Jeffrey A. Geller

Dr. Jeffrey A. Geller


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2014 in The Journal of Arthroplasty
Verified
Journal Article
Closed access
ACAbigail L. Campbell
Abigail L. Campbell
DPDavid A. Patrick
David A. Patrick
BLBarthelemy Liabaud
Barthelemy Liabaud
JGJeffrey A. Geller
Jeffrey A. Geller

6 October 2015 in European Journal of Orthopaedic Surgery & Traumatology
Verified
Journal Article
Closed access
PDF file
KMKatherine P. MacCallum
Katherine P. MacCallum
JDJonathan R. Danoff
Jonathan R. Danoff
JGJeffrey A. Geller
Jeffrey A. Geller

20 September 2019 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
EJEugene S. Jang
Eugene S. Jang
RCRonald Connors-Ehlert
Ronald Connors-Ehlert
SLSally LiArno
Sally LiArno
JGJeffrey A. Geller
Jeffrey A. Geller
HCH. John Cooper
H. John Cooper
RSRoshan P. Shah
Roshan P. Shah
Background: Many reference axes are used to evaluate rotation of the femoral component during total knee arthroplasty, including the Whiteside line, surgical transepicondylar axis (sTEA), anatomical transepicondylar axis (aTEA), posterior condylar axis externally rotated 3° (PCA+3°ER), sulcus line, and femoral transverse axis (FTA). There is no consensus about which of these axes is most accurate. Methods: The Stryker Orthopaedic Modeling and Analytics (SOMA) database was used to identify 2,128 entire-femur computed tomography (CT) scans. The Whiteside line, aTEA, PCA+3°ER, sulcus line, and FTA were constructed according to published guidelines. Every axis was compared with the sTEA, which is widely regarded as the gold standard reference axis for rotation of the distal part of the femur but has low intraobserver and interobserver reliability intraoperatively. Results: The PCA+3°ER differed from the sTEA by a mean (and standard deviation) of 0.60° ± 1.64°; it was the most accurate but also had the highest degree of intersubject variability. The mean PCA-sTEA angle was 2.40°, close to the accepted “rule of thumb” of 3°. This value was significantly higher in women (2.64° ± 1.74°) than in men (2.18° ± 1.52°; p < 0.001). The Whiteside line differed from the sTEA by a mean of 1.90° ± 1.38°, and the sulcus line differed from the sTEA by a mean of 1.94° ± 1.49°; neither of these values varied significantly with sex or ethnicity. The FTA differed from the sTEA by a mean of 2.04° ± 1.50°. Least accurate was the aTEA, which differed from the sTEA by a mean of 2.05° ± 1.33°. The combination of 3 axes that are readily available intraoperatively (the Whiteside line, aTEA, and PCA+3°ER) differed from the sTEA by a mean of 1.80° ± 0.70°. Conclusions: In the largest study of its kind, analysis of CT scans of 2,128 femora revealed that no 1 axis could serve as a marker of femoral component rotation with both high accuracy and low variability. Utilizing a combination of 3 methods (PCA+3°ER, the Whiteside or sulcus line, and aTEA) to maximize accuracy and sex and ethnic generalizability when positioning the femoral component is recommended. Clinical Relevance: A large-scale study using a CT-based biomorphometric database demonstrated that use of a combination of 3 axes (PCA+3°ER, the Whiteside or sulcus line, and aTEA) was the optimal strategy for judging femoral component rotation.

18 April 2021 in World Journal of Orthopedics
Verified
Journal Article
Open access
SBScott D Buzin
Scott D Buzin
JGJeffrey A. Geller
Jeffrey A. Geller
RYRichard S. Yoon
Richard S. Yoon
WMWilliam Macaulay
William Macaulay
Lateral unicompartmental knee arthroplasty: A review

12 February 2019 in Knee Surgery, Sports Traumatology, Arthroscopy
Verified
Journal Article
Closed access
PDF file
JWJason Wong
Jason Wong
TMTaylor Murtaugh
Taylor Murtaugh
ALAkshay Lakra
Akshay Lakra
HCH. John Cooper
H. John Cooper
RSRoshan P. Shah
Roshan P. Shah
JGJeffrey A. Geller
Jeffrey A. Geller

16 September 2013 in Autoimmune Diseases
Verified
Journal Article
Open access
PDF file
JDJonathan R. Danoff
Jonathan R. Danoff
GMGarrett Moss
Garrett Moss
BLBarthelemy Liabaud
Barthelemy Liabaud
JGJeffrey A. Geller
Jeffrey A. Geller
The definitive treatment for advanced joint destruction in the late stages of rheumatoid arthritis can be successfully treated with total joint arthroplasty. Total knee arthroplasty has been shown to be a well-proven modality that can provide pain relief and restoration of mobility for those with debilitating knee arthritis. It is important for rheumatologists and orthopedic surgeons alike to share an understanding of the special considerations that must be addressed in this unique population of patients to ensure success in the immediate perioperative and postoperative periods including specific modalities to maximize success.