Background: Intrasaccular flow disruption represents a new paradigm in endovascular treatment of wide-necked bifurcation aneurysms. Objective: To perform a matched case–control study comparing complications and angiographic outcome using the Woven Endobridge (WEB) device and stent-assisted coiling (SAC). Methods: Sixty-six patients treated with the WEB at three German tertiary care centers were included and matched with 66 patients treated with SAC based on aneurysm location and unruptured/ruptured aneurysm status. Parameters were retrospectively analysed and compared between the treatment groups using inverse probability of treatment weighting (IPTW) with propensity scores. Results: Procedural complication rates were 12.1% in the WEB group and 21.2% in the SAC group, which was statistically significant after IPTW adjustment (OR=2.2, 95% CI 1.08 to 4.4, p=0.03). Favourable outcome (modified Rankin scale score ≤2) was achieved by 57/66 (86.4%) in the WEB group and 57/66 (86.4%) in the SAC group (p=1.0). At mid-term follow-up, a similar number of aneurysms achieved adequate occlusion (complete occlusion or neck remnant) in the WEB group (93.9%) and in the SAC group (93.9%, p=1.0). Re-treatment was performed in 10.6% after WEB embolization and 12.1% after SAC (p=1.0). Conclusions: The WEB provides similar mid-term aneurysm occlusion rates to those of SAC, with no additional morbidity and potentially lower complication rates. Long-term outcome analysis will provide a definite conclusion on the use of WEB for intracranial aneurysms.
4 February 2021 in American Journal of Neuroradiology
BACKGROUND AND PURPOSE: Malignant melanoma is an aggressive skin cancer in which brain metastases are common. Our aim was to establish and evaluate a deep learning model for fully automated detection and segmentation of brain metastases in patients with malignant melanoma using clinical routine MR imaging. MATERIALS AND METHODS: Sixty-nine patients with melanoma with a total of 135 brain metastases at initial diagnosis and available multiparametric MR imaging datasets (T1-/T2-weighted, T1-weighted gadolinium contrast-enhanced, FLAIR) were included. A previously established deep learning model architecture (3D convolutional neural network; DeepMedic) simultaneously operating on the aforementioned MR images was trained on a cohort of 55 patients with 103 metastases using 5-fold cross-validation. The efficacy of the deep learning model was evaluated using an independent test set consisting of 14 patients with 32 metastases. Manual segmentations of metastases in a voxelwise manner (T1-weighted gadolinium contrast-enhanced imaging) performed by 2 radiologists in consensus served as the ground truth. RESULTS: After training, the deep learning model detected 28 of 32 brain metastases (mean volume, 1.0 [SD, 2.4] cm3) in the test cohort correctly (sensitivity of 88%), while false-positive findings of 0.71 per scan were observed. Compared with the ground truth, automated segmentations achieved a median Dice similarity coefficient of 0.75. CONCLUSIONS: Deep learning–based automated detection and segmentation of brain metastases in malignant melanoma yields high detection and segmentation accuracy with false-positive findings of <1 per scan.
28 August 2018 in Journal of NeuroInterventional Surgery
Background: Woven Endobridge (WEB) embolization is a safe and efficient technique for endovascular treatment of intracranial aneurysms. However, the management of aneurysm recurrence after WEB placement has not been well described to date. We present our multicenter experience of endovascular retreatment of aneurysm recurrence after WEB implantation. Methods: This is a multicenter study of patients who underwent endovascular retreatment after WEB implantation in three German tertiary care centers. Treatment strategies, complications, and angiographic outcome were retrospectively assessed. Results: Among 122 aneurysms treated with the WEB device, 15 were retreated. Of these, six were initially treated with the WEB only, two were pretreated by coiling, and seven large aneurysms were treated in a multimodality approach. Ten were true aneurysm remnants and five were neck remnants. The reasons for retreatment were WEB migration (n=6), initial incomplete occlusion (n=5), and WEB compression (n=4). Retreatment strategies included coiling (n=4), stent-assisted coiling (n=7), flow diversion (n=3), and placement of an additional WEB (n=1). All procedures were technically successful and there were no procedure-related complications. Among 11 patients available for follow-up after retreatment, three were retreated again. At last angiographic follow-up, available in 11/15 cases at a median of 23 months, complete occlusion was obtained in eight cases and neck remnants in three. Conclusions: This pilot study shows that endovascular retreatment of recurrent or residual aneurysms after WEB implantation can be done safely and can achieve adequate occlusion rates.
24 October 2018 in Journal of NeuroInterventional Surgery
Background The Woven EndoBridge (WEB) device is a novel endovascular tool for the treatment of wide-necked intracranial aneurysms. Objective To evaluate factors influencing aneurysm occlusion and aneurysm recurrence after WEB embolization. Methods A total of 113 patients (mean age 58.9±11.9 years) with 114 aneurysms (mean size 8.6±4.6 mm) were successfully treated with the WEB device at three German tertiary care centers between May 2011 and February 2018. Aneurysm occlusion was evaluated using the Raymond-Roy occlusion classification. We retrospectively collected patient characteristics, anatomical details, and procedural aspects and evaluated their impact on aneurysm occlusion and recurrence. Results Of 98 patients available for a 6-month angiographic follow-up, complete occlusion was achieved in 62.2%, neck remnants in 21.4%, and aneurysm remnants in 16.3%. Aneurysm recurrence occurred in 15.3%. Initial partial aneurysm thrombosis, recurrent aneurysms, aneurysm size, and simultaneous treatment by WEB and coil were associated with aneurysm remnants (p<0.05). Initial partial aneurysm thrombosis, increasing aneurysm size, and treatment by WEB and coil also predicted aneurysm recurrence (p<0.05). In the subgroup analysis of 71 aneurysms treated with WEB only, initial incomplete occlusion and male sex were associated with aneurysm remnants (p<0.05), while aneurysm height correlated with aneurysm recurrence (p=0.008). Conclusions The WEB provides a high rate of adequate occlusion even in a subset of complex wide-necked intracranial aneurysms. Anatomic results tend to be less favourable in large and partially thrombosed aneurysms and after treatment with WEB and coil.
6 August 2018 in Journal of NeuroInterventional Surgery
Background The Derivo Embolization Device (DED) is a novel flow diverter with advanced X-ray visibility, potentially lower thrombogenicity, and an improved delivery system. Objective To evaluate the safety and efficacy of the DED for emergency treatment of ruptured intracranial aneurysms. Methods Between February 2016 and March 2018, 10 patients (median age 54.5 years, seven women) with 11 aneurysms were treated with the DED at three neurovascular centers. Procedural details, complications, morbidity, and aneurysm occlusion (O’Kelly-Marotta scale, OKM) were retrospectively reviewed. Results Among 11 aneurysms treated, there were nine anterior circulation and two posterior circulation aneurysms. Aneurysm morphology was saccular in four cases, dissecting in three, blister-like in three, and fusiform in one. In each case, a single DED was implanted and deployment was technically successful without exception. Adjunctive coiling was performed in two aneurysms. We observed one in-stent thrombosis, presumably due to low response to clopidogrel 4 days after the procedure, which remained with a mild hemiparesis after aspiration thrombectomy. No further thromboembolic or hemorrhagic events occurred. Favorable outcome (modified Rankin scale score ≤2) at last follow-up was achieved in all patients. Among 10 aneurysms available for angiographic follow-up, complete aneurysm occlusion (OKM D) was obtained in nine cases (90.0%). Conclusions In this pilot study, endovascular treatment of ruptured intracranial aneurysms with the DED was feasible and not associated with any incidence of rebleeding. Larger series with longer follow-up are warranted to reach a definite conclusion about this device.
30 May 2018 in Journal of NeuroInterventional Surgery
Background The Derivo Embolization Device (DED) is a novel flow diverter stent that provides increased x-ray visibility, an improved delivery system, and potentially reduced thrombogenicity. The objective of this study was to evaluate the early safety and efficacy of the second-generation DED. Methods We retrospectively analyzed all patients with unruptured intracranial aneurysms (UIAs) treated with the DED between November 2015 and December 2017 in three German tertiary care centers. Procedural details, complications, and morbidity within 30 days after treatment, as well as the aneurysm occlusion rates after 6 months (O’Kelly–Marotta scale, OKM), were evaluated. Results Implantation of the DED was attempted in 42 patients with 42 aneurysms. All procedures were technically successful. Multiple DEDs were used in three aneurysms (7.2%) and adjunctive coiling in 11 (26.2%). Procedure-related complications occurred in four cases (9.5%) including three thromboembolic events and one aneurysm perforation. The morbidity rate was 2.4% and there was no mortality. One patient suffered an ischemic stroke with persistent aphasia at 30-day follow-up due to a thromboembolic infarct (modified Rankin Scale score 1). Among 33 patients (78.6%) available for angiographic follow-up, complete (OKM D) and favorable (OKM C+D) aneurysm occlusion was obtained in 72.7% (24/33) and 87.9% (29/33), respectively. Conclusions Endovascular treatment of UIAs with the DED is associated with high procedural safety and adequate occlusion rates. Examinations at 1- and 2-year follow-up will provide data on the long-term safety and angiographic outcomes of this device.