Simone Buso

Prof. Dr. Simone Buso

orcid

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 1998 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
SBSimone Buso
Simone Buso
LML. Malesani
L. Malesani
PMP. Mattavelli
P. Mattavelli
This paper presents the comparative evaluation of the performance of three state-of-the-art current control techniques for active filters. The linear rotating frame current controller, the fixed-frequency hysteresis controller, and the digital deadbeat controller are considered. The main control innovations, determined by industrial applications, are presented, suitable criteria for the comparison are identified, and the differences in the performance of the three controllers in a typical parallel active filter setup are investigated by simulations.

1 January 2006 in Synthesis Lectures on Power Electronics
Verified
Journal Article
Closed access
SBSimone Buso
Simone Buso
PMPaolo Mattavelli
Paolo Mattavelli
This book presents the reader, whether an electrical engineering student in power electronics or a design engineer, some typical power converter control problems and their basic digital solutions, based on the most widespread digital control techniques. The presentation is focused on different applications of the same power converter topology, the half-bridge voltage source inverter, considered both in its single- and three-phase implementation. This is chosen as the case study because, besides being simple and well known, it allows the discussion of a significant spectrum of the more frequently encountered digital control applications in power electronics, from digital pulse width modulation (DPWM) and space vector modulation (SVM), to inverter output current and voltage control. The book aims to serve two purposes: to give a basic, introductory knowledge of the digital control techniques applied to power converters, and to raise the interest for discrete time control theory, stimulating new dev...

1 September 1998 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
SBSimone Buso
Simone Buso
PMP. Mattavelli
P. Mattavelli
LRL. Rossetto
L. Rossetto
GSG. Spiazzi
G. Spiazzi
This paper presents the practical implementation of a fully digital control for boost power factor preregulators (PFP's). The control algorithm, which is simple and fas$ provides a significant improvement in the system's dynamic performances compared to usual analog control techniques. The paper discusses the design criteria and the actions taken for the implementation of the digital control, which is performed by means of a standard micro-controller (Siemens 80 C166). The effectiveness of the approach is assessed by experimental tests.

25 November 2008 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
VSVladimir V. R. Scarpa
Vladimir V. R. Scarpa
SBSimone Buso
Simone Buso
GSGiorgio Spiazzi
Giorgio Spiazzi
This paper proposes a method for tracking the maximum power point (MPP) of a photovoltaic (PV) module that exploits the relation existing between the values of module voltage and current at the MPP (MPP locus). Experimental evidence shows that this relation tends to be linear in conditions of high solar irradiation. The analysis of the PV module electrical model allows one to justify this result and to derive a linear approximation of the MPP locus. Based on that, an MPP tracking strategy is devised which presents high effectiveness, low complexity, and the inherent possibility to compensate for temperature variations by periodically sensing the module open circuit voltage. The proposed method is particularly suitable for low-cost PV systems and has been successfully tested in a solar-powered 55-W battery charger circuit.

6 December 2019 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
QLQing Liu
Qing Liu
Tommaso CaldognettoTommaso Caldognetto
Tommaso Caldognetto
SBSimone Buso
Simone Buso
Grid-tied inverters are widely used for interfacing renewable energy sources or storage devices to low-voltage electrical power distribution systems. Lately, a number of different control techniques have been proposed to address the emerging requirements of the smart power system scenario, in terms of both functionalities and performance. This paper reviews the techniques proposed for the implementation of current-controlled or voltage-controlled inverters in microgrids. By referring to a voltage source inverter with LCL output filter, the different control architectures are classified as single-, double-, and triple- loop. Then, the functionalities that are needed or recommended in the grid-connected, islanded, and autonomous operating modes of the grid-tied inverter are identified and their implementation in the different control structures is discussed. To validate the analysis and to better illustrate the merits and limitations of the most effective solutions, six control strategies are finally implemented and experimentally compared on a single-phase, grid-connected inverter setup.

1 January 2001 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
SBSimone Buso
Simone Buso
SFS. Fasolo
S. Fasolo
PMP. Mattavelli
P. Mattavelli
A digital control technique for the inverter stage of uninterruptible power supplies (UPSs) is described, which is based on voltage and current predictive regulators. Its aim is to achieve a deadbeat dynamic response for the controlled variables (output voltage and inverter current). The controller maintains the advantageous conventional multiloop structure and is capable of guaranteeing a high-quality dynamic performance. Moreover, its design is extremely simple and requires only a reasonably accurate knowledge of the output filter parameters. Finally, the only sensed variables are the output voltage and the converter output current. The validity of the proposed strategy is demonstrated by means of simulation and experimental results referring to a single-phase UPS laboratory prototype (1 kVA).