Yung-Sung Lee

Dr. Yung-Sung Lee

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2017 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
PDF file
HCHenry Shen-Lih Chen
Henry Shen-Lih Chen
CLChun-Hsiu Liu
Chun-Hsiu Liu
WWWei-Chi Wu
Wei-Chi Wu
HTHsiao-Jung Tseng
Hsiao-Jung Tseng
YLYung-Sung Lee
Yung-Sung Lee
Purpose: To quantitatively evaluate the superficial microvasculature in the macular and peripapillary areas in glaucomatous and healthy eyes using optical coherence tomography angiography (OCT-A). Methods: We enrolled 26 eyes of medically managed primary open-angle glaucoma patients and 27 eyes of healthy subjects were enrolled in this prospective study. Measurements of OCT-A vessel density were acquired both in the macular and peripapillary areas. We compared vessel density values, the circumpapillary retinal nerve fiber layer (cpRNFL), the ganglion cell complex (GCC), and standard automated perimetry (SAP) parameters across study groups. Areas under the receiver operating characteristic (AUROC) curves were used to evaluate diagnostic accuracy. Quadratic regression models were used to determine the correlations between SAP severity and outcome measures. Results: The whole image vessel density (wiVD) in glaucomatous eyes was lower than that in healthy eyes in the macular (38.5% ± 2.2% vs. 43.2% ± 2.3%, P < 0.001) and peripapillary areas (43.8% ± 5.7% vs. 53.3% ± 3.0%, P < 0.001). The circumpapillary vessel density (cpVD) was also lower in glaucomatous eyes (53.3% ± 7.0% vs. 61.5% ± 3.2%, P < 0.001). We found the AUROCs for discriminating between glaucomatous and healthy eyes were highest for cpRNFL (0.95) and GCC (0.95); followed by macular wiVD (0.94); peripapillary wiVD (0.93); and cpVD (0.89). The correlations between SAP severity were strongest with peripapillary wiVD (R2 = 0.58); followed by cpVD (R2 = 0.55); GCC (R2 = 0.51); cpRNFL (R2 = 0.42); and macular wiVD (R2 = 0.36). Conclusions: Medically managed glaucomatous eyes show sparser superficial microvasculature in the macular area than do healthy eyes. The measurement of the macular superficial vessel density had similar diagnostic accuracy to peripapillary RNFL and macular GCC thickness for differentiating between glaucomatous and healthy eyes.

10 February 2025 in Biomedicines
Verified
Journal Article
Open access
PDF file
XLXiao Chun Ling
Xiao Chun Ling
HCHenry Shen-Lih Chen
Henry Shen-Lih Chen
PYPo-Han Yeh
Po-Han Yeh
YCYu-Chun Cheng
Yu-Chun Cheng
CHChu-Yen Huang
Chu-Yen Huang
YLYung-Sung Lee
Yung-Sung Lee
Purpose: To evaluate the performance of deep learning (DL) in diagnosing glaucoma and predicting its progression using fundus photography and retinal optical coherence tomography (OCT) images. Materials and Methods: Relevant studies published up to 30 October 2024 were retrieved from PubMed, Medline, EMBASE, Cochrane Library, Web of Science, and ClinicalKey. A bivariate random-effects model was employed to calculate pooled sensitivity, specificity, positive and negative likelihood ratios, and area under the receiver operating characteristic curve (AUROC). Results: A total of 48 studies were included in the meta-analysis. DL algorithms demonstrated high diagnostic performance in glaucoma detection using fundus photography and OCT images. For fundus photography, the pooled sensitivity and specificity were 0.92 (95% CI: 0.89–0.94) and 0.93 (95% CI: 0.90–0.95), respectively, with an AUROC of 0.90 (95% CI: 0.88–0.92). For the OCT imaging, the pooled sensitivity and specificity were 0.90 (95% CI: 0.84–0.94) and 0.87 (95% CI: 0.81–0.91), respectively, with an AUROC of 0.86 (95% CI: 0.83–0.90). In predicting glaucoma progression, DL models generally showed less robust performance, with pooled sensitivities and specificities ranging lower than in diagnostic tasks. Internal validation datasets showed higher accuracy than external validation datasets. Conclusions: DL algorithms achieve excellent performance in diagnosing glaucoma using fundus photography and OCT imaging. To enhance the prediction of glaucoma progression, future DL models should integrate multimodal data, including functional assessments, such as visual field measurements, and undergo extensive validation in real-world clinical settings.

22 September 2022 in Journal of Personalized Medicine
Verified
Journal Article
Open access
PDF file
YCYEN-TING CHEN
YEN-TING CHEN
PYPo-Han Yeh
Po-Han Yeh
YCYu-Chun Cheng
Yu-Chun Cheng
WSWei-Wen Su
Wei-Wen Su
YHYih-Shiou Hwang
Yih-Shiou Hwang
SSSu-Chin Shen
Su-Chin Shen
Purpose: To report the application of LUXIE and validate its reliability by comparing the test results with those of Humphrey Field Analyzer 3 (HFA3). Methods: In this pilot study, we prospectively recruited participants who had received HFA3 SITA standard 30-2 perimetry and tested them with LUXIE on the same day. LUXIE is a software designed for visual field testing cooperating with HTC Vive Pro Eye, a head-mounted virtual reality device with an eye-tracking system. The test stimuli were synchronized with eye movements captured by the eye-tracking system to eliminate fixation loss. The global, hemifields, quadrants, glaucoma hemifield test (GHT) sectors, and point-by-point retinal sensitivities were compared between LUXIE and HFA3. All participants were asked to fill out a post-test user survey. Results: Thirty-eight participants with 65 eyes were enrolled. LUXIE demonstrated good correlations with HFA3 in global (r = 0.81), superior hemifield (r = 0.77), superonasal, superotemporal, and inferonasal quadrants (r = 0.80, 0.78, 0.80). The user survey showed that participants were more satisfied with LUXIE in operating difficulty, comfortability, time perception, concentration, and overall satisfaction. Conclusions: LUXIE demonstrated good correlations with HFA3. Fixation loss could be eliminated in LUXIE with the eye-tracking system. The application of virtual reality devices such as the HTC Vive Pro Eye makes telemedicine and even home-based self-screening visual field tests possible. Key Messages: 1. Virtual reality perimetry is a developing technology that has the potential in telemedicine, and home self-screening visual field tests. 2. LUXIE demonstrated good correlations with Humphrey Field Analyzer 3 in visual field retinal sensitivities.

8 August 2015 in BMC Ophthalmology
Verified
Journal Article
Open access
PDF file
SWShiu-Chen Wu
Shiu-Chen Wu
YLYung-Sung Lee
Yung-Sung Lee
Wei-Chi WuWei-Chi Wu
Wei-Chi Wu
SCShirley H L Chang
Shirley H L Chang
Pupil dilation is a known risk factor for acute angle-closure glaucoma. Regular retinal evaluation is necessary for retinopathy of prematurity (ROP) cases. An acute attack of angle-closure glaucoma following pupil dilation in regressed ROP has never been reported. A five-year-old girl presented to the hospital for a routine retina check-up. The patient was born prematurely with a gestation age of 27 weeks and a body weight of 980 grams. She had a history of stage 4A ROP in the right eye and received scleral buckling. After pupil dilation with 1 % tropicamide and 10 % phenylephrine for retinal examination, acute elevation of intraocular pressure (IOP) was observed in the right eye. Her IOP remained over 50 mmHg in the right eye even under treatment with oral acetazolamide and maximal tolerated doses of topical anti-glaucoma medications. Ultrasound biomicroscopy (UBM) showed that the angle in the right eye was closed 360 degrees circumferentially. In order to lower IOP, trabeculectomy with mitomycin C (0.2 mg/cc) was performed under general anesthesia. Postoperatively, the cornea became clear, the filtering bleb functioned well, and IOP returned to normal values. In the two-year follow-up, IOP was kept around 15 mmHg without anti-glaucoma medications. Although mild lens opacity was noted, her postoperative VA remained 20/200 in the right eye. Regular retinal evaluation will be necessary for the increasing number of ROP cases to be seen in the future. Ophthalmologists should bear in mind that pupil dilation for a retina check-up could result in acute angle-closure glaucoma in ROP patients.

14 October 2020 in British Journal of Ophthalmology
Verified
Journal Article
Closed access
PDF file
YLYung-Sung Lee
Yung-Sung Lee
WTWee-Min Teh
Wee-Min Teh
HTHsiao-Jung Tseng
Hsiao-Jung Tseng
YHYih-Shiou Hwang
Yih-Shiou Hwang
CLChi-Chun Lai
Chi-Chun Lai
Wei-Chi WuWei-Chi Wu
Wei-Chi Wu
Aims To determine longitudinal differences in foveal thickness in preschool-aged patients with or without a history of type I retinopathy of prematurity (ROP). Methods A study of 201 eyes, including 32 laser±intravitreal bevacizumab (IVB)-treated eyes, 37 IVB-treated eyes, 14 spontaneously regressed ROP eyes, and 118 age-matched controls were enrolled in this study. The retinal thicknesses (full, inner and outer) were measured in the foveal area at 6-month intervals four consecutive times by optical coherence tomography. Results The foveal thicknesses among the four groups were similar at all four visits (all p>0.05) after gestational age (GA) adjustment and remained similar with no differences after the full retinal thickness was divided into inner and outer thicknesses (all p>0.05). The full and outer foveal thicknesses of premature children increased over time (0.17 μm/month and 0.17 μm/month; p=0.0001 and 0.0003, respectively), but the inner foveal thickness remained unchanged with time (0.002 μm/month; p=0.09). Moreover, the positive correlation with best-corrected visual acuity was stronger for outer foveal thickness than for inner foveal thickness (γ=0.281, p<0.0001 and γ=0.181, p<0.0001, respectively). Conclusion The thickness of fovea in laser±IVB-treated, IVB-treated, regressed ROP and preterm eyes showed no difference after GA adjustment. The whole and outer foveal thicknesses increased with time in preschool-aged children over a 1.5-year follow-up period, but the inner foveal thickness remained unchanged with time.

1 January 2021 in Journal of Ophthalmology
Verified
Journal Article
Open access
PDF file
WSWei-Wen Su
Wei-Wen Su
SHShian-Sen Hsieh
Shian-Sen Hsieh
MSMing-Hui Sun
Ming-Hui Sun
HCHenry Shen-Lih Chen
Henry Shen-Lih Chen
YLYung-Sung Lee
Yung-Sung Lee
HTHsiao-Jung Tseng
Hsiao-Jung Tseng
Purpose . To evaluate Humphrey visual field (VF) progression rate before and after cataract surgery in patients with open‐angle glaucoma (OAG) and angle‐closure glaucoma (ACG). Methods . After reviewing all records in our Humphrey VF database from July 1, 2001, to December 31, 2018, eyes of OAG and ACG that had received uncomplicated phacoemulsification with intraocular lens implantation during the period and had been followed up regularly for more than one year with ≥3 reliable VF tests before and after cataract surgery, respectively, were enrolled. The VF progression rate, visual acuity, and intraocular pressure (IOP) before and after cataract surgery were compared. Results . Seventy‐seven eyes (OAG: 51; ACG: 26) from 60 patients were enrolled. The mean preoperative and postoperative follow‐up durations were 4.89 ± 2.70 and 5.48 ± 2.30 years in the OAG group and 5.14 ± 3.31 and 5.97 ± 2.35 years in the ACG group. IOP and visual acuity significantly improved postoperatively in both groups. In the OAG group, there was no significant change in the VF progression rate (pre‐op: −0.39 ± 0.94 dB/year; post‐op: −0.47 ± 0.72 dB/year) ( P = 0.619), whereas, in the ACG group, the rate significantly flattened after surgery from −1.39 ± 1.31 dB/year to −0.34 ± 0.64 dB/year ( P = 0.003). Conclusions . The VF progression rate did not differ between preoperative and postoperative eyes with OAG, but those with ACG exhibited rapid VF decline preoperatively, which was significantly flattened postoperatively.