Amit Badhwar

Dr. Amit Badhwar

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 April 2023 in Frontiers in Surgery
Verified
Journal Article
Open access
CDCorey R. Deeken
Corey R. Deeken
DCDavid C. Chen
David C. Chen
MLManuel Lopez-Cano
Manuel Lopez-Cano
DMDavid P. Martin
David P. Martin
ABAmit Badhwar
Amit Badhwar
Background: Poly-4-hydroxybutyrate (P4HB) is a fully resorbable, biologically-produced polymer with a strength and flexibility comparable to permanent synthetic polymers. The objective was to identify/summarize all peer-reviewed publications involving P4HB mesh.Methods: A scoping review was conducted within PubMed and included articles published through October 2022.Results: A total of n = 79 studies were identified (n = 12 in vitro/bench; n = 14 preclinical; n = 6 commentaries; n = 50 clinical). Of the clinical studies, n = 40 reported results applicable to hernia and n = 10 to plastic/reconstructive surgery and involved patients of all Centers for Disease Control (CDC) wound classes and Ventral Hernia Working Group (VHWG) grades.Conclusion: P4HB mesh provides long-term hernia repair strength and exhibits promising clinical outcomes beyond its resorption period. Future studies should include randomized controlled trials comparing P4HB to other biomaterials, as well as optimal patient selection, operative technique, long-term outcomes, minimization of potential mesh-related complications, and potential contraindications/complications for P4HB in hernia/abdominal wall reconstruction.

1 October 2019 in Annals of Medicine & Surgery
Verified
Journal Article
Open access
SLSpencer P. Lake
Spencer P. Lake
NSNathaniel F.N. Stoikes
Nathaniel F.N. Stoikes
ABAmit Badhwar
Amit Badhwar
CDCorey R. Deeken
Corey R. Deeken
Hybrid hernia meshes combine biological tissue-derived extracellular matrix with permanent or resorbable synthetic. The objective of this study was to evaluate hybrid meshes (Gore® Synecor, Zenapro™, Ovitex™ 1S Reinforced Bioscaffold Permanent, and Ovitex™ 1S Reinforced Bioscaffold Resorbable) compared to non-hybrid, bioresorbable synthetic mesh (Phasix™ Mesh) in a rabbit bacterial inoculation model. Subcutaneous pockets were bilaterally created in male, New Zealand White rabbits (n = 25). Circular meshes (3.8 cm diameter) were implanted and inoculated with 1 × 106 colony forming units (CFU) of clinically-isolated methicillin-resistant Staphylococcus aureus (MRSA). A given animal received a single mesh type. Seven days post-inoculation, animals were euthanized and white material and microbial colonization were assessed by abscess scoring and CFU quantification, respectively. Non-parametric Kruskal-Wallis with Dunn's post-hoc tests compared results for different meshes. Phasix™ Mesh and Synecor exhibited significantly lower abscess scores than Zenapro™, Ovitex™ 1S Permanent, and Ovitex™ 1S Resorbable (p < 0.05). All pocket swabs for Zenapro™ and Ovitex™ meshes were positive for MRSA (100%), with 20% of Synecor and 0% Phasix™ Mesh. Microbial colonization was significantly lower for Phasix™ Mesh (0 CFU) relative to Zenapro™ (6.73 × 107 CFU (median)), Ovitex™ 1S Permanent (7.87 × 107 CFU) and Ovitex™ 1S Resorbable (1.45 × 108 CFU), and for Synecor (0 CFU) relative to both Ovitex™ meshes. Phasix™ Mesh was the only device with no detectable abscess or microbial colonization. Phasix™ Mesh demonstrated no detectable abscess or microbial colonization at 7-days post-implantation and inoculation, in contrast with four hybrid meshes, which all demonstrated colonization in a rabbit bacterial inoculation model.

10 October 2023 in Frontiers in Surgery
Verified
Journal Article
Open access
CDCorey R. Deeken
Corey R. Deeken
MRMichael J. Rosen
Michael J. Rosen
BPBenjamin K. Poulose
Benjamin K. Poulose
KBKasia Bradbury
Kasia Bradbury
LHLi-Ching Huang
Li-Ching Huang
ABAmit Badhwar
Amit Badhwar
Background: Permanent synthetic meshes such as polypropylene (PP) have been utilized for hernia repair for decades, but concerns remain regarding potential long-term, mesh-related complications. A resorbable polymer such as poly-4-hydroxybutyrate (P4HB) represents an alternative with high initial strength, that gradually resorbs, leaving an abdominal wall that is at least as strong as it would be in its native state. We aimed to compare early wound morbidity and clinical outcomes associated with P4HB to traditional, permanent PP in umbilical and small to medium, routine ventral hernias using data from the Abdominal Core Health Quality Collaborative (ACHQC).Methods: Inclusion criteria for the umbilical cohort included: all Centers for Disease Control and Prevention (CDC) wound classes, all Ventral Hernia Working Group (VHWG) hernia grades, and hernia defects <3 cm. The small to medium, routine ventral hernia cohort was limited to CDC class I wounds, VHWG hernia grades I and II, and hernia defects <5 cm. The study group was comprised of P4HB meshes; the comparator group was an aggregate of PP meshes. Clinical outcomes were assessed at 30 days.Results: There was no significant difference in early wound morbidity, readmission, or reoperation between the P4HB and PP cohorts. A small number of patients experienced SSO, with ≤4% requiring procedural intervention. None of the patients (0% in all cases) experienced skin/soft tissue necrosis, infected seroma, infected hematoma, exposed/contaminated/infected mesh, enterocutaneous fistula, graft failure, or pain requiring intervention at 30-days. However, P4HB was associated with significantly greater operative time, length of stay, and use of myofascial release compared to PP (p < 0.05 in all cases).Conclusions: Short-term clinical outcomes associated with resorbable P4HB mesh are comparable to permanent synthetic PP mesh in umbilical and small to medium, routine ventral hernia repairs, despite significant differences in operative time and length of stay. Longer-term follow-up is needed to expand on the clinical relevance of these short-term findings.

1 June 2023 in Medical Devices: Evidence and Research
Verified
Journal Article
Open access
PDF file
SLSpencer P Lake
Spencer P Lake
KBKasia Bradbury
Kasia Bradbury
DGDarcy H Gagne
Darcy H Gagne
CDCorey R Deeken
Corey R Deeken
ABAmit Badhwar
Amit Badhwar
ABAngela Bohnen
Angela Bohnen
Introduction: Excessive bleeding in trauma and surgical settings leads to increased operative time, reoperation rates, and overall healthcare costs. A wide range of hemostatic agents have been developed to control bleeding that can vary considerably in type of hemostatic action, ease of application, cost, risk of infection, and dependence on patient coagulation. Microfibrillar collagen-based hemostatic materials (MCH) have yielded beneficial results in a variety of applications. Methods: A new flowable collagen product, containing a modified MCH flour, but in a more convenient flowable delivery system, was evaluated for hemostatic efficacy in preclinical models of solid organ injury and spinal cord exposure. The primary objective of this study was to compare the hemostatic potential and local tissue responses to this novel, flowable collagen-based hemostatic agent to the original flour formulation to confirm that the new method of delivery did not interfere with the hemostatic properties of the MCH flour. Results: When observed visually, the flowable MCH flour mixed with saline (FL) provided more precise application and uniform coverage to injured tissues compared to the dry MCH flour alone (F0). All of the treatments (FL, F0, and gauze) exhibited comparable Lewis bleed grade at all three time points evaluated in the capsular resection liver injury model (bleed grade: 1.0– 1.3; p> 0.05 in all cases). FL and F0 exhibited comparable 100% acute hemostatic efficacy and similar long-term histomorphological properties (up to 120 days) in a capsular resection liver injury in pigs, while gauze resulted in significantly lower rates of acute hemostatic efficacy (8– 42%, p< 0.05 in all cases). In an ovine model of dorsal laminectomy and durotomy, FL and F0 again exhibited comparable results without any neurological effects. Conclusion: Flowable microfibrillar collagen was shown to yield favorable short- and long-term outcomes in two representative applications where hemostatic efficacy is critical to surgical success.

12 October 2020 in Journal of Investigative Surgery
Verified
Journal Article
Open access
CDCorey R. Deeken
Corey R. Deeken
DGDarcy H. Gagne
Darcy H. Gagne
ABAmit Badhwar
Amit Badhwar
The objective of this study was to determine mechanical and histological properties of Phasix™ ST Mesh in various defect sizes and characterize the tissue replacing Phasix™ ST Mesh in a porcine mod...

11 February 2025 in Surgeries
Verified
Journal Article
Open access
PDF file
DGDarcy Helga Gagne
Darcy Helga Gagne
CSCatherine C. Steele
Catherine C. Steele
JKJohn Keating
John Keating
KBKasia Bradbury
Kasia Bradbury
ABAmit Badhwar
Amit Badhwar
SESakib Elahi
Sakib Elahi
Background/Objectives: The porcine mammary anatomy is poorly characterized, and structures are difficult to differentiate macroscopically, unlike human mammary tissue. The objective of this exploratory study was to describe the Yucatan porcine breast tissue morphology and identify the basic differences and similarities to human breast tissue. Methods: Samples from an adult, non-parous female Yucatan pig were prepared utilizing various methods: freezing at −80 °F (−26.67 °C) with a thickness of 0.5 cm/post-fixation in formalin; freezing at −20 °F (−6.67 °C) with a thickness of 0.5 cm/post-fixation in formalin; or formalin fixed and incised at ~0.8 cm. A descriptive comparison of the gross and microscopic images of the porcine breast morphology to the previously described human breast anatomy was performed. Results: As examined grossly, frozen sections allowed narrower serial cross-sectioning and better visualization of the structures and relationships. The mammary glands were poorly demarcated with extensive interspersed adipose tissue throughout the periphery. The mammary tissue appeared grossly as pigmented tissue and extended within ~0.5 cm from the skin surface, ~2.0 cm deep (within ~0.5 cm of the deep muscle layer), and ~6.5 cm laterally (centered on a teat). There were a number of similarities between Yucatan porcine and human breast tissue, yet there were several inherent structural differences. In contrast to human mammary tissue, porcine mammary glands consist of more diffuse acinar tissue, less well demarcated by defined fascial, lamellar, and ligamentous structures. Conclusions: The Yucatan porcine mammary morphology and similarities to the human mammary region allow for the use of this animal model to guide those developing relevant technologies or performing local surgical interventions in the preclinical setting.