Edward Mallen

Dr. Edward Mallen


Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2002 in British Journal of Ophthalmology
Verified
Journal Article
Open access
PDF file
JSJ Santodomingo-Rubido
J Santodomingo-Rubido
EMEdward Mallen
Edward Mallen
BGB Gilmartin
B Gilmartin
James S. WolffsohnJames S. Wolffsohn
James S. Wolffsohn
Background: A new commercially available device (IOLMaster, Zeiss Instruments) provides high resolution non-contact measurements of axial length (using partial coherent interferometry), anterior chamber depth, and corneal radius (using image analysis). The study evaluates the validity and repeatability of these measurements and compares the findings with those obtained from instrumentation currently used in clinical practice. Method: Measurements were taken on 52 subjects (104 eyes) aged 18–40 years with a range of mean spherical refractive error from +7.0 D to −9.50 D. IOLMaster measurements of anterior chamber depth and axial length were compared with A-scan applanation ultrasonography (Storz Omega) and those for corneal radius with a Javal-Schiötz keratometer (Topcon) and an EyeSys corneal videokeratoscope. Results: Axial length: the difference between IOLMaster and ultrasound measures was insignificant (0.02 (SD 0.32) mm, p = 0.47) with no bias across the range sampled (22.40–27.99 mm). Anterior chamber depth: significantly shorter depths than ultrasound were found with the IOLMaster (−0.06 (0.25) mm, p <0.02) with no bias across the range sampled (2.85–4.40 mm). Corneal radius: IOLMaster measurements matched more closely those of the keratometer than those of the videokeratoscope (mean difference −0.03 v −0.06 mm respectively), but were more variable (95% confidence 0.13 v 0.07 mm). The repeatability of all the above IOLMaster biometric measures was found to be of a high order with no significant bias across the measurement ranges sampled. Conclusions: The validity and repeatability of measurements provided by the IOLMaster will augment future studies in ocular biometry.

1 April 2003 in Optometry and Vision Science
Verified
Journal Article
Closed access
LDLeon Nicholas Davies
Leon Nicholas Davies
EMEdward Mallen
Edward Mallen
James S. WolffsohnJames S. Wolffsohn
James S. Wolffsohn
BGBernard Gilmartin
Bernard Gilmartin

1 March 2006 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Closed access
PDF file
EMEdward Mallen
Edward Mallen
PKPriti Kashyap
Priti Kashyap
KHKaren M. Hampson
Karen M. Hampson
Purpose. To measure the degree of transient axial elongation during the accommodation response in emmetropic and myopic young adults. To evaluate the effect of refractive error and accommodative demand on transient axial elongation of the eye. methods. Axial length of the right eye was measured in 30 emmetropes and 30 myopes, by using the IOLMaster (Carl Zeiss Meditec, Inc., Dublin, CA), while accommodative stimuli of 0, 2, 4 and 6 D were presented with a Badal optometer. results. Axial length increased in both emmetropic and myopic subjects during short periods of accommodative stimulation. Greater transient increases in axial length were observed in myopic than in emmetropic subjects. The mean axial elongation with a 6-D stimulus to accommodation was 0.037 mm in emmetropes and 0.058 mm in myopes (P = 0.02). The degree of transient axial elongation correlated well with the stimulus to accommodation in emmetropes and myopes. Anterior chamber depth decreased, on average, by 0.19 mm in emmetropes and 0.18 mm in myopes when observing a 6-D stimulus to accommodation. conclusions. During relatively short periods of accommodative stimulation, axial length increases in both emmetropic and myopic young adults. At higher levels of accommodative stimulation, a significantly greater transient increase in axial length is observed in myopic subjects than in their emmetropic counterparts.

9 April 2012 in Ophthalmic and Physiological Optics
Verified
Journal Article
Closed access
PDF file
PVPavan K Verkicharla
Pavan K Verkicharla
AMAnkit Mathur
Ankit Mathur
EMEdward Mallen
Edward Mallen
JPJames M Pope
James M Pope
DADavid A Atchison
David A Atchison

14 February 2006 in Acta Ophthalmologica Scandinavica
Verified
Journal Article
Closed access
LDLeon N. Davies
Leon N. Davies
HBHannah Bartlett
Hannah Bartlett
EMEdward Mallen
Edward Mallen
James S. WolffsohnJames S. Wolffsohn
James S. Wolffsohn

9 June 2005 in Ophthalmic and Physiological Optics
Verified
Journal Article
Closed access
PDF file
EMEdward Mallen
Edward Mallen
YGYazan Gammoh
Yazan Gammoh
MBMuawyah Dawoud Al Bdour
Muawyah Dawoud Al Bdour
FSFouad N. Sayegh
Fouad N. Sayegh