Yuzhen Wang

Dr. Yuzhen Wang

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 April 2024 in ACS Applied Nano Materials
Verified
Journal Article
Closed access
YCYuying Chen
Yuying Chen
LZLu Zhao
Lu Zhao
MLMeiqing Liu
Meiqing Liu
XCXiaoliang Chen
Xiaoliang Chen
LZLihua Zhang
Lihua Zhang
FFFeng Feng
Feng Feng

1 January 2005
Verified
Book Chapter
Closed access
PDF file
JCJunghuei Chen
Junghuei Chen
RDRussell Deaton
Russell Deaton
MGMax H. Garzon
Max H. Garzon
JKJin Woo Kim
Jin Woo Kim
DWDavid Wood
David Wood
YWYuzhen Wang
Yuzhen Wang

12 September 2017 in RSC Advances
Verified
Journal Article
Open access
PDF file
GKGai-Feng Kang
Gai-Feng Kang
YWYuzhen Wang
Yuzhen Wang
YBYun-Feng Bai
Yun-Feng Bai
ZCZe-Zhong Chen
Ze-Zhong Chen
FFFeng Feng
Feng Feng
In this study, a label-free, specific and sensitive surface plasmon resonance (SPR) based competitive immunoassay was used for detecting Cd2+in water samples.

22 January 2025 in Sensors
Verified
Journal Article
Open access
PDF file
YWYuzhen Wang
Yuzhen Wang
NSNingna Shi
Ningna Shi
KYKang xiao Yue
Kang xiao Yue
QPQiliang Pan
Qiliang Pan
MTMaozhong Tian
Maozhong Tian
YBYunfeng Bai
Yunfeng Bai
A sensitive and specific competitive electrochemical immunosensor for the detection of Hg (II) using a modified electrode based on molybdenum disulfide/reduced graphene oxide/gold (MoS2/rGO/Au) nanocomposites was developed in this study. The nanocomposites were characterized and assembled with an antibody against Hg (II) for the immunosensor, demonstrating good electrical activity, high affinity and high specificity. Free Hg (II) in a solution can be measured by the competitive reaction of the Hg element in the sample and the antigen with the antibody fixed on the electrode. A differential pulse voltammetry (DPV) method was used, and the competitive current changed in accordance with the concentration of Hg (II). Under optimal conditions, the sensor showed a linear relationship from 0.1 to 600 ng/mL, and the limit of detection (LOD) was 63 pg/mL. The proposed immunosensor showed an acceptable recovery from 98.4% to 100.3% in spiked samples. Satisfactory stability and reproducibility were obtained. Competitive species, including Zn (II), Mg (II), Al (III), Cu (II), Pb (II), Ba (II), Cd (II), Ag (I), MNA, CH3Hg (I) and CH3Hg-MNA, were selected and applied according to the procedure of the assay, and their significantly different response compared to Hg (II) indicated that the assay displayed not only high sensitivity but also high selectivity. This immunosensor offers a useful model for the detection of Hg (II).