Finite element models of electrical machines allow insights in electrothermal stresses which endanger the insulation system of the machine. This paper presents a thermal finite element model of a 3.7 kW squirrel-cage induction machine. The model resolves the conductors and the surrounding insulation materials in the stator slots. A set of transient thermal scenarios is defined and measured in the machine laboratory. These data are used to assess the finite element model.
The demand for higher power density in electrical machines necessitates advanced cooling strategies. Spray cooling emerges as a promising and relatively straightforward technology, albeit involving complex physics. In this paper, a quasi-3D thermal finite-element model of stator winding is created by the extrusion of a 2D cross-sectional finite-element model along the winding direction. The cooling effects of the spray impact are simulated as a heat flux that uses an impedance boundary condition at the surface of the winding overhang. The results confirm the advantageous performance of spray cooling, indicating that it may enable a tenfold increase in power density compared to standard air- or water-cooled machines.
Finite element models of electrical machines allow insights in electrothermal stresses which endanger the insulation system of the machine. This paper presents a thermal finite element model of a 3.7 kW squirrel-cage induction machine. The model resolves the conductors and the surrounding insulation materials in the stator slots. A set of transient thermal scenarios is defined and measured in the machine laboratory. These data are used to assess the finite element model.