The distributed generation (DG) paradigm has driven the growth of small and medium-scale renewable generation systems located close to demand centers. As a consequence, traditional distribution networks are in a transition towards the so-called Active Distribution Networks (ADNs). However, the intermittent nature of renewable generation causes rapid voltage fluctuations that are difficult to manage and deteriorate power quality. In the literature, the tasks corresponding to the design of voltage control in ADNs are addressed in a heuristic and sequential manner. In this work, a systematic strategy is proposed for the analysis, design and implementation of controllers for voltage regulation in ADNs with DG, based on the Plant Wide Control (PWC) theory of the Process Systems Engineering (PSE) community. This strategy allows us to find control structures that optimize the hardware necessary for its implementation and have good dynamic performance. The general PWC design procedure is formulated as a mixed integer two-level nonlinear programming with cost functions that only depend on the steady state models of the network. To evaluate the proposed methodology, the IEEE 33 distribution network model is used, to which 6 DGs are incorporated. The application of the proposed methodology to identify and evaluate different control structures contributes to the generation of systematic tools to approach the ADN control design process in a comprehensive manner, based on quantitative information.
21 December 2017 in Industrial & Engineering Chemistry Research
In this work the control allocation (CA) philosophy is considered in order to propose a plantwide control (PWC) design methodology. For medium/large-scale processes where the number of actuators is greater than the number of controlled variables, a CA-based strategy can be used to distribute the total control effort among the actuators, with some attractive features. First, the CA module can explicitly handle (i) constraints on inputs (typically actuator position and rate limits), and (ii) additional control objectives (e.g. to penalize the actuators control energy). Second, CA has the potential to provide (actuator) fault tolerance without considering a control structure reconfiguration. In this paper, a decentralized control structure is proposed for computing the total control effort, which is implemented with conventional single-input single-output PID controllers. In addition, a CA module is configured and two alternative algorithms are compared, namely: (i) generalized inverse plus simple saturation, and (ii) active set method for a weighted least-squares formulation. The complete structure can be designed based on steady-state process information. The well-known Tennessee Eastman case study is considered to evaluate the proposal. Several closed-loop simulations are presented to show the dynamic performance of the PWC structure and the timing properties of the CA algorithm.