Robert Bloom

Mr. Robert Bloom

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2022 in Journal of Neural Engineering
Verified
Journal Article
Closed access
RSRenata Saha
Renata Saha
SFSadegh Faramarzi
Sadegh Faramarzi
RBRobert Bloom
Robert Bloom
OBOnri J Benally
Onri J Benally
Kai WuKai Wu
Kai Wu
JWJian-Ping Wang
Jian-Ping Wang
Objective. The objective of this study was to measure the effect of micromagnetic stimulation ( μ MS) on hippocampal neurons, by using single microcoil ( μ coil) prototype, magnetic pen (MagPen). MagPen will be used to stimulate the CA3 region magnetically and excitatory post synaptic potential (EPSP) response measurements will be made from the CA1 region. The threshold for micromagnetic neurostimulation as a function of stimulation frequency of the current driving the µ coil will be demonstrated. Finally, the optimal stimulation frequency of the current driving the μ coil to minimize power will be estimated. Approach. A biocompatible, watertight, non-corrosive prototype, MagPen was built, and customized such that it is easy to adjust the orientation of the μ coil and its distance over the hippocampal tissue in an in vitro recording setting. Finite element modeling of the μ coil design was performed to estimate the spatial profiles of the magnetic flux density (in T) and the induced electric fields (in V m −1 ). The induced electric field profiles generated at different values of current applied to the µ coil can elicit a neuronal response, which was validated by numerical modeling. The modeling settings for the μ coil were replicated in experiments on rat hippocampal neurons. Main results. The preferred orientation of MagPen over the Schaffer Collateral fibers was demonstrated such that they elicit a neuron response. The recorded EPSPs from CA1 region due to μ MS at CA3 region were validated by applying tetrodotoxin (TTX). Application of TTX to the hippocampal slice blocked the EPSPs from μ MS while after prolonged TTX washout, a partial recovery of the EPSP from μ MS was observed. Finally, it was interpreted through numerical analysis that increasing frequency of the current driving the μ coil, led to a decrease in the current amplitude threshold for micromagnetic neurostimulation. Significance. This work reports that micromagnetic neurostimulation can be used to evoke population EPSP responses in the CA1 region of the hippocampus. It demonstrates the strength-frequency curve for µ MS and its unique features related to orientation dependence of the µ coils, spatial selectivity and stimulation threshold related to distance dependence. Finally, the challenges related to µ MS experiments were studied including ways to overcome them.

10 February 2022 in Nanotechnology
Verified
Journal Article
Closed access
RSRenata Saha
Renata Saha
Kai WuKai Wu
Kai Wu
RBRobert Bloom
Robert Bloom
SLShuang Liang
Shuang Liang
DTDenis Tonini
Denis Tonini
JWJian-Ping Wang
Jian-Ping Wang
In the treatment of neurodegenerative, sensory and cardiovascular diseases, electrical probes and arrays have shown quite a promising success rate. However, despite the outstanding clinical outcomes, their operation is significantly hindered by non-selective control of electric fields. A promising alternative is micromagnetic stimulation ( μ MS) due to the high permeability of magnetic field through biological tissues. The induced electric field from the time-varying magnetic field generated by magnetic neurostimulators is used to remotely stimulate neighboring neurons. Due to the spatial asymmetry of the induced electric field, high spatial selectivity of neurostimulation has been realized. Herein, some popular choices of magnetic neurostimulators such as microcoils ( μ coils) and spintronic nanodevices are reviewed. The neurostimulator features such as power consumption and resolution (aiming at cellular level) are discussed. In addition, the chronic stability and biocompatibility of these implantable neurostimulator are commented in favor of further translation to clinical settings. Furthermore, magnetic nanoparticles (MNPs), as another invaluable neurostimulation material, has emerged in recent years. Thus, in this review we have also included MNPs as a remote neurostimulation solution that overcomes physical limitations of invasive implants. Overall, this review provides peers with the recent development of ultra-low power, cellular-level, spatially selective magnetic neurostimulators of dimensions within micro- to nano-range for treating chronic neurological disorders. At the end of this review, some potential applications of next generation neuro-devices have also been discussed.

31 May 2023 in Journal of Neural Engineering
Verified
Journal Article
Open access
RSRenata Saha
Renata Saha
ZSZachary Sanger
Zachary Sanger
RBRobert Bloom
Robert Bloom
OBOnri J Benally
Onri J Benally
Kai WuKai Wu
Kai Wu
JWJian-Ping Wang
Jian-Ping Wang
Objective. The objective of this study was to investigate the effects of micromagnetic stimuli strength and frequency from the Magnetic Pen (MagPen) on the rat right sciatic nerve. The nerve’s response was measured by recording muscle activity and movement of the right hind limb. Approach. The MagPen was custom-built to be stably held over the sciatic nerve. Rat leg muscle twitches were captured on video, and movements were extracted using image processing algorithms. EMG recordings were also used to measure muscle activity. Main results. The MagPen prototype, when driven by an alternating current, generates a time-varying magnetic field, which, according to Faraday’s law of electromagnetic induction, induces an electric field for neuromodulation. The orientation-dependent spatial contour maps of the induced electric field from the MagPen prototype have been numerically simulated. Furthermore, in this in vivo work on µMS, a dose-response relationship has been reported by experimentally studying how varying the amplitude (Range: 25 mV p-p through 6 V p-p) and frequency (range: 100 Hz through 5 kHz) of the MagPen stimuli alters hind limb movement. The primary highlight of this dose-response relationship (repeated over n rats, where n = 7) is that for a µMS stimuli of higher frequency, significantly smaller amplitudes can trigger hind limb muscle twitch. This frequency-dependent activation can be justified by Faraday’s Law, which states that the magnitude of the induced electric field is directly proportional to the frequency. Significance. This work reports that µMS can successfully activate the sciatic nerve in a dose-dependent manner. The impact of this dose-response curve addresses the controversy in this research community about whether the stimulation from these μcoils arise from a thermal effect or micromagnetic stimulation. MagPen probes do not have a direct electrochemical interface with tissue and therefore do not experience electrode degradation, biofouling, and irreversible redox reactions like traditional direct contact electrodes. Magnetic fields from the μcoils create more precise activation than electrodes because they apply more focused and localized stimulation. Finally, unique features of µMS, such as the orientation dependence, directionality, and spatial specificity, have been discussed.

23 April 2024 in Journal of Vacuum Science & Technology B
Verified
Journal Article
Closed access
PDF file
RSRenata Saha
Renata Saha
OBOnri J. Benally
Onri J. Benally
SFSadegh Faramarzi
Sadegh Faramarzi
RBRobert Bloom
Robert Bloom
Kai WuKai Wu
Kai Wu
JWJian-Ping Wang
Jian-Ping Wang
In the treatment of neurodegenerative disorders, a potential cure at a single neuron cell resolution is still lacking. Micromagnetic neurostimulation, although in its infancy, is one of the most promising techniques that offer spatially selective activation of neurons through micrometer-sized coils or microcoils (μcoils). Time-varying current drives these μcoils and generates a time-varying magnetic field which in turn induces an electric field to activate the neural tissues. In this work, we report the design and fabrication of planar μcoil arrays, termed Magnetic Patch (MagPatch), for activating single neurons. Using numerical calculations on ANSYS-Maxwell and NEURON, we report an optimized MagPatch array design that exploits the directionality of the induced electric field from the μcoils to enhance spatial selectivity. Each μcoil has an outer dimension of 190 × 190 μm2 and one MagPatch array contains 8 μcoils. For proof-of-concept design and development, the MagPatch array has been fabricated on Si-substrates using Ti, Au, and Si3N4 to ensure preliminary biocompatibility. They were then encapsulated in Parylene-C, a waterproof, anti-leakage current coating, thereby ensuring basic surface biocompatibility. Human neuroblastoma cells were cultured directly on the surface encapsulated MagPatch, and calcium fluorescence imaging was used to assess cell functionality. The impact of scaling the dimensions of the μcoil in the MagPatch array on electrical characteristics, Q-factor, and thermal effects on neural tissues from these μcoils have also been discussed.

14 April 2025 in IEEE Transactions on Device and Materials Reliability
Verified
Journal Article
Closed access
YYYong Hyeon Yi
Yong Hyeon Yi
RBRobert Bloom
Robert Bloom
AKArmen Kteyan
Armen Kteyan
AVAlexander Volkov
Alexander Volkov
JCJun-Ho Choy
Jun-Ho Choy
CKChris H. Kim
Chris H. Kim
This work presents silicon data from 28 nm test chips specifically designed to study electromigration (EM) induced lifetime effects. The power grids were generated by an automatic place-and-route tool to create realistic device-under-tests (DUT) to capture power grid EM aging behaviors and lifetimes. Poly-silicon quasi-load cells mimicking the circuit current were employed to withstand high temperature stress. 1,024 local voltages throughout the power grid were tapped out to monitor the voiding locations and IR drop trends with stress. Four power grid architectures with different metal configurations were tested under different temperatures and currents. EM effects under different temperatures and current cycling conditions were also studied.

16 December 2024 in Instruments
Verified
Journal Article
Open access
PDF file
RBRobert Bloom
Robert Bloom
RSRenata Saha
Renata Saha
ZSZachary Sanger
Zachary Sanger
WLWalter C. Low
Walter C. Low
TNTheoden I. Netoff
Theoden I. Netoff
JWJian-Ping Wang
Jian-Ping Wang
Micromagnetic stimulation (μMS) is a promising branch of neurostimulation but without some of the drawbacks of electrical stimulation. Microcoil (μcoil)-based magnetic stimulation uses small micrometer-sized coils that generate a time-varying magnetic field, which, as per Faraday’s Laws of Electromagnetic Induction, induces an electric field on a conductive surface. This method of stimulation has the advantage of not requiring electrical contact with the tissue; however, these μcoils are not easy to operate. Large currents are required to generate the required magnetic field. These large currents are too large for standard test equipment to provide, and additional power amplifiers are needed. To aid in the testing and development of micromagnetic stimulation devices, we have created a compact single-unit test setup for driving these devices called the µCoil Driver. This unit is designed to drive small inductive loads up to ±8 V at 5 A and 10 kHz.