In this paper, the authors review the field of parallax error (PE) minimization in positron emission tomography (PET) imaging systems by using depth of interaction (DOI) capable concepts. The review includes apparatus as well as an overview of various methods described in the literature. It also discusses potential advantages gained via these approaches, as discussed with reference to various metrics and tasks, particularly in the improvement of spatial resolution (SR) performance. Furthermore, the authors emphasize limitations encountered in the context of DOI decoding, which can be a considerable pitfall depending on the task of interest.
Charging-up processes affecting gain stability in Thick Gas Electron Multipliers (THGEM) were studied with a dedicated simulation toolkit. Integrated with Garfield++, it provides an effective platform for systematic phenomenological studies of charging-up processes in MPGD detectors. We describe the simulation tool and the fine-tuning of the step-size required for the algorithm convergence, in relation to physical parameters. Simulation results of gain stability over time in THGEM detectors are presented, exploring the role of electrode-thickness and applied voltage on its evolution. The results show that the total amount of irradiated charge through electrode's hole needed for reaching gain stabilization is in the range of tens to hundreds of pC, depending on the detector geometry and operational voltage. These results are in agreement with experimental observations presented previously.
1 March 2017 in Spectrochimica Acta Part B: Atomic Spectroscopy
The calculated position resolutions for X-ray photons (1–60 keV1–60 keV) in pure noble gases at atmospheric pressure are presented. In this work we show the influence of the atomic shells and the detector dimensions on the intrinsic position resolution of the used noble gas. The calculated results were obtained by using a new software tool, Degrad, and compared to the available experimental data
24 October 2014 in Journal of Analytical Atomic Spectrometry
By taking advantage of the attractive features in terms of gain, position and energy resolution of the 2D-THCOBRA detector, a new large area Full-Field X-ray Fluorescence Imaging (FF-XRFI) system for EDXRF imaging applications was developed. The proposed FF-XRFI system has an active area of 10 × 10 cm2 and can be used to examine macroscopic samples with a moderately good energy resolution (<1.6 keV FWHM at 8 keV) and a suitable spatial resolution (∼500 μm FWHM). This combination of characteristics allows us to record elemental distribution maps from the surface of different sample types by combining image and energy information. Two different approaches were used for X-ray optics, one based on a single pinhole and another based on a parallel multiple-hole collimator. To illustrate the system capabilities, some sample examples were imaged and studied.