Joyoni Dey

Prof. Joyoni Dey

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2020 in Journal of Medical Imaging
Verified
Journal Article
Open access
PDF file
JXJingzhu Xu
Jingzhu Xu
KHKyungmin Ham
Kyungmin Ham
JDJoyoni Dey
Joyoni Dey
According to statistics from the Centers for Disease Control and Prevention, breast cancer is the most common cancer—one in eight American women will develop it sometime during the course of her life. It is the second-highest cause of death among women in the United States. The 5-year relative survival rate of female breast cancer approaches to 90% for cases detected at an early stage, but only to about 22% for stage IV.1 Therefore, screening technologies that can detect breast cancer in the early stage without any signs or symptoms, are necessary for women.

1 April 2023 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
IHI. Hidrovo
I. Hidrovo
JDJoyoni Dey
Joyoni Dey
HMH. Meyer
H. Meyer
DHDaniel Hussey
Daniel Hussey
NKN. N. Klimov
N. N. Klimov
WNW. Newhauser
W. Newhauser
Neutron grating interferometry provides information on phase and small-angle scatter in addition to attenuation. Previously, phase grating moiré interferometers (PGMI) with two or three phase gratings have been developed. These phase-grating systems use the moiré far-field technique to avoid the need for high-aspect absorption gratings used in Talbot–Lau interferometers (TLI) that reduce the neutron flux reaching the detector. We first demonstrate, through theory and simulations, a novel phase grating interferometer system for cold neutrons that requires a single modulated phase grating (MPG) for phase-contrast imaging, as opposed to the two or three phase gratings in previously employed PGMI systems. The theory shows the dual modulation of MPG with a large period and a smaller carrier pitch P, resulting in large fringes at the detector. The theory was compared to the full Sommerfeld–Rayleigh diffraction integral simulator. Then, we proceeded to compare the MPG system to experiments in the literature that use a two-phase-grating-based PGMI with best-case visibility of around 39%. The simulations of the MPG system show improved visibility in comparison to that of the two-phase-grating-based PGMI. An MPG with a modulation period of 300 µm, the pitch of 2 µm, and grating heights with a phase modulation of (π,0, illuminated by a monochromatic beam produces visibility of 94.2% with a comparable source-to-detector distance (SDD) as the two-phase-grating-based PGMI. Phase sensitivity, another important performance metric of the grating interferometer, was compared to values available in the literature, viz. the conventional TLI with the phase sensitivity of 4.5 × 103 for an SDD of 3.5 m and a beam wavelength of 0.44 nm. For a range of modulation periods, the MPG system provides comparable or greater theoretical maximum phase sensitivity of 4.1 × 103 to 10.0 × 103 for SDDs of up to 3.5 m. This proposed MPG system appears capable of providing high-performance PGMI that obviates the need for the alignment of two phase gratings.

1 June 2017 in Quantitative Imaging in Medicine and Surgery
Verified
Journal Article
Closed access
PDF file
IHIvan Hidrovo
Ivan Hidrovo
JDJoyoni Dey
Joyoni Dey
MCMegan E. Chesal
Megan E. Chesal
DSDmytro Shumilov
Dmytro Shumilov
NBNarayan Bhusal
Narayan Bhusal
JMJ. Michael Mathis
J. Michael Mathis
Background: Over the last decade, several theoretical tumor-models have been developed to describe tumor growth. Oncology imaging is performed using various modalities including computed tomography (CT), magnetic resonance imaging (MRI), single-photon emission computed tomography (SPECT) and fluorodeoxyglucose-positron emission tomography (FDG-PET). Our goal is to extract useful, otherwise hidden, quantitative biophysical parameters (such as growth-rate, tumor-necrotic-factor, etc.) from these serial images of tumors by fitting mathematical models to images. These biophysical features are intrinsic to the tumor types and specific to the study-subject, and expected to add valuable information on the tumor containment or spread and help treatment plans. Thus, fitting realistic but practical models and assessing parameter-errors and degree of fit is important. Methods: We implemented an existing theoretical ode-compartment model and variants and applied them for the first time, in vivo. We developed an inversion algorithm to fit the models for tumor growth for simulated as well as in vivo experimental data. Serial SPECT/CT scans of mice breast-tumors were acquired, and SPECT data was used to segment the proliferating-layers of tumors. Results: Results of noisy data simulation and inversion show that 5 out of 7 parameters were recovered to within 4.3% error. In particular, tumor “growth-rate” parameter was recovered to 0.07% error. For model fitting to in vivo mice-tumors, regression analysis on the P-layer volume showed R2 of 0.99 for logistic and Gompertzian while surface area model yielded R2=0.96. For the necrotic layer the R2 values were 0.95, 0.93 and 0.94 respectively for surface-area, logistic and Gompertzian. The Akaike Information Criterion (AIC) weights of the models (giving their relative probability of being the best Kullback-Leibler (K-L) model among the set of candidate models) were ~0, 0.43 and 0.57 for surface-area, logistic and Gompertzian models. Conclusions: Model-fitting to mice tumor studies demonstrates feasibility of applying the models to in vivo imaging data to extract features. Akaike information criterion (AIC) evaluations show Gompertzian or logistic growth model fits in vivo breast-tumors better than surface-area based growth model.

5 November 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
HMHunter Meyer
Hunter Meyer
JDJoyoni Dey
Joyoni Dey
SCSydney Carr
Sydney Carr
KHKyungmin Ham
Kyungmin Ham
LBLeslie G. Butler
Leslie G. Butler
KKKonradin Kaiser
Konradin Kaiser
X-ray grating interferometry allows for the simultaneous acquisition of attenuation, differential-phase contrast, and dark-field images, resulting from X-ray attenuation, refraction, and small-angle scattering, respectively. The modulated phase grating (MPG) interferometer is a recently developed grating interferometry system capable of generating a directly resolvable interference pattern using a relatively large period grating envelope function that is sampled at a pitch that is small enough that X-ray spatial coherence can be achieved by using a microfocus X-ray source or G0 grating. We present the theory of the MPG interferometry system for a 2-dimensional staggered grating, derived using Fourier optics, and we compare the theoretical predictions with experiments we have performed with a microfocus X-ray system at Pennington Biomedical Research Center, LSU. The theoretical and experimental fringe visibility is evaluated as a function of grating-to-detector distance. Additionally, quantitative experiments are performed with porous carbon and alumina compounds, and the mean normalized dark-field signal is compared with independent porosimetry measurements. Qualitative analysis of attenuation and dark-field images of a dried anchovy are shown.

8 November 2018 in Medical Physics
Verified
Journal Article
Closed access
PDF file
NBNarayan Bhusal
Narayan Bhusal
JDJoyoni Dey
Joyoni Dey
JXJingzhu Xu
Jingzhu Xu
KKKesava Kalluri
Kesava Kalluri
AKArda Konik
Arda Konik
PPP. Hendrik Pretorius
P. Hendrik Pretorius

4 April 2022
Verified
Conference Paper
Open access
EPElizabeth Park
Elizabeth Park
JXJingzhu Xu
Jingzhu Xu
JDJoyoni Dey
Joyoni Dey
SPIE Digital Library Proceedings