Sebastian Ebel

Dr. Sebastian Ebel

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2019 in The International Journal of Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
Sebastian EbelSebastian Ebel
Sebastian Ebel
SGSebastian Gottschling
Sebastian Gottschling
MWMaria Teodora TA Wetshcherek
Maria Teodora TA Wetshcherek
MGMatthias Grothoff
Matthias Grothoff
IDIngo Daehnert
Ingo Daehnert
CLChristian Lücke
Christian Lücke
To compare contrast-enhanced magnetic resonance angiography (ceMRA) and 3D steady-state free precession (SSFP) during systole and diastole for assessment of the right ventricle outflow tract (RVOT) in patients considered for percutaneous pulmonary valve implantation (PPVI) after tetralogy of Fallot (TOF) repair. We retrospectively evaluated 89 patients (male: 45, mean age 19 ± 8 years), who underwent cardiac-MRI after surgical TOF-repair. Datasets covering the whole heart in systole and diastole were acquired using ECG-gated 3D SSFP and non-gated ceMRA. Measurements were performed in SSFP-sequences and in ceMRA in the narrowest region of the RVOT to obtain the minimum, maximum and effective diameter. Invasive balloon sizing as the gold standard was available in 12 patients. The minimum diameter in diastolic SSFP, systolic SSFP and ceMRA were 21.4 mm (± 6.1 mm), 22.6 mm (± 6.2 mm) and 22.6 mm (± 6.0 mm), respectively. Maximum diameter was 29.9 mm (± 9.5 mm), 30.0 mm (± 7.0 mm) and 28.8 mm (± 8.1 mm) respectively. The effective diameter was 23.2 mm (± 5.7 mm), 27.4 mm (± 6.7 mm) and 24.4 mm (± 6.2 mm), differing significantly between diastole and systole (p < 0.0001). Measurements in ECG-gated SSFP showed a better inter- and intraobserver variability compared to measurements in non-ECG-gated ceMRA. Comparing invasive balloon sizing with our analysis, we found the highest correlation coefficients for the maximum and effective diameter measured in systolic SSFP (R = 0.99 respectively). ECG-gated 3D SSFP enables the identification and characterization of a potential landing zone for PPVI. The maximum and effective systolic diameter allow precise sizing for PPVI. Patients with TOF-repair could benefit from cardiac MRI before PPVI.

25 May 2022 in European Radiology
Verified
Journal Article
Open access
PDF file
Sebastian EbelSebastian Ebel
Sebastian Ebel
AKAlexander Kühn
Alexander Kühn
AAAbhinav Aggarwal
Abhinav Aggarwal
BKBenjamin Köhler
Benjamin Köhler
BBBenjamin Behrendt
Benjamin Behrendt
MGMatthias Gutberlet
Matthias Gutberlet
Objectives: 4D flow MRI enables quantitative assessment of helical flow. We sought to generate normal values and elucidate changes of helical flow (duration, volume, length, velocities and rotational direction) and flow jet (displacement, flow angle) as well as wall shear stress (WSS). Methods: We assessed the temporal helical existence (THEX), maximum helical volume (HVmax), accumulated helical volume (HVacc), accumulated helical volume length (HVLacc), maximum forward velocity (maxVfor), maximum circumferential velocity (maxVcirc), rotational direction (RD) and maximum wall shear stress (WSS) as reported elsewhere using the software tool Bloodline in 86 healthy volunteers (46 females, mean age 41 ± 13 years). Results: WSS decreased by 42.1% and maxVfor by 55.7% across age. There was no link between age and gender regarding the other parameters. Conclusion: This study provides age-dependent normal values regarding WSS and maxVfor and age- and gender-independent normal values regarding THEX, HVmax, HVacc, HVLacc, RD and maxVcirc. Key Points: • 4D flow provides numerous new parameters; therefore, normal values are mandatory. • Wall shear stress decreases over age. • Maximum helical forward velocity decreases over age.

20 August 2024 in Journal of Educational Evaluation for Health Professions
Verified
Journal Article
Open access
Sebastian EbelSebastian Ebel
Sebastian Ebel
CEConstantin Ehrengut
Constantin Ehrengut
Timm DeneckeTimm Denecke
Timm Denecke
HGHolger Gößmann
Holger Gößmann
ABAnne Bettina Beeskow
Anne Bettina Beeskow
Purpose: This study aimed to determine whether ChatGPT-4o, a generative artificial intelligence (AI) platform, was able to pass a simulated written European Board of Interventional Radiology (EBIR) exam and whether GPT-4o can be used to train medical students and interventional radiologists of different levels of expertise by generating exam items on interventional radiology.Methods: GPT-4o was asked to answer 370 simulated exam items of the Cardiovascular and Interventional Radiology Society of Europe (CIRSE) for EBIR preparation (CIRSE Prep). Subsequently, GPT-4o was requested to generate exam items on interventional radiology topics at levels of difficulty suitable for medical students and the EBIR exam. Those generated items were answered by 4 participants, including a medical student, a resident, a consultant, and an EBIR holder. The correctly answered items were counted. One investigator checked the answers and items generated by GPT-4o for correctness and relevance. This work was done from April to July 2024.Results: GPT-4o correctly answered 248 of the 370 CIRSE Prep items (67.0%). For 50 CIRSE Prep items, the medical student answered 46.0%, the resident 42.0%, the consultant 50.0%, and the EBIR holder 74.0% correctly. All participants answered 82.0% to 92.0% of the 50 GPT-4o generated items at the student level correctly. For the 50 GPT-4o items at the EBIR level, the medical student answered 32.0%, the resident 44.0%, the consultant 48.0%, and the EBIR holder 66.0% correctly. All participants could pass the GPT-4o-generated items for the student level; while the EBIR holder could pass the GPT-4o-generated items for the EBIR level. Two items (0.3%) out of 150 generated by the GPT-4o were assessed as implausible.Conclusion: GPT-4o could pass the simulated written EBIR exam and create exam items of varying difficulty to train medical students and interventional radiologists.

26 February 2019 in European Radiology Experimental
Verified
Journal Article
Open access
PDF file
Sebastian EbelSebastian Ebel
Sebastian Ebel
LHLisa Hübner
Lisa Hübner
BKBenjamin Köhler
Benjamin Köhler
SKSiegfried Kropf
Siegfried Kropf
BPBernhard Preim
Bernhard Preim
MGMatthias Gutberlet
Matthias Gutberlet
Four-dimensional (4D) flow magnetic resonance imaging (MRI) sequences with advanced parallel imaging have the potential to reduce scan time with equivalent image quality and accuracy compared with standard two-dimensional (2D) flow MRI. We compared 4D flow to standard 2D flow sequences using a constant and pulsatile flow phantom at 3 T. Two accelerated 4D flow sequences (GRAPPA2 and k-t-GRAPPA5) were evaluated regarding the concordance of flow volumes, flow velocities, and reproducibility as well as dependency on measuring plane and velocity encoding (Venc). The calculated flow volumes and peak velocities of the phantom were used as reference standard. Flow analysis was performed using the custom-made software “Bloodline”. No significant differences in flow volume were found between the 2D, both 4D flow MRI sequences, and the pump reference (p = 0.994) or flow velocities (p = 0.998) in continuous and pulsatile flow. An excellent correlation (R = 0.99–1.0) with a reference standard and excellent reproducibility of measurements (R = 0.99) was achieved for all sequences. A Venc overestimated by up to two times had no impact on flow measurements. However, misaligned measuring planes led to an increasing underestimation of flow volume and mean velocity in 2D flow accuracy, while both 4D flow measurements were not affected. Scan time was significantly shorter for k-t-GRAPPA5 (1:54 ± 0:01 min, mean ± standard deviation) compared to GRAPPA2 (3:56 ± 0:02 min) (p = 0.002). Both 4D flow sequences demonstrated equal agreement with 2D flow measurements, without impact of Venc overestimation and plane misalignment. The highly accelerated k-t-GRAPPA5 sequence yielded results similar to those of GRAPPA2.

14 June 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Sebastian EbelSebastian Ebel
Sebastian Ebel
JDJosefin Dufke
Josefin Dufke
BKBenjamin Köhler
Benjamin Köhler
BPBernhard Preim
Bernhard Preim
SRSusan Rosemeier
Susan Rosemeier
MGMatthias Gutberlet
Matthias Gutberlet
To compare two broadly used 4D-flow- with a 2D-flow-sequence in healthy volunteers, regarding absolute flow parameters, image quality (IQ), and eddy current correction (ECC). Forty volunteers (42 ± 11.8 years, 22 females) were examined with a 3T scanner. Thoracic aortic flow was assessed using a 3D-T2w-SPACE-STIR-sequence for morphology and two accelerated 4D-flow sequences for comparison, one with k-t undersampling and one with standard GRAPPA parallel-imaging. 2D-flow was used as reference standard. The custom-made software tool Bloodline enabled flow measurements for all analyses at the same location. Quantitative flow analyses were performed with and without ECC. One reader assessed pathline IQ (IQ-PATH) and occurrence of motion artefacts (IQ-ART) on a 3-point grading scale, the higher the better. k-t GRAPPA allowed a significant mean scan time reduction of 46% (17:56 ± 5:26 min vs. 10:40 ± 3:15 min) and provided significantly fewer motion artefacts than standard GRAPPA (IQ-ART 1.57 ± 0.55 vs. 0.84 ± 0.48; p < 0.001). Neither 4D-flow sequence significantly differed in flow volume nor peak velocity results with or without ECC. Nevertheless, the correlation between both 4D-flow sequences and 2D-flow was better with ECC; the k-t GRAPPA sequence performed best (R = 0.96 vs. 0.90). k-t GRAPPA 4D-flow was not inferior to a standard GRAPPA-sequence, showed fewer artefacts, comparable IQ and was almost two-fold faster.

19 February 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Sebastian EbelSebastian Ebel
Sebastian Ebel
JDJosefin Dufke
Josefin Dufke
BKBenjamin Köhler
Benjamin Köhler
BPBernhard Preim
Bernhard Preim
BBBenjamin Behrendt
Benjamin Behrendt
MGMatthias Gutberlet
Matthias Gutberlet
4D flow MRI enables quantitative assessment of helical flow. Current methods are susceptible to noise. To evaluate helical flow patterns in healthy volunteers and patients with bicuspid aortic valves (BAV) at 1.5 T and 3 T using pressure-based helix-extraction in 4D flow MRI. Two intraindividual 4D flow MRI examinations were performed at 1.5 T and 3 T in ten healthy volunteers (5 females, 32 ± 3 years) and 2 patients with BAV using different acceleration techniques (kt-GRAPPA and centra). Several new quantitative parameters for the evaluation of volumes [ml], lengths [mm] as well as temporal parameters [ms] of helical flow were introduced and analyzed using the software tool Bloodline. We found good correlations between measurements in volunteers at 1.5 T and 3 T regarding helical flow volumes (R = 0.98) and temporal existence (R = 0.99) of helices in the ascending aorta. Furthermore, we found significantly larger (11.7 vs. 77.6 ml) and longer lasting (317 vs. 769 ms) helices in patients with BAV than in volunteers. The assessed parameters do not depend on the magnetic field strength used for the acquisition. The technique of pressure-based extraction of 4D flow MRI pattern is suitable for differentiation of normal and pathological flow.