Background: The artificial urinary sphincter has been an effective treatment for stress urinary incontinence caused by intrinsic sphincter deficiency in women. However, the use of this device has been limited by the technical difficulties and risks associated with the open implantation procedure. Preliminary studies using robotic techniques have shown promising results, but only one small study has compared robotic to open procedures. This study aims to compare the outcomes of robotic and open artificial urinary sphincter implantation in women with stress urinary incontinence due to intrinsic sphincter deficiency in a large multicenter cohort. Methods: Data were collected retrospectively from female patients who underwent open or robot-assisted artificial urinary sphincter implantation from 2006 to 2020 at 12 urology departments. The primary outcome was the rate of complications within 30 days after surgery, graded using the Clavien-Dindo Classification. Perioperative and functional outcomes were compared between the two groups. Results: A total of 135 patients were included, with 71 in the robotic group and 64 in the open group. The open group had a higher rate of intraoperative complications (27.4% vs. 12.7%; p = 0.03) and postoperative complications (46.8% vs. 15.5%; p < 0.0001). More patients in the robotic group achieved full continence (83.3% vs. 62.3%; p = 0.01). The open group had higher explantation (27.4% vs. 1.4%; p < 0.0001) and revision rates (17.5% vs. 5.6%; p = 0.02). The estimated 1-year explantation-free survival rate was higher in the robotic group. (98.6% vs. 78.3%; p = 0.001). Conclusions: Robot-assisted implantation may reduce perioperative morbidity and improve functional outcomes compared to open implantation in women with stress urinary incontinence.
31 December 2024 in International Neurourology Journal
Purpose: While pump manipulation is rarely problematic in male patients with artificial urinary sphincters (AUSs), the situation may differ in female patients due to anatomical or cultural factors. This study aimed to evaluate the prevalence of difficulties in pump manipulation among female AUS patients, identify associated risk factors, and explore management strategies for this challenging issue.Methods: Data were collected from all female patients who underwent a robotic AUS implantation at a single academic center between 2014 and 2022. The primary endpoint was temporary difficulties, defined by at least one other short hospitalization to learn pump manipulation.Results: Out of the 88 female AUS patients included in the study, 20 experienced initial difficulties manipulating the pump, accounting for 22.7% of the group. Temporary difficulties were reported by 16 patients (18.2%), while 4 patients (4.5%) had their devices permanently deactivated. Surgical reoperations to reposition the pump were necessary for 5 patients, representing 5.6% of the sample. The only variables significantly associated with temporary difficulties were longer operative time (183.4 minutes vs. 159.1 minutes, P=0.04) and the overall experience of the center (32 vs. 50, P=0.04). The sole variable significantly linked to serious difficulties was the overall experience of the center (11 vs. 47, P=0.004). Although the median age and body mass index were higher in the group with temporary difficulties, these differences were not statistically significant.Conclusions: Difficulties in manipulating the pump are relatively common among female AUS patients. Most of these difficulties can be resolved through repeated patient education and careful follow-up. However, some may lead to serious complications. Raising awareness of this issue, along with ongoing patient education and meticulous follow-up, may help to minimize these consequences.
Purpose: Previous studies suggested better functional outcomes and longer device survival for female artificial urinary sphincter (AUS) implantation compared to male AUS implantation. We hypothesized that the adoption of robotic approaches for female implantation might have influenced these comparisons. This study aimed to compare the outcomes of robotic female AUS and male AUS implantation for non-neurogenic stress urinary incontinence (SUI). Methods: We retrospectively reviewed charts of male patients who had AUS implantation and female patients who underwent robotic AUS implantation for non-neurogenic SUI between 2010 and 2022 at a single center. Prior AUS implantations were exclusion criteria. The primary endpoint was continence status at 3 months, categorized as complete resolution of SUI (0 pad), improved SUI (1pad), or unchanged SUI (>1pad). Results: After excluding 79 patients, 171 were included: 70 women and 101 men. Operative time was shorter in males (126.9 vs. 165.5 min; p < 0.0001). Postoperative complication rates were similar (17.3% vs. 22.9%; p = 0.38). Continence status at 3 months and last follow-up favored females. The ICIQ-SF decrease at 3 months was greater in females (-7.2 vs. -4.6; p < 0.001). The 5-year estimated explantation-free survival was similar (78.6% vs. 73.7%; p = 0.94) as was the revision-free survival (67.4% vs. 61.7%; p = 0.89). Multivariate analysis showed that female gender was associated with better continence at last follow-up (OR = 4.3; p = 0.03). Conclusion: Robotic female AUS implantation is associated with better functional outcomes than male AUS implantation, with similar morbidity and survival rates.