Bo Wu

Bo Wu


Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2021 in Journal of Cleaner Production
Verified
Journal Article
Closed access
SJSi-Min Jian
Si-Min Jian
BWBo Wu
Bo Wu
NHNan Hu
Nan Hu

15 June 2021 in Advances in Structural Engineering
Verified
Journal Article
Closed access
PDF file
HZHaiyan Zhang
Haiyan Zhang
KWKeyue Wan
Keyue Wan
BWBo Wu
Bo Wu
ZHZhonghao Hu
Zhonghao Hu
Geopolymer recycled aggregate concrete (GRAC) is a new green construction material, which uses geopolymer as the binder and recycled concrete as aggregates. To compare the flexural performance of GRAC and ordinary recycled aggregate concrete (RAC) beams, static loading tests were conducted on seven GRAC beams and three RAC beams. The effects of the replacement ratio of recycled aggregates (RAs), the replacement patterns, and the reinforcement ratio on the flexural behavior of GRAC beams are evaluated. The test data show that the replacement ratio has no significant effect on the cracking pattern, failure mode, or bending capacity of GRAC beams, but the replacement pattern does have an effect. Under a given replacement ratio, replacing only the larger fraction of natural aggregates (NA) with RA improves the concrete strength and crack resistance of both RAC and GRAC beams, compared to that using same replacement percentage for all fractions. Due to the lower elastic modulus and strength of GRAC prepared in this study, the GRAC beams have lower height of neutral axis and greater deflection than RAC beams at the same load level and possess slightly lower cracking load, bending capacity, and ductility. The bending capacity of GRAC beams can be predicted by the formulas proposed for ordinary reinforced concrete beams in the Chinese code GB50010-2010, ACI 318-11, or BS EN 1992-1-1:2004 codes, but the safety margin is generally lower than that of ordinary reinforced concrete beams.

1 August 2007 in Advances in Structural Engineering
Verified
Journal Article
Closed access
BWBo Wu
Bo Wu
ZHZhou Hong
Zhou Hong
GTGui-He Tang
Gui-He Tang
CWChao Wang
Chao Wang
Calculation of the fire resistance of 480 square cross section normal strength concrete (NSC) columns and 480 high strength concrete (HSC) columns, made with siliceous aggregate, is presented in this paper. The variables considered in the study include concrete strength (NSC and HSC), dimension of column cross section, axial load ratio, load eccentricity ratio (i.e., ratio of load eccentricity to dimension of column cross section), and steel ratio (i.e., ratio of longitudinal reinforcement to cross-sectional area of column). Explosive spalling of HSC exposed to fire is also considered approximately. Simulation results show that: (1) increasing the dimension of column cross section, reducing the axial load ratio, and reducing the load eccentricity ratio are all effective measures for improving the fire resistance of both NSC and HSC columns subjected to concentric axial load or eccentric axial load; (2) increasing the steel ratio has no significant influence on the fire resistance of concentrically loaded NSC and HSC columns, but has some positive effect on the fire resistance of eccentrically loaded NSC and HSC columns; (3) explosive spalling of HSC has a significant detrimental influence on the fire resistance of HSC columns. Based on simulation results, a simplified formula is empirically developed to enable determination of the fire resistance of both NSC and HSC columns, and is shown to be applicable to concrete columns with square cross section.

1 January 2012 in Advanced Materials Research
Verified
Journal Article
Closed access
PDF file
Yu XuYu Xu
Yu Xu
BWBo Wu
Bo Wu
MJMing Jiang
Ming Jiang
XHXin Huang
Xin Huang
Reinforced Concrete (RC) beams in the building structures are usually assumed as a ‘T’-shaped beam when the effects of adjacent slab flange are considered. However, experimental studies on residual flexural behavior of ‘T’-shaped RC beams are rarely reported. The residual flexural behavior of two RC rectangular beams and one RC ‘T’-shaped beam after exposure to ISO834 standard fire were experimentally investigated in the paper. The detailed experimental results, including the measured temperatures, flexural capacity, load-deflection curves and concrete strain are presented. The effects of flange on temperature distribution and residual flexural behavior of RC beams were analyzed. The experimental results show that: (a) the assumption of plane section is applicable for RC ‘T’-shaped beam. (b) The flexural capacity of RC rectangular beam was decreased 18.5% after exposure to fire for 2 hours, but the ultimate mid-span deflection was increased 55.1%. (c) The residual flexural capacity and the ultimate mid-span deflection of RC rectangular beam after fire was respectively increased 8.4% and 9.9% due to the effect of flange.

26 September 2019 in Materials
Verified
Journal Article
Open access
PDF file
Yong YuYong Yu
Yong Yu
BWBo Wu
Bo Wu
In the past decade, directly reusing large pieces of coarsely crushed concrete (referred to as demolished concrete lumps or DCLs) with fresh concrete in new construction was demonstrated as an efficient technique for the recycling of waste concrete. Previous studies investigated the mechanical properties of recycled lump concrete (RLC) containing different sizes of DCLs; however, for actual application of this kind of concrete, little information is known about the influence of the spatial locations of DCLs and coarse aggregates on the concrete strength. Moreover, the mechanical responses of such a concrete containing various shapes of DCLs are also not well illustrated. To add knowledge related to these topics, two-dimensional mesoscale simulations of RLC containing DCLs under axial compression were performed using the discrete element method. The main variables of interest were the relative strength of the new and old concrete, the distribution of the lumps and other coarse aggregates, and the shape of the lumps. In addition, the differences in compression behavior between RLC and recycled aggregate concrete were also predicted. The numerical results indicate that the influence tendency of the spatial locations of DCLs and coarse aggregate pieces on the compressive stress–strain curves for RLC is similar to that of the locations of coarse aggregates for ordinary concrete. The strength variability of RLC is generally higher than that of ordinary concrete, regardless of the relative strength of the new and old concrete included; however, variability has no monotonic trend with an increase in the lump replacement ratio. The mechanical properties of RLC in compression are little influenced by the geometric shape of DCLs as long as the ratio of the length of their long axis to short axis is smaller than 2.0. The compressive strength and elastic modulus of RLC are always superior to those of recycled aggregate concrete designed with a conventional mixing method.

1 April 2013 in Journal of Structural Engineering
Verified
Journal Article
Closed access
IHIvy Fung-Yuen Ho
Ivy Fung-Yuen Ho
ELEddie Siu-Shu Lam
Eddie Siu-Shu Lam
BWBo Wu
Bo Wu
YWYa-Yong Wang
Ya-Yong Wang
In this study, a method of strengthening circular columns using high-performance ferrocement (HPF) is proposed. This is achieved by replacing the concrete cover by HPF (i.e., comprising rendering material and wire mesh). Direct tensile tests were carried out on HPF specimens. For rendering material with high tensile strength, it is necessary to incorporate its tensile strength in the estimation of the tensile strength of HPF. Nineteen full-scale circular plain or RC columns were tested under monotonic compression. Eleven were detailed with a volumetric ratio of transverse reinforcement ρs at 0.230%. HPF, having three different rendering materials and with one or three layers of wire mesh, was used to confine eight of these columns. Test variables included volume fraction of wire mesh and tensile strength of rendering material. Plain-concrete columns strengthened with HPF have peak strengths at 30–59% higher than control specimens. RC columns having a low ρs at 0.230% and strengthened with HPF can achieve peak strengths comparable with columns having a high ρs at 0.918%. A set of empirical equations for predicting the peak strength of plain-concrete or RC columns strengthened with HPF is derived, showing good agreement with the test data. Lastly, a design procedure for strengthening a RC column by replacing the concrete cover using HPF is proposed.