Shinya Kawahara

Dr. Shinya Kawahara

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 October 2022 in Journal of Bone and Joint Surgery
Verified
Journal Article
Open access
SYSatoshi Yamate
Satoshi Yamate
SHSatoshi Hamai
Satoshi Hamai
SKShinya Kawahara
Shinya Kawahara
DHDaisuke Hara
Daisuke Hara
GMGoro Motomura
Goro Motomura
YNYasuharu Nakashima
Yasuharu Nakashima
Background: Missing responses are common when Asian patients complete the Forgotten Joint Score-12 (FJS-12), which is widely used to evaluate total hip arthroplasty (THA). We aimed to provide orthopaedic researchers with a solution for handling missing values in such patient-reported outcome measures (PROMs). Methods: Patients who had undergone primary THA between 1998 and 2016 (n = 1,021) were investigated in 2020. The FJS-12 and 9 other PROMs, including questions related to Asian lifestyle activities, were administered. Risk factors for missing FJS-12 items were investigated. Partial respondents were matched with complete respondents; then, in each pair, the items not completed by the partial respondent were deleted from the responses of the complete respondent. Predictive mean matching (PMM) was performed in an attempt to recover the deleted items, using 65 sets of imputation models. After the missing values had been imputed, we explored patient characteristics that affected the FJS-12, using data from all complete and partial respondents. Results: A total of 652 patients responded to the survey (393 complete and 193 partial respondents). Partial respondents were older, more often female, and less active. Older respondents were more likely to skip items involving the bed, while those who reported a better ability to sit in the seiza style (traditional Japanese floor sitting) were more likely to skip items about chair sitting. The imputed FJS-12 value exhibited excellent reliability (intraclass correlation coefficient for agreement with the true scores, 0.985). FJS-12 values of complete respondents were significantly higher than those of respondents with 4 to 11 missing items (51.6 versus 32.8, p < 0.001). Older age was associated with higher FJS-12 values, which was revealed only via analysis of the multiply imputed data sets (p < 0.001). Conclusions: Analysis of only complete FJS-12 responses after THA resulted in a nonresponse bias, preferentially excluding older, female, and less active individuals and those with a traditional floor living style. Multiple imputation could provide a solution to scoring and analyzing PROMs with missing responses by permitting the inclusion of partial respondents. Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

4 November 2023 in International Orthopaedics
Verified
Journal Article
Closed access
PDF file
SHSatoru Harada
Satoru Harada
SHSatoshi Hamai
Satoshi Hamai
KSKyohei Shiomoto
Kyohei Shiomoto
SKShinya Kawahara
Shinya Kawahara
DHDaisuke Hara
Daisuke Hara
YNYasuharu Nakashima
Yasuharu Nakashima

1 August 2018 in The Knee
Verified
Journal Article
Closed access
YHYohei Haruta
Yohei Haruta
SKShinya Kawahara
Shinya Kawahara
KTKanenobu Tsuchimochi
Kanenobu Tsuchimochi
AHAkihiko Hamasaki
Akihiko Hamasaki
THToshihiko Hara
Toshihiko Hara

20 July 2024 in Arthroplasty Today
Verified
Journal Article
Open access
TKToshiki Konishi
Toshiki Konishi
TSTaishi Sato
Taishi Sato
SHSatoshi Hamai
Satoshi Hamai
SKShinya Kawahara
Shinya Kawahara
DHDaisuke Hara
Daisuke Hara
YNYasuharu Nakashima
Yasuharu Nakashima
Accurate cup placement in total hip arthroplasty (THA) for patients with dysplasia is challenging due to the distinctive bone deformities. This study aimed to compare the accuracy of cup placement position and orientation across robotic arm–assisted systems (R-THA), computed tomography–based navigation (N-THA), and manual procedure (M-THA) in THA for osteoarthritis secondary to dysplasia. A total of 167 patients (197 hips), including 88 R-THAs, 45 N-THAs, and 46 M-THAs, were analyzed. Propensity score matching was performed to align the patient backgrounds. Horizontal and vertical centers of rotation were measured for cup position, whereas radiographic inclination and anteversion were measured for cup orientation. The proportion of cases with cup placement within 3 mm and 5° from the target was compared. R-THA had a significantly higher percentage of cup placement within 3 mm of the target compared to N-THA (78% vs 49%; P = .0041) and M-THA (78% vs 53%; P = .013). Similarly, R-THA was significantly more successful in placing the cup within 5° of the target compared to N-THA (84% vs 58%; P = .0049) and M-THA (91% vs 20%; P < .0001). Moreover, N-THA was significantly better at placing the cup within 5° of the target compared to M-THA (62% vs 14%; P < .0001), whereas there was no significant difference in the percentage of cup placement within 3 mm of the target (51% vs 51%; P = 1.0). Robotic arm–assisted system and computed tomography–based navigation improved accuracy in cup orientation compared to the manual procedure. Additionally, the robotic arm–assisted system further improved cup position accuracy.

24 February 2021 in Archives of orthopaedic and trauma surgery
Verified
Journal Article
Closed access
PDF file
KKKeisuke Komiyama
Keisuke Komiyama
SHSatoshi Hamai
Satoshi Hamai
GMGoro Motomura
Goro Motomura
SISatoshi Ikemura
Satoshi Ikemura
MFMasanori Fujii
Masanori Fujii
YNYasuharu Nakashima
Yasuharu Nakashima

1 January 2022 in Clinical Biomechanics
Verified
Journal Article
Closed access
SHSatoru Harada
Satoru Harada
SHSatoshi Hamai
Satoshi Hamai
GMGoro Motomura
Goro Motomura
SISatoshi Ikemura
Satoshi Ikemura
MFMasanori Fujii
Masanori Fujii
YNYasuharu Nakashima
Yasuharu Nakashima