Hongling Zhu

Hongling Zhu


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 February 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
SRShaolin Ran
Shaolin Ran
XYXiaoyun Yang
Xiaoyun Yang
MLMing Liu
Ming Liu
YZYong Zhang
Yong Zhang
CCCheng Cheng
Cheng Cheng
YYYe Yuan
Ye Yuan
The accurate electrocardiogram (ECG) interpretation is important for several potentially life-threatening cardiac diseases. Recently developed deep learning methods show their ability to distinguish some severe heart diseases. However, since deep neural network requires a high cost on memory consumption and computation, implementation scenarios of these interpretation methods are constrained to nonportable devices. Few commercial portable devices only have heartbeat detection ability, and therefore, only a few simple cardiac diseases can be diagnosed. In this article, to achieve diagnosing a wide range of cardiac diseases and continuous monitoring, a homecare-oriented ECG diagnosis platform is designed based on a large-scale multilabel deep conventional neural network. The accuracy of the proposed neural network model is guaranteed by our constructed large-scale ECG dataset, which is comprised of 206 468 standard 12-lead ECG recordings from 89 488 patients, with respect to 26 types of most common heart rhythms and conduction abnormalities. Meanwhile, targeting lightweight homecare or wearable applications, algorithm-hardware co-optimization is conducted to accelerate the model computation on an embedded platform with field-programmable gate array (FPGA) for continuous monitoring. Channel-level pruning and parameters quantization strategy are employed to optimize the network, and a reconfigurable accelerator hardware architecture is designed to accelerate the convolution computation on FPGA. The final quantified model achieved a promising $F_{1}$ score of 0.913% and 86.7% exact match ratio, in which parameters and floating-point operations per second (FLOPs) are significantly penalized compared to the original large-scale model. Real-time analysis is performed. Specifically, the average processing time for each ECG record is 2.895 s, and it can be applied to homecare or portable ECG diagnosis devices for continuous monitoring.

27 October 2021 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
HZHongling Zhu
Hongling Zhu
JLJinsheng Lai
Jinsheng Lai
BLBingqiang Liu
Bingqiang Liu
ZWZiyuan Wen
Ziyuan Wen
YXYulong Xiong
Yulong Xiong
HZHesong Zeng
Hesong Zeng

4 September 2023 in Thrombosis Journal
Verified
Journal Article
Open access
PDF file
KZKexin Zhang
Kexin Zhang
YJYao Jiang
Yao Jiang
HZHesong Zeng
Hesong Zeng
HZHongling Zhu
Hongling Zhu
Cardiocerebrovascular diseases (CVDs) are the leading cause of death worldwide, consuming huge healthcare budget. For CVD patients, the prompt assessment and appropriate administration is the crux to save life and improve prognosis. Thrombolytic therapy, as a non-invasive approach to achieve recanalization, is the basic component of CVD treatment. Still, there are risks that limits its application. The objective of this review is to give an introduction on the utilization of thrombolytic therapy in cardiocerebrovascular blockage diseases, including coronary heart disease and ischemic stroke, and to review the development in risk assessment of thrombolytic therapy, comparing the performance of traditional scales and novel artificial intelligence-based risk assessment models.

21 July 2023 in International Journal of Human–Computer Interaction
Verified
Journal Article
Closed access
XHXin He
Xin He
XZXi Zheng
Xi Zheng
HDHuiyuan Ding
Huiyuan Ding
YLYixuan Liu
Yixuan Liu
HZHongling Zhu
Hongling Zhu

27 June 2020 in Annals of Noninvasive Electrocardiology
Verified
Journal Article
Open access
PDF file
YXYulong Xiong
Yulong Xiong
HZHongling Zhu
Hongling Zhu
Idiopathic ventricular arrhythmia (IVA) is a term used to describe a spectrum of ventricular arrhythmia without structural heart disease (SHD). IVAs contain premature ventricular contractions (PVCs), nonsustained monomorphic ventricular tachycardia (VT), and sustained VT. Electrocardiography is a fundamental and important tool to diagnose and localize IVAs. More detailed, IVAs originating from different origins exhibit characterized ECGs due to their specific anatomic backgrounds. As catheter ablation becomes widely used to eliminate these arrhythmias, its high success rate is based on accurate localization of their origins. Therefore, these ECG characteristics show great importance for precise localization of their origins and subsequently successful ablation. This review aims to sum up ECG characteristics of IVAs based on anatomy and give brief introduction of mechanisms and treatment of IVAs.

26 September 2024 in NEJM AI
Verified
Journal Article
Closed access
HZHongling Zhu
Hongling Zhu
YJYinuo Jiang
Yinuo Jiang
CCCheng Cheng
Cheng Cheng
JWJingyi Wang
Jingyi Wang
LZLinghao Zhu
Linghao Zhu
XYXiaoyun Yang
Xiaoyun Yang