In this study, oxidative desulfurization of sulfur compounds using hydrogen peroxide, phosphotungstic acid, and phase-transfer agent using high-intensity probe ultrasonication, and high shear mixer was investigated. The effect of agitation speed (7600--14,000 rpm), reaction temperature (50--70°C), and treatment time (10--30 min) on sulfur conversion was examined and optimized using response surface methodology. A box-behnken design was employed to determine the significance of various process parameters and their interactions using analysis of variance. Analytical results for the model sulfur compounds by ultrasound-assisted oxidative desulfurization and high shear showed comparable results. Both treatment systems provided a 98% conversion of dibenzothiopene and benzothiopene to polar sulfones at 70°C in 30 min. In both systems, the experimental data followed the pseudo-first-order equation with activation energy of 60 kJ°mol. Results indicate that ultrasound energy produce greater reaction rates when compared to mixing with no significant difference in activation energy. In addition, the advantages and drawbacks of ultrasound-assisted extraction with respect to the high shear oxidative desulfurization were discussed.
6 March 2012 in Journal of Applied Polymer Science
In this study, Cu(II) removal using non-crosslinked and cross-linked chitosan-coated sand (CCS) from aqueous solution was investigated. To improve the mechanical and chemical stability, chitosan was coated onto sand (CCS) and cross-linked using epichlorohydrin (ECH) and ethylene glycol diglycidyl ether (EGDE). The effect of pH (2.0–5.0) on the adsorption capacity was examined. The maximum adsorption capacity of CCS, CCS–ECH, and CCS–EGDE occurred at an initial pH of 5.0, 4.0, and 5.0, respectively. The kinetic experimental data agreed well with pseudo-second order equation (R2> 0.988), which implies that chemisorption is the rate controlling step. Langmuir, Freundlich and Dubinin–Radushkevich were used to analyze the equilibrium data, where the Langmuir model provided the best fit for the isotherm data obtained using CCS, CCS–ECH, and CCS–EDGE (R2 > 0.990). Adsorption-desorption was carried out using HCl solution (pH 1.0 and 3.0) and tap water (pH 7.0), where HCl solution (pH 1.0) provided the greatest recovery of Cu(II) at 98.3, 87.5 and 83.5% for CCS, CCS–ECH and CCS–EDGE, respectively. The removal of Cu(II) from real groundwater samples were studied, where removal of 57.4, 62.4 and 77.5% were achieved using CCS, CCS–ECH and CCS–EDGE.