and HbICX.Conclusion: It is concluded that the indirect cyanmethemoglobin method for Hb estimation is reliable and accurate for cattle blood, if a measured quantity of blood drop is taken on a filter paper. We recommend this DBS technique for Hb estimation in cattle blood for resource-poor settings and for livestock herds being reared distantly from the laboratories. For future, it is recommended that DBS technique with various other modifications and for other hematochemical biomarkers may be validated for livestock blood.Keywords: Dried blood spot; Hemoglobin; Cholistani cattle

17 November 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
MIMusadiq Idris
Musadiq Idris
UFUmer Farooq
Umer Farooq
MLMushtaq Lashari
Mushtaq Lashari
MAMuhammad Abrar Afzal
Muhammad Abrar Afzal
JTJunaid Tariq
Junaid Tariq
MCMaryam Ch
Maryam Ch
The present study was designed with the objective of assessing the potential of size of dried blood spot (DBS) on a filter paper in predicting hematological attributes viz. RBC count, Hb, PCV and total protein (TP) in Cholistani cattle blood (n=71). A measured drop of blood was placed carefully on Whatman 42 filter paper and size was measured using ImageJ software. Results revealed that Hb had significant (P≤0.05) relation with size of the DBS. The regression equation between Hb and size of DBS was used to deduce corrected Hb (CHb). The determined Hb and CHb were non-significantly (P≥0.05) different and had a strong agreement. It is concluded that the size of DBS is a substantially reliable predictor of Hb in cattle blood.