Climate and urban environment changes lead to tropical building adaptation and resilient strategy. They focus especially on thermal comfort and noise propagation variation as the result of global warming and urban growth. This study analyzes a conceptual design of tropical urban model on integrated design of thermal and acoustic (thermoacoustic) issues. By experimental measurement and simulation method using Computational Fluid Dynamics, the findings are directed to meet the standards and to recommend the new guidelines for sustainable urban building. The research location is in Surabaya as the urban tropical lowland area and Eco-House of ITS, a tropical building model in an urban environment, was built as experiment model. The results highlighted that the noise barrier should consider 5.24% of the maximum window to wall ratio (WWR) in tree dimensionally analysis, horizontally and vertically. Providing vertical ventilation is the best solution for urban density, but the orientation and its flanking noise affect the passive cooling. In general, there are some factors having a high contribution in addition to WWR, such as wind acceleration, the distance, and building material.
The urban building standards recommend adaptable shift on heat and noise criteria as the main issues related to the high-density environment. The previous studies relating to building thermal comfort provided the comparison results between the past and recent conditions. This study reviews the guidelines and regulations of international standard, overseas countries, and specific region of tropical climate research in Indonesia. The evaluation is focused on tropical climate in order to reach the accurate thermal comfort and noise criteria comparison for Indonesia. Furthermore, the field study of the 71 of the tropical built environment respondents was also conducted in order to update and compare to the existing standards. The review results show that compared to 17°C to 31°C thermal comfort range from the World Health Organization, the tropical thermal comfort should be determined with a range of 29.3°C to 31°C. Based on the field studies, for lowland is formulated by 1.4x+29.3 and in highland is 1.5x+29.3 as two representative regions of the tropical environment. For noise criteria, some countries set the policy for determining noise limits which has the same value between day and night condition as the result of the constant number of noise source with the similar level of annoyance. Based on the field study, this study updates the noise criteria which the denser environment, lowland, has limits of noise in 49.9 dBA when in highland is 47.8 dBA. Both of them are lower than 55 dBA of Indonesian Standard. Noise perception by occupants in nighttime shows that both in the lowland and in the highland, the vote is lower than daytime. The noise limits are 45.9 dBA and 40.0 dBA for lowland and highland, respectively. In general, the updated standard completes the existing and the detail of Indonesia national standard and the will be useful to guide the tropical building design.
27 April 2018 in International Journal of Technology
A science that deals with the transformation of electrical energy into acoustic energy or vice versa, electroacoustic, generates the increased intensity and loudness of sound by mechanical and/or electrical means. Because of the same context, it should be designed simultaneously with the consideration of room acoustics. A vertical building is usually designed separately with architectural aspect and other technical consideration. Interior mezzanine has unique characteristic on propagating sound because its balconies could be an element of room acoustic reflector and absorber, a shelter from noise and a barrier of sound propagation. For optimum music and speech activities, hybrid design strategy of active strategy using electroacoustic combined with the passive method is conducted. This research optimizes room acoustics criteria of variated building models as integrated building system with the loudspeaker. Ecotect Analysis and additional audio programming determine all process by simulating all potential variables. The result shows that 5 m will be the recommended minimum distance of column-loudspeaker placement for mezzanine floor. With the same loudspeaker specification power and frequency, the vertical structure as the armature of electroacoustic orientation and interior material are the most critical variables in determining of reverberation time optimization.
1 April 2021 in IOP Conference Series: Earth and Environmental Science
An urban environment leads to tropical building adaptation by providing sufficient thermal comfort and energy efficiency. For generating the physiological cooling, interconnected attribute of site cluster permeability is translated into lower context such as building scale to provide optimal wind speed to restore thermal comfort. It will be expected to find the critical factor which most influences the performance. Meanwhile, the encoding of the space connectivity to accelerate air movement has been evaluated by previous studies. In this paper, the counter reading of visibility relationships analysis on computational fluid dynamics is conducted and decoded by DepthmapX simulation. The site clusters type of grid, cul-de-sac, and the open area plan of a loop represent housing estates in some tropical regions as the cases. The results highlighted that 50% or more translated air movement from the site to the building scale environment is determined by the dominated warmest connectivity of open space. The potency of energy efficiency is indicated by the capability of accommodating both social connectivity and environmental performance. Furthermore, the code of irregular building patterns by increasing air movement has low spatial and social connectivity because of space depthless. Providing open space for site planning encourages both environmental and social qualities.
16 March 2018 in IOP Conference Series: Earth and Environmental Science
Under the situation of an urban environment, noise has been a critical issue in affecting the indoor environment. A reliable approach is required for evaluation of the community noise as one factor of anthrophonic in the urban environment. This research investigates the level of noise exposure from different community noise sources and elaborates the advantage of the noise disadvantages for soundscape innovation. Integrated building element design as a protector for noise control and speech intelligibility compliance using field experiment and MATLAB programming and modeling are also carried out. Meanwhile, for simulation analysis and building acoustic optimization, Sound Reduction-Speech Intelligibility and Reverberation Time are the main parameters for identifying tropical building model as case study object. The results show that the noise control should consider its integration with the other critical issue, thermal control, in an urban environment. The 1.1 second of reverberation time for speech activities and noise reduction more than 28.66 dBA for critical frequency (20 Hz), the speech intelligibility index could be reached more than fair assessment, 0.45. Furthermore, the environmental psychology adaptation result "Close The Opening" as the best method in high noise condition and personal adjustment as the easiest and the most adaptable way.
16 March 2018 in IOP Conference Series: Earth and Environmental Science
Many previous types of research have discussed the permeability of site cluster. Because of interaction and interconnected attribute, it will be better that there is its translation into lower context such as building and interior scale. In this paper, the sustainability design performance of both similar designs of courtyard and atrium are investigated continuing the recommendation of site space permeability. By researching related literature review and study through Ecotect Analysis and Ansys Fluent simulations, the pattern transformation and optimum courtyard and atrium design could comply the requirement. The results highlighted that the air movement from the site could be translated at the minimum of 50% higher to the building and indoor environment. Thus, it has potency for energy efficiency when grid, loop, and cul-de-sac site clusters, with 25% of ground coverage, have connectivity with building courtyard compared to the atrium. Energy saving is higher when using low thermal transmittance of transparent material and its lower area percentages for the courtyard walls. In general, it was more energy efficient option as part of a low rise building, while the courtyard building performed better with increasing irregular building height more than 90% of the difference.