The application of 225Ac (half-life T1/2 = 9.92 d) dramatically reduces the activity used for peptide receptor radionuclide therapy by a factor of 1000 in comparison to 90Y, 177Lu or 188Re while maintaining the therapeutic outcome. Additionally, the range of alpha particles of 225Ac and its daughter nuclides in tissue is much lower (47–85 μm for alpha energies Eα = 5.8–8.4 MeV), which results in a very precise dose deposition within the tumor. DOTA-conjugated commercially available peptides used for endoradiotherapy, which can readily be labeled with 177Lu or 90Y, can also accommodate 225Ac. The benefits are lower doses in normal tissue for the patient, dose reduction of the employees and environment and less shielding material. The low availability of 225Ac activity is preventing its application in clinical practice. Overcoming this barrier would open a broad field of 225Ac therapy. Independent which production pathway of 225Ac proves the most feasible, the use of automated synthesis and feasible and reproducible patient doses are needed. The Modular-Lab EAZY is one example of a GMP-compliant system, and the cassettes used for synthesis are small. Therefore, also the waste after the synthesis can be minimized. In this work, two different automated setups with different purification systems are presented. In its final configuration, three masterbatches were performed on the ML EAZY for DOTA-TATE and PSMA-I&T, respectively, fulfilling all quality criteria with final radiochemical yields of 80–90% for the 225Ac-labeled peptides.
(1) Background: Targeted alpha therapy is an emerging field in nuclear medicine driven by two advantages: overcoming resistance in cancer-suffering patients to beta therapies and the practical application of lower activities of 212Pb- and 225Ac-labelled peptides to achieve the same doses compared to beta therapy due to the highly cytotoxic nature of alpha particles. However, quality control of the 212Pb/225Ac-radiopharmaceuticals remains a challenge due to the low activity levels used for therapy (100 kBq/kg) and the formation of several free daughter nuclides immediately after the formulation of patient doses; (2) Methods: The routine alpha detection on thin-layer chromatograms (TLC) of 212Pb- and 225Ac-labelled peptides using a MiniScanPRO+ scanner combined with an alpha detector head was compared with detection using an AR-2000 scanner equipped with an open proportional counter tube. Measurement time, resolution and validity were compared for both scanners; (3) Results: For 225Ac, the quality control values of the radiochemical purity (RCP) were within the acceptance criteria 2 h after TLC development, regardless of when the TLC probe was taken. That is, if the TLC probe was taken 24 h after radiosynthesis, the true value of the RCP was not measured until 5 h after TLC development. For 212Pb-labelled peptides, the probe sampling did not have a high impact on the value of the RCP for the MiniScanPRO+ and AR-2000. A difference was observed when measuring TLC with the AR-2000 in different modes; (4) Conclusions: The MiniScanPRO+ is fast, does not require additional equipment and can also measure the gamma spectrum, which may be important for some radiopharmaceutical production sites and regulatory authorities. The AR-2000 has a better signal-to-noise ratio, and this eliminates the need for additional waiting time after TLC development.
This work investigates the proposed enhanced efficacy of photodynamic therapy (PDT) by activating photosensitizers (PSs) with Cherenkov light (CL). The approaches of Yoon et al. to test the effect of CL with external radiation were taken up and refined. The results were used to transfer the applied scheme from external radiation therapy to radionuclide therapy in nuclear medicine. Here, the CL for the activation of the PSs (psoralen and trioxsalen) is generated by the ionizing radiation from rhenium-188 (a high-energy beta-emitter, Re-188). In vitro cell survival studies were performed on FaDu, B16 and 4T1 cells. A characterization of the PSs (absorbance measurement and gel electrophoresis) and the CL produced by Re-188 (luminescence measurement) was performed as well as a comparison of clonogenic assays with and without PSs. The methods of Yoon et al. were reproduced with a beam line at our facility to validate their results. In our studies with different concentrations of PS and considering the negative controls without PS, the statements of Yoon et al. regarding the positive effect of CL could not be confirmed. There are slight differences in survival fractions, but they are not significant when considering the differences in the controls. Gel electrophoresis showed a dominance of trioxsalen over psoralen in conclusion of single and double strand breaks in plasmid DNA, suggesting a superiority of trioxsalen as a PS (when irradiated with UVA). In addition, absorption measurements showed that these PSs do not need to be shielded from ambient light during the experiment. An observational test setup for a PDT nuclear medicine approach was found. The CL spectrum of Re-188 was measured. Fluctuating inconclusive results from clonogenic assays were found.
(1) Background: As the demand for 212Pb for clinical theranostics rises, empirical studies that examine the radiation safety implications of different 224Ra sources are needed to facilitate discussions with local authorities for the translation of 203/212Pb theranostics routine clinical practice. (2) Methods: Environmental 220Rn (Thoron) emanation was detected by a RAD7 detector in the vicinity of respective 212Pb sources and additional alpha-dosimeters to detect 220Rn during generator elution, radiosynthesis, and quality control. Personnel gamma exposure was measured using whole-body and ring dosimeters. Generators included those based on wet-chemical-process- and emanation-based technology. (3) Results: During generator handling, varying levels of 220Rn were observed in the vicinity of generators. An additional monthly whole-body dose must be considered when handling different sources of 212Pb generators, and this depends upon local shielding and the handling approaches toward use of the technology. (4) Conclusions: 224Ra in any form (including radionuclide generators) should always be handled within a fume hood to keep potential contamination and exposure to personnel as low as reasonably achievable. Following standard practices of radiation safety, generators of 212Pb can be used safely for theranostic applications.
(1) Background: Targeted alpha therapy is a new emerging field in nuclear medicine driven by the two advantages of overcoming resistance of cancer-suffering patients against beta therapies and practically application of lower activities of 212Pb- and 225Ac-labelled peptides to reach the same doses compared to beta therapy due to the high cytotoxic nature of alpha particles. Quality control of the 212Pb/225Ac-radiopharmaceuticals remains a challenge due to the low activity levels used for therapy (100 kBq/kg) and the formation of several free daughter nuclides immediately after formulation of patient doses; (2) Methods: The routine alpha detection of thin-layer chromatograms (TLC) of 212Pb- and 225Ac-labelled peptides using a MiniScanPRO+ scanner combined with an alpha detector head was compared with detection using an AR-2000 scanner equipped with an open proportional counter tube. Measurement time, resolution and validity were compared for both scanners; (3) Results: For 225Ac quality control the values of RCP are within the acceptance criteria 2 h after TLC development, regardless of when the TLC probe was taken. If the TLC probe was taken 24 h after radiosynthesis, the true value of RCP within the acceptance criteria was not measured until 5 h after TLC development. For 212Pb-labelled peptides, the probe sampling did not have a high impact on the value of RCP for the MiniScanPRO+ and AR-2000. A difference was observed when measuring the TLC with the AR-2000 in different modes; (4) Conclusions: The MiniScanPRO+ is fast, does not require additional equipment and can also measure the gamma spectrum, which may be important for some radiopharmaceutical production sites and regulatory authorities. The AR-2000 has a better signal-to-noise ratio and this eliminates the need for additional waiting time after TLC development.