There exists a high level of difficulty in understanding the physical responses of complex dynamical systems. To this end, researchers have previously used different measurement techniques, such as displacement sensors or accelerometers, in the laboratory to capture a system’s dynamics. A well-known structure in the literature is the Box Assembly with Removable Component (BARC) whose purpose is to gain a deep understanding of testing complex systems. Further breaking down the structure, the Removable Component (RC) portion is often used as a relatively simplified version which retains significant complexity from the original system. However, the placement of accelerometers on the RC have varied greatly throughout the literature which presents a challenge in comparing results and may not accurately represent the system’s dynamics. Finite Element Analysis (FEA) is performed for three common accelerometer locations to determine how their placement affects the frequencies and mode shapes for the RC and results are compared against those without accelerometers. Free vibration experiments are carried out to understand the variation of frequencies and damping for each accelerometer location to obtain the overall response for the first mode of vibration. Next, random vibration experiments are run to gain insight on the interaction between linear and nonlinear responses based on excitation level, while showing the influence of an accelerometer’s location on system dynamics. The results demonstrate that the location of the accelerometer is highly influential on the linear and nonlinear characteristics of the system. It is proved that for the first mode of vibration, nonlinear softening and nonlinear damping behaviors may take place due to the interaction between the location of accelerometers, direction of excitation, and response axis analyzed.
An investigation into the Box Assembly with Removable Component (BARC) structure is conducted by utilizing computational simulations and experimental structural testing in order to determine the complex dynamical responses instigated by the central cut of the system. Because the dynamics of the BARC system is complex, this study focuses primarily on analyzing the behavior of the box assembly (BA) system. The investigation explores the dynamics of the BA system by varying the central cut widths, ranging from a cut as wide as 0.5” cut to a 0.25” cut system, as well as a 0.1” cut and a system with no cut at all. Experimental testing is performed on each system including a free vibration test using an impact hammer to excite and identify the dominant frequencies of each structure. This testing is followed by pseudo-random vibration tests and swept sinusoidal excitation tests to determine the nonlinear aspects of these systems, such as the possible existence of nonlinear softening, hardening, and/or damping. The results show that nonlinear softening and nonlinear damping are present in each system. The no-cut system demonstrated the highest peak frequencies throughout all the tests, being the most rigid structure. The 0.25” cut system was shown to have the highest peak frequencies among all the cut systems in both the finite elemenet analysis (FEA) and impact testing. This trend did not continue, though, in the random and harmonic testing, possibly due to the added stiffness of the test setup with the slip table and stinger. The results show the importance of accurately measuring the central cut width and how possible geometric uncertainties change the overall dynamical behaviors of complex systems, such as natural characteristics, nonlinear responses, coupling of modes, and oscillating amplitudes.
This investigation focuses on the dynamical effects caused by varying the central-cut width within the Box Assembly with Removable Component (BARC) system. The central-cut widths included in this study are a 0.5″ cut, a 0.25″ cut, a thin 0.1″ cut, and a structure that did not have a cut at all. Finite element analysis was conducted to determine the mode shapes and natural frequencies of each of the BARC structures. Structural dynamics experiments were run to examine the effects of the central-cut width on the dynamical responses and nonlinear characteristics of the BARC system. Free vibration testing with an impact hammer was carried out to excite the system and extract the dominant frequencies and directions of the significant responses. A pseudorandom vibration test that allows for the qualitative determination of any nonlinear behavior within the system was performed. This type of behavior can include nonlinear softening, nonlinear hardening, and the most common, nonlinear damping due to the presence of several bolted-joint connections and the possible activation of geometric and inertia nonlinearities. To quantitatively investigate the impacts of the central-cut width on the dynamics of the system, swept sinusoidal testing was conducted. It is determined that almost all systems with central cuts demonstrate the presence of nonlinear softening, but at times, nonlinear hardening trends are seen, particularly in the 0.1″ cut and no-cut systems when testing harmonically. Each of the central-cut systems displays nonlinear damping, with the amount of damping generally increasing as the central cut decreases in size. The effect of the central cut of the BARC system on the mode-switching ability of the system is negligible; however, mode switching takes place when comparing the central-cut configurations to the no-cut one. These results show the significance of accurately measuring the central-cut width and how geometric uncertainty may change the dynamical responses and nonlinear properties of the system.
Scalability of the original test design for the box assembly with removable component (BARC) structure is of interest in the field of experimental structural analysis. As complex structures become increasingly difficult to test experimentally the larger they become, it is a common test practice to use a scaled-down representative model to understand the characteristics of these systems. For complex structures with non-rigid boundary conditions, there exists a gap in understanding the effects of scalability and welding. To gain a better understanding of the outcomes of this phenomenon, the dynamical effects of upscaling the dimensions of the BARC structure are analyzed. Three variations of the BARC are investigated experimentally and computationally, namely, the original BARC system, the BARC system upscaled at 1.5 times the size of the original model, and the BARC system upscaled at two times the size of the original model. The original BARC is tested to investigate the properties of the predetermined boundary conditions. Because the upscaled BARC systems are manufactured using welding, an investigation of the variability of results due to welding imperfections is conducted to evaluate its effects on the vibrational properties of the systems. The dominant resonant frequencies of the three systems are identified through an impact hammer test. The results are then compared to those obtained through finite element analysis, in which both datasets show agreement. In general, as the BARC system is upscaled, the resonant frequencies decrease without inducing mode switching for the selected boundary conditions, indicating that the larger systems are less rigid. To understand the trends of nonlinear softening/hardening and nonlinear damping, forced vibration experiments conducted in the form of true random and controlled stepped-sine excitations are performed. The results show that, in general, as the BARC system is upscaled, changes in the nonlinear properties of the system are induced. With regard to the effects of using welding to manufacture BARC systems, the results prove that variations in welding can lead to non-negligible variations in the vibratory responses of the BARC system. Additionally, several types of harmonic vibrational testing are investigated to understand the physics behind their varied responses. Overall, this work shows that upscaling the BARC system can be beneficial to researchers who require a less rigid system for investigations and that manufacturing of BARC systems by welding can be a cost-effective alternative to subtractive manufacturing.