Background: Malignant hyperthermia (MH) is a pharmacogenetic disorder of skeletal muscle triggered by certain anesthetic agents. While Ryanodine Receptor 1 (RYR1) and Calcium Voltage-Gated Channel Subunit Alpha1 S (CACNA1S) are well-established susceptibility genes, the complete genetic basis of MH remains unclear, particularly in Asian populations. Methods: We conducted gene panel testing targeting 24 calcium-related genes in 338 individuals from 247 Japanese families with suspected or confirmed MH. Variants were analyzed on a gene-by-gene basis, and their pathogenicity was assessed using in silico prediction tools. Additionally, patients were classified into subgroups based on the results of the calcium-induced calcium release (CICR) assay and the Clinical Grading Scale (CGS) score. Results: Candidate pathogenic variants were identified in 118 families (48.2%), including 73 (29.8%) in RYR1, 16 (6.5%) in CACNA1S, and 62 (25.3%) in other genes. Among CICR-positive families, RYR1 and CACNA1S variants were detected in 42.0% and 5.3% of cases, respectively. In individuals with high CGS scores (Ranks 5–6), RYR1 and CACNA1S variants were observed in 56.0% and 12.0%, respectively. Variants in other genes such as STAC3, CASQ1, ATP2A1, ASPH, HRC and TRPV1 were also detected. Conclusions: Our findings confirm the predominant role of RYR1 and CACNA1S in MH susceptibility in the Japanese population and highlight additional candidate genes that may contribute to the condition. Broader genetic screening and functional validation studies are warranted to further elucidate the polygenic nature of MH.
In order to study the aging characteristics of oil-paper insulation, and thus providing reliable basis for condition assessment of transformer insulation, in this paper, we carried out accelerated thermal aging test in Laboratory environment and researched the polarization/depolarization current of samples by using time domain dielectric spectroscopy. Then, we proposed an algorithm for improving time domain dielectric spectroscopy by wavelet transform theory. The results show that time domain dielectric spectroscopy can reflect the overall polarization processes of oil-paper insulation and as the aging time increases, the peak value of the dielectric spectroscopy increases. The improved wavelet transform algorithm can effectively improve the time domain dielectric spectrum, thus the main polarization processes of oil-paper insulation is clearly shown in the time domain dielectric spectroscopy. Peaks' value and time of improved time domain dielectric spectroscopy correspond to the intensity and responding speed of different polarization processes, and peaks value has a good linear relationship with aging times which can be used to quantitatively assess the aging condition of different part of oil-paper insulation.
Background/Objectives: Airway management techniques, including mask ventilation and tracheal intubation, are vital across medical settings. However, these procedures can be challenging, especially when environmental conditions are less than ideal. This study explores how the height of the operating table affects the difficulty of anesthesia techniques involving mask ventilation and tracheal intubation. Methods: Twenty anesthesiologists participated in this study. We assessed the difficulty of procedures such as mask ventilation, Macintosh laryngoscopy, and video laryngoscopy using McGRATH and AWS, on a four-level scale. The operating table’s height was adjusted at four points: the operator’s umbilicus, the inferior margin of the 12th rib, the xiphoid process, and the nipple. Results: Mask ventilation was easiest at the operating table’s height aligned with the inferior margin of the 12th rib. Conversely, direct laryngoscopic exposure was perceived as easier at higher table heights, with nipple height being optimal. The McGRATH laryngoscopy showed consistent difficulty across table heights, whereas the AWS tended to be somewhat more difficult at greater heights. Conclusions: The optimal bed height for video laryngoscopy coincided with that for mask ventilation. Video laryngoscopy offers enhanced flexibility in optimal patient positioning compared to Macintosh laryngoscopy, contributing to its advantages in tracheal intubation procedures.
Background/Objectives: Airway management techniques, including mask ventilation and tracheal intubation, are vital across medical settings. However, these procedures can be challenging, especially when environmental conditions are less than ideal. This study explores how the height of the operating table affects the difficulty of surgical procedures involving mask ventilation and tracheal intubation. Methods: Twenty anesthesiologists participated in this study. We assessed the difficulty of procedures- such as mask ventilation, Macintosh laryngoscopy, and video laryngoscopy with McGRATH and AWS- on a four-level scale. The operating table’s height was adjusted at four points: operator's umbilicus, inferior margin of the 12th rib, xiphoid process, and nipple. Results: Mask ventilation was easiest at the operating table’s height aligned with the inferior margin of the 12th rib. Conversely, direct laryngoscopic exposure was perceived easier at higher table heights, with nipple height being optimal. McGRATH laryngoscopy showed consistent difficulty across table height, whereas AWS tended to be somewhat more difficult at greater heights. Conclusions: The optimal bed height for video laryngoscopy coincided with that for mask ventilation. Video laryngoscopy offers enhanced flexibility in optimal patient positioning compared to Macintosh laryngoscopy, contributing to its advantages in tracheal intubation procedures.